CT灌注成像提高临床相关中远端血管闭塞的检出与排除:多阅片者诊断准确性研究
本研究为回顾性多阅片者诊断准确性研究,纳入50例DSA证实的中远端血管闭塞患者和50例无卒中患者,五名不同经验阅片者分三阶段评估NCCT+CTA及联合CTP。结果示联合CTP后敏感度从84%升至100%、特异度从94%升至99%,诊断时间缩短、信心提高、阅片者间一致性显著改善。
要点
- 联合CTP可将DMVO检出敏感度从84%提升至100%,特异度从94%提升至99%。
- CTP使诊断时间从94±24秒缩短至49±24秒,诊断信心中位分从4升至5。
- 阅片者间一致性Fleiss kappa从0.62提升至0.97,各经验水平阅片者均获益。
局限性
- 回顾性设计。
- 单中心研究。
- 样本量较小(共100例)。
- 仅纳入DSA证实的孤立性DMVO且接受血管内治疗的患者,存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Distal/medium vessel occlusions (DMVOs) are frequent and often considered for endovascular therapy. However, detection with non-contrast CT (NCCT) and CT angiography (CTA) is challenging. This study evaluates the impact of CT perfusion (CTP) on diagnostic accuracy, speed, and confidence in DMVO detection among physicians with varying expertise in stroke imaging.
MATERIALS AND METHODS: A retrospective, multi-reader diagnostic accuracy study was conducted with paired-patient, paired-reader design. Imaging from 50 patients with DSA-confirmed solitary DMVO, who received endovascular treatment, and 50 patients without stroke, confirmed by follow-up MRI, was included. Five readers of varying training backgrounds evaluated CT images in three sessions: Session 1A included NCCT+CTA of 50 cases (with and without stroke). In Session 1B, readers re-evaluated this cohort with access to CTP. Session 2 involved the remaining 50 mixed cases evaluated with NCCT+CTA+CTP. Primary endpoints were sensitivity and specificity for DMVO detection; secondary endpoints included time to diagnosis and diagnostic confidence. Statistical analysis utilized Bayesian generalized linear mixed models.
RESULTS: Sensitivity (84% vs. 100%) and specificity (94% vs. 99%) for DMVO detection improved with CTP, logarithmic odds ratio (sensitivity) of 10 (95%-CI: 3-33). This effect was consistent across all experience levels. Time to diagnosis decreased from 94±24 seconds to 49±24 seconds with CTP, and diagnostic confidence improved (median score increased from 4 to 5). Inter-reader agreement improved substantially, with Fleiss' kappa increasing from 0.62 (Session 1A) to 0.97 (Session 1B).
CONCLUSIONS: Incorporating CTP into imaging protocols significantly enhances diagnostic accuracy, speeds diagnosis, and improves diagnostic confidence for detecting DMVO across varying expertise.
引用
- Nguyen A, Schulze-Zachau V, Sinnecker T, et al. CT Perfusion improves Detection and Exclusion of Clinically Relevant Medium or Distal Vessel Occlusions - A Multi-Reader Diagnostic Accuracy Study. AJNR Am J Neuroradiol. 2026. PMID: 42551957. doi:10.3174/ajnr.A9564
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。