文献速递骨肌胸部CT

基于常规胸部CT无体模定量CT来源的胸椎体积骨密度机会性筛查髋部骨质疏松:多中心回顾性研究

Opportunistic screening of hip osteoporosis using Phantom-Less quantitative CT-Derived thoracic volumetric BMD from routine chest CT: A Multicentre, retrospective study.
PubMed 文献 · Eur J Radiol · 2026-10-11

多中心回顾性纳入568例60岁以上同时行非增强胸部CT和DXA的患者,用无体模定量CT系统测量胸椎体积骨密度(Th-vBMD)。以髋部DXA T值为参考,Th-vBMD诊断髋部骨质疏松的AUC为0.873,最佳阈值85.4 mg/cm3,敏感度0.851、特异度0.864;诊断髋部骨量减少的阈值为120.7 mg/cm3,敏感度0.860、特异度0.811。

要点

  • 胸部CT测得Th-vBMD≤85.4 mg/cm3可作为髋部骨质疏松的独立预测指标(校正OR 26.70)。
  • 诊断髋部骨质疏松阈值85.4 mg/cm3,敏感度0.851、特异度0.864。
  • 诊断髋部骨量减少阈值120.7 mg/cm3,敏感度0.860、特异度0.811。

关键影像表现/征象

  • Th-vBMD由无体模定量CT(PL-QCT)系统从常规胸部CT测量获得,无需体模。
  • 研究以髋部DXA T值为参考标准,比较Th-vBMD的诊断性能。

诊断标准与关键数值

  • 诊断髋部骨质疏松:Th-vBMD阈值85.4 mg/cm3,AUC 0.873(95%CI 0.837-0.910),敏感度0.851,特异度0.864。
  • 诊断髋部骨量减少:Th-vBMD阈值120.7 mg/cm3,敏感度0.860,特异度0.811。
  • Th-vBMD≤85.4 mg/cm3为髋部骨质疏松独立预测因子,校正OR 26.70(95%CI 16.3-45.0,p<0.001)。
  • 研究人群髋部骨质疏松患病率36.3%,髋部骨量减少患病率42.6%。

临床应用与阅片要点

  • 对60岁以上患者行常规胸部CT时,可机会性测量Th-vBMD辅助识别髋部骨质疏松风险。
  • Th-vBMD≤85.4 mg/cm3提示髋部骨质疏松高风险,可建议进一步DXA评估或干预。
  • Th-vBMD 85.4–120.7 mg/cm3提示髋部骨量减少可能,需结合临床随访。

局限性

  • 本研究为回顾性设计。
  • 诊断模型仅行内部验证(500次bootstrap重采样),未行外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To develop and validate diagnostic thresholds for thoracic volumetric bone mineral density (vBMD) derived from routine chest CT scans, and to evaluate the performance of this metric for opportunistic screening of hip osteoporosis (hOP) and hip osteopenia in adults aged 60 years and older.

METHODS: This multicenter retrospective study enrolled 568 patients aged 60 years and older who underwent both non-contrast chest computed tomography (CT) and dual-energy X-ray absorptiometry (DXA). Thoracic quantitative CT-derived volumetric bone mineral density (Th-vBMD) was measured using a phantomless quantitative CT (PL-QCT) system. The robustness of the diagnostic model was evaluated through internal validation, including 500-iteration bootstrap resampling. The diagnostic performance of Th-vBMD was compared against the reference hip DXA T-score.

RESULTS: A total of 568 patients were included. The prevalence of hOP and hip osteopenia was 36.3 % and 42.6 %, respectively. Th-vBMD demonstrated performance with an area under the curve (AUC) of 0.873 (95 % CI: 0.837-0.910). The optimal Th-vBMD threshold for hOP was 85.4 mg/cm3, sensitivity 0.851 and specificity 0.864. The optimal threshold for hip osteopenia was 120.7 mg/cm3, sensitivity: 0.860 and specificity: 0.811. Logistic regression identified Th-vBMD ≤ 85.4 mg/cm3 as an independent predictor of hOP (adjusted OR: 26.70; 95 % CI: 16.3-45.0; p < 0.001).

CONCLUSION: This study establishes and validates Th-vBMD thresholds derived from routine chest CT for opportunistic hOP screening in elderly. This cost-effective strategy leverages clinical imaging data to identify individuals at osteoporosis risk, facilitating intervention and advancing osteoporosis prevention.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yu Z, Lai J, Wu B, et al. Opportunistic screening of hip osteoporosis using Phantom-Less quantitative CT-Derived thoracic volumetric BMD from routine chest CT: A Multicentre, retrospective study. Eur J Radiol. 2026. PMID: 42950524. doi:10.1016/j.ejrad.2026.113302

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。