光子计数CT前庭导水管轨迹分析用于评估梅尼埃病内分型与听力损失
本研究回顾性纳入106例(212耳)梅尼埃病患者,行颞骨光子计数CT和3.0-T 3D-FLAIR MRI,评估前庭导水管形态学参数对内分型识别和听力损失的关联。前庭导水管可见度分级识别发育不良型AUC为0.860,形态联合中点宽度区分退变型AUC为0.784,ATVA是纯音平均听阈的独立预测因子。
要点
- 前庭导水管可见度分级可识别发育不良型内分型,AUC 0.860。
- 前庭导水管形态联合中点宽度可区分退变型内分型,AUC 0.784。
- ATVA是纯音平均听阈的独立预测因子(β=0.238,p=0.023)。
关键影像表现/征象
- 前庭导水管可见度分级用于识别发育不良型内分型。
- 前庭导水管形态与中点宽度联合用于区分退变型内分型。
诊断标准与关键数值
- 前庭导水管可见度分级识别发育不良型内分型:AUC 0.860(留一患者交叉验证,0.812)。
- 前庭导水管形态联合中点宽度区分退变型内分型:AUC 0.784(留一患者交叉验证,0.736)。
- ATVA为纯音平均听阈独立预测因子:β=0.238,p=0.023。
- 观察者间一致性优秀:ICC 0.84-0.91。
临床应用与阅片要点
- 可依据前庭导水管可见度分级在阅片时提示发育不良型内分型。
- 结合前庭导水管形态与中点宽度有助于区分退变型内分型。
- 测量ATVA可能辅助评估听力损失严重程度。
局限性
- 回顾性研究设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Ménière's disease (MD) is a heterogeneous inner ear disorder, and imaging-based endotype identification may inform prognosis and personalized management. The vestibular aqueduct (VA) is a candidate imaging biomarker, and photon-counting CT (PCCT) offers high-resolution depiction of temporal bone microanatomy. This study evaluated PCCT-derived VA morphometric parameters as imaging biomarkers for MD endotype identification and hearing loss assessment.
METHODS: In this retrospective study, 106 patients (212 ears) underwent temporal bone PCCT and 3.0-T 3D-FLAIR MRI. PCCT parameters included angular trajectory of the VA (ATVA), VA visibility grade, morphologic subtype, midpoint width, VA length, and posterior semicircular canal-posterior fossa distance. Two neuroradiologists independently evaluated all images. Diagnostic performance for six clinically motivated tasks was assessed by AUC with leave-one-patient-out cross-validation (LOPOCV); associations with pure-tone average (PTA) were evaluated by multivariable linear regression with cluster-robust standard errors.
RESULTS: Interobserver agreement was excellent (ICC, 0.84-0.91). VA visibility grading identified the hypoplastic endotype with an AUC of 0.860 (LOPOCV, 0.812); combined VA morphology and midpoint width distinguished the degenerated endotype with an AUC of 0.784 (LOPOCV, 0.736). Multivariable regression identified ATVA as an independent PTA predictor (β = 0.238, p = 0.023).
CONCLUSIONS: PCCT-derived VA morphometric parameters enabled MD endotype identification despite clinical heterogeneity and were associated with hearing loss severity, supporting their potential role as imaging biomarkers for MD management.
引用
- Wang J, Han Y, Xiang Y, et al. Photon-counting CT based vestibular aqueduct trajectory analysis for the assessment of Ménière's disease endotypes and hearing loss. Eur J Radiol. 2026. PMID: 42874222. doi:10.1016/j.ejrad.2026.113301
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。