文献速递神经MR

列线图联合视觉影像与影像组学鉴别H3 G34突变型弥漫性半球胶质瘤与成人型弥漫性高级别胶质瘤

Nomogram combining visual imaging and radiomics analysis for distinguishing diffuse hemispheric glioma, H3 G34-mutant from adult-type diffuse high-grade gliomas.
PubMed 文献 · Neuroradiology · 2026-08-25

本研究回顾性纳入129例病理确诊的弥漫性高级别胶质瘤患者(H3 G34突变型DHG 50例,成人型弥漫性高级别胶质瘤79例),基于术前MRI提取VASARI视觉影像特征和全肿瘤影像组学特征,构建联合模型并绘制列线图。列线图在训练集和测试集的AUC分别为0.976和0.929,校准曲线和决策曲线分析显示良好的校准度和临床实用性。

要点

  • 年龄和扩散受限是H3 G34突变型DHG的独立预测因素。
  • 联合视觉影像与影像组学的列线图鉴别性能优于单一模型。
  • 列线图在训练集AUC 0.976、测试集AUC 0.929,校准和临床效用良好。

关键影像表现/征象

  • H3 G34突变型DHG可能具有独特的影像学特征。
  • 年龄和扩散受限是H3 G34突变型DHG的独立预测因素。

诊断标准与关键数值

  • 列线图在训练集的AUC为0.976,在测试集的AUC为0.929。
  • 列线图表现出良好的敏感度和特异度(原文未报告具体数值)。

临床应用与阅片要点

  • 术前MRI可结合年龄和扩散受限特征提示H3 G34突变型DHG的可能。
  • 列线图可作为术前无创鉴别H3 G34突变型DHG与成人型弥漫性高级别胶质瘤的辅助工具。

局限性

  • 回顾性研究设计。
  • 单中心样本,样本量有限(共129例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aims to develop an MRI-based predictive model to distinguish diffuse hemispheric glioma, H3 G34-mutant (H3 G34-mutant DHG) from adult-type diffuse high-grade gliomas.

METHOD: Preoperative MRI images were retrospectively collected from 129 patients with pathologically confirmed diffuse high-grade gliomas, including 50 patients with H3 G34-mutant DHG and 79 patients with adult-type diffuse high-grade gliomas. Visual imaging features were extracted in accordance with the Visually Accessible Rembrandt Images (VASARI) scoring system. Subsequently, the Least Absolute Shrinkage and Selection Operator (LASSO) regression was performed to remove redundant and highly collinear features. Univariable and multivariable logistic regression analyses were conducted to screen significant variables for model construction. Radiomic features were extracted from the whole tumor on multi-sequence MRI scans and selected via Mann-Whitney U test, Spearman correlation, Minimum redundancy maximum relevance (MRMR) algorithm, and LASSO regression. A radiomic predictive model was then constructed using the support vector machine (SVM) algorithm. Significant variables derived from clinical-visual imaging features and radiomic features were integrated into a combined predictive model, and a visualized nomogram was developed. Model discrimination performance was evaluated using the area under the curve (AUC), and clinical utility was assessed through decision curve analysis (DCA).

RESULTS: Age and diffusion restriction were independent predictors of H3 G34-mutant DHG. The nomogram exhibited superior overall performance compared with the clinical-visual imaging model and radiomics model. It yielded optimal AUC values of 0.976 in the training set and 0.929 in test set, along with favorable sensitivity and specificity. Calibration curves and DCA revealed satisfactory calibration and promising clinical utility for this nomogram.

CONCLUSION: H3 G34-mutant DHG may display distinct imaging characteristics. A nomogram integrating clinical-visual imaging and radiomic features may facilitate preoperative discrimination between H3 G34-mutant DHG and adult-type diffuse high-grade gliomas.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Pang B, Yuan M, Wang X, et al. Nomogram combining visual imaging and radiomics analysis for distinguishing diffuse hemispheric glioma, H3 G34-mutant from adult-type diffuse high-grade gliomas. Neuroradiology. 2026. PMID: 42640466. doi:10.1007/s00234-026-04158-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。