基于MR生成合成CT用于无辐射髋关节形态计算机辅助量化
该回顾性研究纳入70例同时接受CT和MR扫描的患者,比较基于高分辨率和模拟低分辨率MR生成的合成CT与常规CT在髋关节形态量化中的表现。结果显示骨盆分割精度高,多数髋形态参数一致性优秀,支持无辐射量化髋形态的可行性。
要点
- 合成CT骨盆分割精度高,高分辨率与低分辨率MR生成图像均表现良好。
- 多数髋形态参数与真实CT一致性优秀(ICC≥0.90),低分辨率MR的LCE角一致性良好(ICC≥0.75)。
- 合成CT与真实CT间无临床相关差异,支持无辐射髋形态评估。
局限性
- 回顾性研究设计
- 样本量有限(70例,测试集35例)
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare MR image-based synthetic CT (sCT) with conventional CT for computer-assisted quantification of hip morphology by evaluating osseous structure segmentation quality and hip morphological parameters.
MATERIALS AND METHODS: This retrospective study included patients undergoing both CT and MR scans. The sCT images generated from both high-resolution (HR) and simulated low-resolution (LR) MR images were evaluated. Segmentation accuracy was assessed using Dice similarity coefficient (DSC) and average symmetric surface distance (ASSD). Two readers independently measured seven typical hip morphological parameters for computer-assisted diagnosis of developmental hip dysplasia: anteversion, inclination, lateral center-edge (LCE) angle, extrusion index, and three femoral head coverage measurements (total, anterior, and posterior). Inter-modality, inter-reader, and intra-reader agreements were assessed using intraclass correlation coefficient (ICC) and mean absolute difference.
RESULTS: The study included 70 patients, with 35 for model development and remaining 35 for testing. Compared with real CT, segmentation of the pelvis demonstrated high accuracy for both HR MR image-based sCT (DSC = 93.8 ± 1.7%, ASSD = 0.80 ± 0.36 mm) and LR MR image-based sCT (DSC = 93.6 ± 1.8%, ASSD = 0.82 ± 0.37 mm). Inter-modality agreement for most hip morphological parameters was excellent (ICC ≥ 0.90), while LCE angle for LR MR image-based sCT showed good agreement (ICC ≥ 0.75). Inter-reader and intra-reader agreements were excellent (ICC ≥ 0.90). No clinically relevant differences were observed between real CT and sCT for any morphological parameter.
CONCLUSION: The MR image-based sCT provides accurate osseous structure segmentation and clinically acceptable hip morphological parameters, supporting the feasibility of radiation-free quantification of hip morphology.
引用
- Ye K, Sun W, Zheng G, et al. Generating synthetic CT from MR images for radiation-free computer-assisted quantification of hip morphology. Eur J Radiol. 2026. PMID: 42176556. doi:10.1016/j.ejrad.2026.112962
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。