文献速递神经外周血管MR

深度学习加速3D血管壁MRI:Sonic DL大幅缩短扫描时间的前瞻性评估

Deep Learning-Accelerated 3D Vessel Wall MRI: Prospective Evaluation of Sonic DL with Substantial Scan Time Reduction.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-08-17

前瞻性随机交叉研究纳入30例患者,对比传统3D血管壁MRI(加速因子3,9分15秒)与Sonic DL协议(加速因子10,5分20秒)。Sonic DL缩短42%扫描时间,图像质量各参数均达非劣效,79个血管壁病变的检测和增厚模式协议间完全一致(κ=1.00),对比增强一致性优秀(κ=0.89),CNR无显著差异,脑脊液抑制更优。

要点

  • Sonic DL将3D血管壁MRI扫描时间从9分15秒缩短至约5分20秒,图像质量非劣效。
  • 病变检测和管壁增厚模式(偏心 vs 同心)协议间完全一致(κ=1.00),增强一致性优秀(κ=0.89)。
  • 10倍加速下CNR保持可比(P=0.95),且脑脊液抑制更优(P=0.002)。

关键影像表现/征象

  • Sonic DL协议下脑脊液抑制优于传统协议(P=0.002)。
  • 共识别79个血管壁病变,其中58个偏心性增厚、21个同心性增厚。
  • 管腔-背景对比噪声比(CNRLB)两种协议间无显著差异(P=0.95)。

诊断标准与关键数值

  • 图像质量采用4点Likert量表(1分优至4分差),非劣效界值预设为+0.5,各参数均值差异的95%CI上限均在界值内。
  • 病变检测协议间一致性κ=1.00,管壁增厚模式一致性κ=1.00,对比增强一致性κ=0.89(P=0.50)。
  • 阅片者间一致性各定性 category κ=0.79-0.88。

临床应用与阅片要点

  • Sonic DL可在约5分钟内完成增强后3D血管壁MRI,适合作为常规加速方案。
  • 病变检测和管壁增厚模式判读与传统协议高度一致,报告时可沿用相同诊断标准。
  • 脑脊液抑制改善有助于提高管壁边界的清晰度。

局限性

  • 研究为单中心前瞻性设计,样本量30例。
  • 仅评估增强后3D血管壁MRI,未涉及平扫或其他序列。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: While 3D vessel wall MRI (VW-MRI) is essential for characterizing vasculopathies, prolonged acquisition times limit its utility by increasing motion susceptibility. We aimed to evaluate Sonic DL, a next-generation AI-accelerated reconstruction technique, for VW-MRI by comparing it with a conventional protocol, using a comprehensive non-inferiority framework with a focus on diagnostic consistency.

MATERIALS AND METHODS: In this prospective, randomized crossover study, 30 patients underwent post-contrast 3D VW-MRI using a conventional protocol (acceleration factor 3; 9:15) and a Sonic DL protocol (acceleration factor 10; 5:20). Three blinded readers evaluated image quality across five parameters (overall quality, vessel wall clarity, lumen suppression, cerebrospinal fluid suppression, and artifacts) and lesion conspicuity using a 4-point Likert scale (1: Excellent to 4: Poor). Non-inferiority was predefined by a margin of +0.5. Inter-protocol agreement for lesion detection, wall thickening patterns (eccentric vs. concentric), and contrast enhancement was also assessed. Quantitative assessment included the lumen-background contrast-to-noise ratio (CNRLB). Inter-reader agreement was assessed using Fleiss' kappa.

RESULTS: Sonic DL achieved a 42% reduction in scan time while maintaining strict non-inferiority across all parameters; the upper limits of the 95% confidence intervals for the mean score differences were all within the predefined margin. A total of 79 vessel wall lesions were identified, with perfect inter-protocol agreement for lesion detection (κ = 1.00) and wall-thickening patterns (κ = 1.00; 58 eccentric, 21 concentric), indicating highly consistent lesion characterization between protocols. Inter-protocol agreement for contrast enhancement was also excellent (κ = 0.89, P = 0.50). Despite 10-fold acceleration, CNRLB remained comparable between protocols (P = 0.95), and Sonic DL improved CSF suppression (P = 0.002). Inter-reader agreement was good to excellent for all qualitative categories (κ = 0.79-0.88).

CONCLUSION: Compared with the conventional protocol, Sonic DL-accelerated VW-MRI maintained non-inferior image quality and lesion assessment while reducing scan time to approximately 5 minutes. Excellent inter-protocol and inter-reader agreement demonstrated consistent lesion characterization across protocols, supporting the feasibility of Sonic DL as an accelerated vessel wall MRI technique.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Ide S, Futatsuya K, Masaki H, et al. Deep Learning-Accelerated 3D Vessel Wall MRI: Prospective Evaluation of Sonic DL with Substantial Scan Time Reduction. AJNR Am J Neuroradiol. 2026. PMID: 42608196. doi:10.3174/ajnr.A9596

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。