文献速递腹部CTMR

光子计数CT 190-keV单能成像替代真非增强CT评估肝脂肪变性

Single-Phase Surrogate for True Non-Contrast Liver CT Using 190-keV Monoenergetic Imaging on Photon-Counting CT: Implications for Hepatic Steatosis Assessment.
PubMed 文献 · Acad Radiol · 2026-07-21

回顾性分析49例接受腹部光子计数CT和MRI-PDFF检查的患者,比较190-keV虚拟单能图像与虚拟非增强图像对真非增强CT的替代价值。190-keV VMI与真非增强CT全肝衰减强相关(r=0.921),在前段区域偏差小于VNC,对脂肪变性诊断的AUC与TNC无显著差异。

要点

  • 190-keV VMI可作为真非增强CT的替代用于肝脂肪变性定量。
  • 前段区域VNC较TNC正偏差+5.5 HU,190-keV VMI偏差仅+2.2 HU。
  • 前段脂肪变性诊断AUC:VNC 0.817显著低于TNC 0.921,VMI 0.869与TNC无显著差异。

核心结论

  • 190-keV VMI可作为真非增强CT的实用替代用于肝脂肪变性定量。
  • 与VNC相比,190-keV VMI在易产生伪影的区域表现出更小的节段依赖性偏差。

研究设计与样本

  • 回顾性研究,纳入49例(男30例、女19例,平均年龄66.7±11.2岁)在2个月内接受腹部PCD-CT和MRI-PDFF检查的患者。
  • VNC和190-keV VMI由平衡期扫描重建,在四个肝段测量肝衰减,以TNC为参考标准。
  • 采用Pearson相关和Bland-Altman分析评估与TNC的一致性,ROC分析评估对脂肪变性(MRI-PDFF≥5%)的诊断效能。

关键影像表现/征象

  • 全肝分析中190-keV VMI与TNC强相关(r=0.921,p<0.001),与VNC(r=0.925)相当。
  • 前段区域VNC相对TNC呈较大正偏差(+5.5 HU),190-keV VMI偏差较小(+2.2 HU),更准确再现区域衰减模式。

诊断标准与关键数值

  • 脂肪变性定义:MRI-PDFF≥5%。
  • 前段脂肪变性诊断AUC:TNC 0.921 vs VNC 0.817(p=0.018),TNC vs 190-keV VMI 0.869(p=0.149)。

临床应用与阅片要点

  • 在无法获得真非增强扫描时,可考虑用190-keV VMI替代TNC进行肝衰减测量和脂肪变性评估。
  • VNC在前段等易产生伪影区域存在较大正偏差,可能导致脂肪变性评估偏差,190-keV VMI可减轻该偏差。

局限性

  • 回顾性研究,样本量49例,单中心设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate whether 190-keV virtual monoenergetic imaging (VMI) using photon-counting detector CT (PCD-CT) can serve as a surrogate for true non-contrast (TNC) in hepatic steatosis quantification and to compare its attenuation agreement with virtual non-contrast (VNC).

METHODS: Forty-nine patients who underwent abdominal PCD-CT and MRI-proton density fat fraction (PDFF) within 2 months were retrospectively analyzed. VNC and 190-keV VMI were reconstructed from equilibrium-phase scans. Liver attenuation was measured on TNC, VNC, and 190-keV VMI in four hepatic segments. Pearson correlation and Bland-Altman analyses assessed agreement with TNC. Receiver operating characteristic analysis evaluated diagnostic performance for steatosis (MRI-PDFF ≥ 5%). Statistical analyses were performed using MedCalc (version 23.4) and GraphPad Prism (version 10.6.1). Statistical significance was defined as p < 0.05.

RESULTS: The study included 49 patients (30 men, 19 women; mean age, 66.7 ± 11.2 years). In whole-liver analysis, 190-keV VMI correlated strongly with TNC (r=0.921, p<0.001), comparable to VNC (r=0.925). In the anterior segment, VNC showed a larger positive bias relative to TNC (+5.5 HU), whereas 190-keV VMI showed a smaller bias (+2.2 HU) that more accurately reproduced the regional attenuation pattern. For detecting steatosis in the anterior segment, a significant difference in area under the curve was observed between TNC and VNC (0.921 vs 0.817, p=0.018), whereas no significant difference was found between TNC and 190-keV VMI (0.921 vs 0.869, p=0.149).

CONCLUSION: 190-keV VMI may serve as a practical surrogate for TNC in hepatic steatosis quantification, demonstrating reduced segment-dependent bias compared with VNC in artifact-prone regions.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ohtani T, Shimada M, Nishiyama K, et al. Single-Phase Surrogate for True Non-Contrast Liver CT Using 190-keV Monoenergetic Imaging on Photon-Counting CT: Implications for Hepatic Steatosis Assessment. Acad Radiol. 2026. PMID: 42476835. doi:10.1016/j.acra.2026.06.064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。