ESR要点:儿童神经影像的无钆对比剂实践建议
欧洲神经放射学会基于文献和专家经验发布实践建议,提出在儿童神经影像中应个体化评估钆对比剂使用,权衡风险与获益。文中列出可重新审视钆对比剂使用的常见情形,并建议在神经放射科医生与临床医生密切沟通下考虑替代策略,同时需要前瞻性开发新序列以提高无增强MR的准确性。
要点
- 儿童神经影像使用钆对比剂应个体化评估,有文献支持时参照证据权衡风险获益。
- 部分常见情形可考虑替代策略,需神经放射科与临床密切沟通。
- 需前瞻性开发新序列以提高无增强MR成像准确性、扩大无钆检查。
核心结论
- 儿童神经影像中钆对比剂的使用应基于每个病例个体化评估,并尽可能有特定文献数据支持,以平衡风险与获益、改善患者管理和结局。
研究设计与样本
- 本文为欧洲神经放射学会发布的实践建议,基于近期文献综述和大型机构专家日常实践经验,属于简洁综述与专家意见。
临床应用与阅片要点
- 日常阅片和报告儿童神经MR时,应逐例评估钆对比剂是否可能带来真实且实质的潜在获益。
- 对文中提及的钆对比剂使用常见但并非严格循证的情形,可批判性重新考虑是否需要增强。
- 在神经放射科医生与临床医生密切沟通下,部分病例可考虑钆对比剂的替代策略。
局限性
- 本文为基于文献和专家经验的意见性综述,非系统评价或前瞻性研究。
- 文中指出部分常见实践并非严格循证,推荐意见受专家日常经验影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Gadolinium-based contrast agents (GBCA) have been central to magnetic resonance neuroimaging, enhancing diagnostic sensitivity and accuracy, in both adults and children. However, their increasingly widespread use has raised concerns, as evidence exists of gadolinium retention in brain tissue after repeated use. This paper outlines some updated strategies to reduce GBCA administration in pediatric neuroradiology, based on both recent literature and the authors' clinical experience. This paper, therefore, should be considered as a concise review of the main literature data and the opinion of a group of experts in the field, based on their daily practice in large institutions. We mention those most frequent conditions where the usage of GBCA often represents a longstanding, albeit "not strictly evidence-based," common practice which can be critically reconsidered. The use of GBCA in pediatric neuroimaging should be considered carefully based on each case scenario, evaluating if GBCA may provide real and substantial potential benefits to patient management and outcome. KEY POINTS: The use of GBCA in pediatric neuroimaging should be carefully evaluated by the pediatric neuroradiologist on an individual basis, and it should also be supported by specific literature data if present, so as to balance risks and benefits and to improve patient management and outcome. Possible alternative strategies to the use of GBCA may be considered in some cases under a close relationship between pediatric neuroradiologists and clinicians. Prospective development of new sequences is needed to improve unenhanced MR imaging accuracy and expand "Gd-free" examinations.
引用
- Righini A, Löbel U, Galijasevic M, et al. ESR Essentials: "Gadolinium-free" pediatric neuroimaging-practice recommendations by the European Society of Neuroradiology. Eur Radiol. 2026. PMID: 42944874. doi:10.1007/s00330-026-12973-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。