文献速递骨肌MR

股骨髋臼撞击综合征放射状MR关节造影结构化报告模板:阅片者间一致性与可重复性

Structured reporting template for radial mr arthrography in femoroacetabular impingement: Inter-reader agreement and reproducibility.
PubMed 文献 · Eur J Radiol · 2026-08-31

本研究开发并验证了用于股骨髋臼撞击综合征(FAI)放射状MR关节造影的结构化报告模板,由两名肌骨放射科医生独立应用于122例疑似FAI患者,仅使用放射状序列评估FAI形态分型、盂唇撕裂位置和软骨病变区域。结果显示关键参数具有优良的阅片者间一致性,支持FAI相关形态和软组织发现的标准化沟通。

要点

  • 结构化模板在FAI形态分型、软骨病变检测和盂唇撕裂定位上均显示优良的阅片者间一致性。
  • 盂唇撕裂在80.3%的患者中出现,其中65.6%位于前上象限(1-2点钟方向)。
  • 仅使用放射状序列即可对FAI关键诊断参数进行可重复的评估。

关键影像表现/征象

  • 盂唇撕裂在80.3%的患者中出现。
  • 65.6%的盂唇撕裂位于前上象限(1-2点钟方向)。

诊断标准与关键数值

  • FAI形态分型(凸轮型、钳型、混合型)的阅片者间一致性κ=0.89(95%CI:0.84-0.93)。
  • 软骨病变检测的阅片者间一致性κ=0.83(95%CI:0.78-0.88)。
  • 盂唇撕裂定位的阅片者间一致性κ=0.97(95%CI:0.93-0.99)。

临床应用与阅片要点

  • 使用结构化模板可提高FAI放射状MR关节造影报告中关键参数(形态分型、盂唇撕裂定位、软骨病变)的阅片者间一致性。
  • 报告盂唇撕裂时建议采用时钟面定位,尤其注意前上象限(1-2点钟方向)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To develop, implement, and validate a standardized structured reporting template for radial MR arthrography in Femoroacetabular impingement (FAI) and to assess its inter-reader agreement for key diagnostic parameters.

METHODS: A structured reporting template was developed based on key FAI imaging biomarkers. For validation, two musculoskeletal radiologists independently applied the template to a pre-existing cohort of 122 patients with suspected FAI who underwent hip arthroscopy. Using only radial sequences, they assessed the FAI morphotype (cam, pincer, mixed), labral tear location (clock-face), and cartilage lesion zone. Inter-reader agreement was quantified using Cohen's kappa (κ) with 95 % confidence intervals.

RESULTS: The application of the structured template demonstrated excellent inter-reader agreement for key parameters. Agreement was excellent for FAI morphotype classification (κ = 0.89; 95 % CI: 0.84-0.93) and cartilage lesion detection (κ = 0.83; 95 % CI: 0.78-0.88), and near-perfect for labral tear localization (κ = 0.97; 95 % CI: 0.93-0.99). Labral tears were present in 80.3 % of patients, with 65.6 % localized to the anterosuperior quadrant (1-2o'clock).

CONCLUSION: The structured reporting template for radial MRA in FAI demonstrates high inter-reader reproducibility across key diagnostic domains, supporting consistent communication of FAI-related morphologic and soft-tissue findings.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nouh MR, Abd El-Kawai MM, Hashem MH, et al. Structured reporting template for radial mr arthrography in femoroacetabular impingement: Inter-reader agreement and reproducibility. Eur J Radiol. 2026. PMID: 42673749. doi:10.1016/j.ejrad.2026.113199

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。