文献速递乳腺乳腺X线

AI模型评估乳腺X线密度用于乳腺癌检测:BreastScreen Norway研究

Mammographic density assessment by an artificial intelligence model for breast cancer detection in BreastScreen Norway.
PubMed 文献 · Eur Radiol · 2026-08-13

该回顾性研究纳入BreastScreen Norway的20万次检查,用商业AI模型自动获取VBD和恶性风险评分,按设备厂商分层。结果显示各VBD组AUC均较高,但VBD 1组最高(0.955)、VBD 4组最低(0.857),且密度分布随厂商和检查/乳腺层面变化。

要点

  • AI风险评分在各密度组均较高,但随密度增加而下降。
  • VBD 4占比在不同设备厂商间差异明显(3.3% vs 6.7%)。
  • 乳腺层面18.5%检查左右乳密度分组不一致。
英文原文(摘要)· 点击展开

OBJECTIVES: The sensitivity of mammographic screening is lower for women with mammographically dense vs fatty breasts. We aimed to explore automated mammographic breast density and malignancy risk scores generated by an artificial intelligence (AI) model for breast cancer detection, stratified by mammography vendor.

MATERIALS AND METHODS: This retrospective study included information from 200,000 examinations within BreastScreen Norway. An automated volumetric breast density (VBD) assessment and risk scores were obtained from a commercial AI model. The continuous VBD output from the AI model was categorized into four groups, VBD 1-4, with 15%, 40%, 40%, and 5% of the examinations in each group for exam level and for right and left breast. Area under the receiver operating characteristic curve (AUC) for breast cancer detection was calculated using a continuous AI risk score. Analyses were performed for exam-level and breast-level measures.

RESULTS: At exam level, the difference in AUC estimates between the VBD groups was statistically significant, with the highest AUC observed for VBD 1 (0.955, 95% CI: 0.937-0.992) and lowest for VBD 4 (0.857, 95% CI: 0.803-0.910). Stratified by vendor, 3.3% and 6.7% were classified as VBD 4 for A vs B. At breast level, 18.5% of the examinations were classified with different VBD groups for the right and left breast.

CONCLUSION: Despite high AUC estimates across all VBD groups and the potential advantages of an automated density assessment, several factors, such as vendor and breast vs exam level, must be carefully considered before implementing automated density measures in screening programs.

KEY POINTS: Question What are the benefits and drawbacks of mammographic density assessment using an AI model for breast cancer detection? Findings The AI model's performance for cancer detection was promising but decreased with increasing density category. Density distribution varied by equipment vendor and examination level. Clinical relevance AI risk assessment at the current examination was promising despite the variation by mammographic density. However, discrepancies in density by equipment vendors and examination level highlight the need for careful consideration before use in risk-stratified screening.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Larsen M, Moshina N, Mikalsen KØ, et al. Mammographic density assessment by an artificial intelligence model for breast cancer detection in BreastScreen Norway. Eur Radiol. 2026. PMID: 42593501. doi:10.1007/s00330-026-12786-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。