双能CT评估肝癌TACE术后疗效:与常规CT的回顾性对比研究
本研究以MRI为标准,回顾性比较双能CT的40-keV单能图像与常规CT对48例患者76个肝癌病灶TACE术后存活残留的评估价值。MonoE40在诊断效能、病灶清晰度、动脉期CNR及观察者间一致性上均优于CCT,尤其对小于2 cm的存活成分和低年资阅片者获益更明显。
要点
- TACE术后评估存活残留优先重建40-keV单能图像,可提高小病灶检出率。
- MonoE40对存活成分<2 cm的检出率明显高于常规CT。
- MonoE40提高病灶边界勾勒一致性及低年资医师判读一致性。
核心结论
- 40-keV单能重建的双能CT较常规CT显著提高TACE术后存活残留肝癌的检出、边界勾勒和观察者间一致性。
研究设计与样本
- 单中心回顾性研究,纳入48例患者76个肝癌病灶,均在常规TACE后3个月内完成双能CT与MRI检查。
- 从双能CT数据重建常规CT图像和40-keV单能图像,由对MRI结果设盲的放射科医师独立诊断。
- 以MRI为参考标准,分析SNR、CNR、Dice相似系数及Fleiss kappa一致性。
关键影像表现/征象
- MonoE40较CCT显示更高的诊断信心、病灶清晰度和动脉期CNR(P < 0.001)。
- 肿瘤勾画的Dice系数从CCT的0.31至0.54提高至MonoE40的0.76至0.95(P < 0.05)。
诊断标准与关键数值
- MRI证实的存活病灶共55个。
- MonoE40诊断效能显著优于CCT(P < 0.05)。
- 对存活成分<2 cm的病灶,MonoE40检出率为74.1%至85.2%,CCT为25.9%至48.1%。
- 全病灶水平观察者间一致性MonoE40的κ = 0.55,CCT为κ = 0.29。
- 低年资阅片者一致性从κ = 0.35提高至κ = 0.59。
临床应用与阅片要点
- TACE术后随访建议在双能CT上常规重建40-keV单能图像以辅助判断存活残留。
- 对<2 cm的存活成分应重点结合MonoE40图像,避免常规CT低估残留。
- MonoE40有助于统一不同年资医师对肿瘤边界的判读,便于报告描述。
局限性
- 单中心回顾性设计,样本量有限(48例76个病灶),结论外推需多中心验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND & AIMS: Conventional CT (CCT) is widely used to assess hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE), but its diagnostic performance is often limited by lipiodol-induced beam-hardening artifacts and poor contrast resolution. Dual-energy CT (DECT) with low-keV monochromatic imaging may improve detection of viable residual tumors, yet its clinical value remains to be fully established. This study compared diagnostic performance, image quality, spatial accuracy, and interobserver agreement of DECT versus CCT for identifying viable HCC post-TACE using MRI as the reference standard.
MATERIALS AND METHODS: This retrospective, single-center study included 48 patients with 76 HCC lesions who underwent both DECT and MRI within 3 months after conventional TACE. Conventional CT (CCT) and 40-keV monoenergetic (MonoE40) images were reconstructed from DECT data. Diagnoses were independently assessed by radiologists blinded to MRI results. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), Dice similarity coefficient (DSC) for spatial agreement, and Fleiss' kappa for interobserver agreement were analyzed.
RESULTS: Fifty-five lesions were viable per MRI. MonoE40 images showed significantly superior diagnostic performance compared to CCT (P < 0.05), especially for lesions with viable components < 2 cm (detection rates: 74.1 %-85.2 % vs. 25.9 %-48.1 %). MonoE40 also yielded higher diagnostic confidence, lesion conspicuity, and arterialphase CNR (P < 0.001). Dice coefficients for tumor delineation improved from 0.31 to 0.54 on CCT to 0.76-0.95 on MonoE40 (P < 0.05). Interobserver agreement at whole-lesion level was higher with MonoE40 (κ = 0.55) versus CCT (κ = 0.29), with the greatest improvement among less-experienced readers (κ from 0.35 to 0.59).
CONCLUSION: DECT with 40-keV monochromatic reconstruction significantly improves detection of viable residual HCC after TACE, enhances tumor boundary delineation, and increases consistency among radiologists compared with CCT, especially benefiting less-experienced readers. These results support incorporating DECT into standard post-TACE imaging protocols.
引用
- Sun Z, Zhang S, Zhou S, et al. Value of dual-energy CT in assessing therapeutic response after TACE for hepatocellular carcinoma: A retrospective comparative study with conventional CT. Eur J Radiol. 2026. PMID: 42287903. doi:10.1016/j.ejrad.2026.113002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。