文献速递神经CT

双能CT血管成像评估急性分支动脉粥样硬化性疾病相关卒中豆纹动脉形态的病例对照研究

Dual-Energy Computed Tomography Angiography Derived Lenticulostriate Arteries Morphology in Acute Branch Atheromatous Disease-Related Stroke: A Case-Control Study.
PubMed 文献 · Acad Radiol · 2026-08-27

该病例对照研究纳入110例BAD患者及匹配对照,用DE-CTA定量评估豆纹动脉分支数、最大CT值、迂曲度、长度和距离等参数。BAD同侧分支数更少、最大CT值更低、迂曲度更低、长度和距离相关参数更短,半球间差异及百分比差异更大,且这些指标与DWI梗死负荷独立相关。

要点

  • DE-CTA可定量评估豆纹动脉形态,BAD同侧分支数减少、最大CT值降低。
  • 半球间分支数和最大CT值的绝对差及百分比差异增大提示BAD。
  • 豆纹动脉定量指标与DWI梗死层数和最大梗死直径独立相关。

关键影像表现/征象

  • BAD同侧较对侧及对照侧分支数更少、最大CT值更低、迂曲度更低、长度和距离相关参数更短。
  • 对照组半球间各参数无显著差异。
  • BAD组半球间绝对差异和百分比差异均大于对照组。

诊断标准与关键数值

  • 定量指标包括分支数、最大CT值、迂曲度、长度和距离,并计算半球间绝对差异和百分比差异。
  • BAD组同侧分支数和最大CT值及其半球间差异与DWI梗死负荷相关,但与同侧MCA经颅多普勒参数无关。
  • 多因素调整后,较低的同侧分支数和最大CT值及较大的绝对差异和百分比差异仍与BAD、DWI受累层数和最大梗死直径独立相关。

临床应用与阅片要点

  • 阅片时可关注豆纹动脉分支数及最大CT值的双侧不对称,尤其是半球间差异增大。
  • 结合DWI梗死层数和最大梗死直径评估穿支动脉受累负荷。
  • 注意BAD组豆纹动脉改变与同侧MCA经颅多普勒参数无关,提示需直接评估穿支血管。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To quantitatively evaluate lenticulostriate artery (LSA) abnormalities on dual-energy CT angiography (DE-CTA) and examine their associations with branch atheromatous disease (BAD) and infarct burden.

MATERIALS AND METHODS: This case-control study included 110 patients with BAD and matched controls. Quantitative assessment of LSAs included branch count, maximum CT value, tortuosity, length and distance. Interhemispheric absolute differences and percentage interhemispheric differences (PIDs) were calculated. Associations of ipsilateral branch count and maximum CT value, together with their interhemispheric differences and PIDs, with BAD, number of diffusion-weighted imaging (DWI) layers, and maximum infarct diameter were analyzed.

RESULTS: Compared with the contralateral side in BAD and with control sides, ipsilateral sides showed fewer branches, lower maximum CT values, lower tortuosity, and shorter length and distance related parameters, whereas controls showed no significant interhemispheric differences (all P < 0.001). Interhemispheric differences and PIDs were greater in BAD group than in controls (all P < 0.01). In BAD group, ipsilateral branch count and maximum CT value, as well as their interhemispheric differences and PIDs, were associated with DWI infarct burden but not with ipsilateral MCA transcranial Doppler parameters. After multivariable adjustment, lower ipsilateral branch count and maximum CT value, together with greater absolute differences and PIDs of these metrics, remained independently associated with BAD, number of involved DWI layers, and maximum infarct diameter.

CONCLUSION: DE-CTA enables reliable quantification of LSAs morphology and identifies abnormalities associated with BAD and infarct burden, supporting its role as a novel imaging approach for assessing BAD-related perforator involvement.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Yin Y, Wang B, Zhou Z, et al. Dual-Energy Computed Tomography Angiography Derived Lenticulostriate Arteries Morphology in Acute Branch Atheromatous Disease-Related Stroke: A Case-Control Study. Acad Radiol. 2026. PMID: 42648925. doi:10.1016/j.acra.2026.08.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。