文献速递胸部技术与安全DR

夜班疲劳对住院医师胸片诊断表现及AI辅助的影响

From dusk till dawn?-Night shift-induced fatigue, diagnostic performance, and AI assistance in chest radiography.
PubMed 文献 · Eur Radiol · 2026-10-22

前瞻性个体内读片研究纳入10名放射科住院医师,在夜班前后各读33张胸片,用眼动追踪界定疲劳。6人疲劳,其诊断准确率(κ)从0.71降至0.61,AI辅助未显著提升准确率,但缩短了非疲劳者的报告时间。

要点

  • 夜班后疲劳可降低胸片诊断准确率,但报告速度不变,需警惕漏诊风险。
  • 眼动追踪主序列斜率下降≥5%可用于客观识别疲劳状态。
  • 本研究所用AI模型未能恢复疲劳导致的诊断准确率下降。

关键影像表现/征象

  • 6名住院医师被归类为疲劳,其班后诊断准确率显著下降(κ从0.71±0.05降至0.61±0.10,p<0.001),注视持续时间(p=0.010)和眼跳次数(p=0.015)减少。
  • 非疲劳读者准确率下降幅度较小(κ从0.72±0.03降至0.65±0.03,p=0.037)。
  • 报告时间在班前班后保持稳定(p≥0.463)。
  • AI辅助未显著改善诊断准确率(Δκ=0.03-0.04;p≥0.525);疲劳读者报告时间数值缩短(Δ6.3秒;p=0.122),非疲劳读者显著缩短(Δ9.9秒;p=0.031)。

诊断标准与关键数值

  • 疲劳定义:眼跳主序列斜率在班前与班后会话间下降≥5%。
  • 诊断准确率以Cohen's κ对照专家多数投票评估,疲劳读者班后κ=0.61±0.10,非疲劳读者班后κ=0.65±0.03。
  • AI辅助对诊断准确率改善无统计学意义(Δκ=0.03-0.04;p≥0.525)。

临床应用与阅片要点

  • 胸片报告速度正常不能排除疲劳导致的准确率下降,夜班后阅片需警惕诊断错误。
  • 眼动追踪指标(注视持续时间、眼跳次数)可用于客观评估读片者疲劳状态。
  • 本研究所用AI辅助未能补偿疲劳相关准确率损失,不宜依赖AI弥补疲劳影响。

局限性

  • 单中心前瞻性研究,样本量仅10名住院医师。
  • AI辅助评估仅针对特定模型,结论不能推广至其他AI系统。
  • 疲劳定义基于眼动追踪阈值,可能存在分类偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the impact of night shift-induced fatigue on radiology residents' diagnostic performance and to assess whether AI assistance offsets potential performance loss.

MATERIALS AND METHODS: In this prospective intra-individual reader study, ten radiology residents (mean experience: 35 months; three women) interpreted three sets of 33 chest radiographs before and after a first-call on-site night shift. Sessions included two pre-shift readings (morning/afternoon, without AI) and two post-shift readings (morning, with/without AI). Eye tracking captured fixation duration and saccade count, and fatigue was defined as a ≥ 5% reduction in the slope of the saccadic main sequence between pre- and post-shift sessions. Diagnostic accuracy (Cohen's κ vs. expert majority vote), efficiency (mean reporting time per radiograph), eye-tracking metrics, and user surveys were analyzed with generalized linear mixed models and post-hoc Tukey-adjusted pairwise comparisons.

RESULTS: Six of ten radiology residents were classified as fatigued, among whom diagnostic accuracy declined significantly post-shift (from κ = 0.71 ± 0.05 to κ = 0.61 ± 0.10; p < 0.001), with reduced fixation duration (p = 0.010) and saccade count (p = 0.015). Non-fatigued readers showed a smaller decline in accuracy (from κ = 0.72 ± 0.03 to κ = 0.65 ± 0.03; p = 0.037). Reporting times remained stable pre- and post-shift (p ≥ 0.463). AI assistance did not significantly improve diagnostic accuracy (Δκ = 0.03-0.04; p ≥ 0.525). Reporting times were numerically shorter with AI assistance in fatigued readers (Δ6.3 s; p = 0.122) and significantly shorter in non-fatigued readers (Δ9.9 s; p = 0.031). Surveys indicated mental exhaustion and reduced focus in fatigued readers.

CONCLUSION: Night-shift-induced fatigue impaired diagnostic accuracy without slowing reporting speed, raising patient safety concerns. The utilized AI model did not restore pre-shift performance.

KEY POINTS: Question Night-shift-induced fatigue may reduce diagnostic accuracy of radiology residents in chest radiography, yet its objective quantification and the compensatory potential of AI assistance remain unclear. Findings Fatigue, based on eye-tracking measurements of oculomotor efficiency, reduced diagnostic accuracy after night shifts without slowing reporting speed; AI assistance did not significantly improve accuracy. Clinical relevance Night-shift-induced fatigue can lower diagnostic accuracy in chest radiography despite unchanged reporting speed, posing patient-safety risks. The AI model used in this study cannot fully compensate for fatigue-related performance decline.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Siepmann RM, Khoobi M, von der Stück MS, et al. From dusk till dawn?-Night shift-induced fatigue, diagnostic performance, and AI assistance in chest radiography. Eur Radiol. 2026. PMID: 42918884. doi:10.1007/s00330-026-12969-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。