超声影像组学联合瘤内Habitat与瘤周区域预测钙化乳腺病灶恶性风险
该单中心回顾性研究纳入510个乳腺钙化病灶,基于超声图像提取瘤内Habitat及瘤周3/5/7像素区域的影像组学特征构建机器学习模型。外部测试集显示5像素_XGBoost模型AUC为0.763,显著优于仅病灶模型(AUC=0.623),且与经验丰富的超声医师诊断效能相当。
要点
- 瘤周区域影像组学特征可提升钙化乳腺病灶的恶性预测效能。
- 5像素_XGBoost模型在外部测试集AUC为0.763,优于仅病灶模型。
- 该模型诊断效能与有经验超声医师相当,可作为辅助决策工具。
关键影像表现/征象
- 瘤内聚类识别出4个Habitat,据此构建8个区域特异性影像组学模型。
- 内部测试集中多数模型表现良好,仅Habitat2_LR模型AUC为0.819且与仅病灶模型差异有统计学意义(p<0.05)。
- 外部测试集中3像素_LR模型AUC为0.780(p=0.022)、5像素_XGBoost模型AUC为0.763(p=0.049),均显著优于仅病灶模型(AUC=0.623)。
- 校准曲线、决策曲线分析及读者比较支持5像素_XGBoost模型的稳健性和净获益,其AUC与有经验超声医师相当(所有p>0.05)。
诊断标准与关键数值
- 5像素_XGBoost模型外部测试集AUC=0.763,与仅病灶模型AUC=0.623相比差异有统计学意义(p=0.049)。
- 3像素_LR模型外部测试集AUC=0.780,与仅病灶模型相比差异有统计学意义(p=0.022)。
- Habitat2_LR模型内部测试集AUC=0.819,与仅病灶模型相比差异有统计学意义(p<0.05)。
- 5像素_XGBoost模型AUC与有经验超声医师相比差异均无统计学意义(所有p>0.05)。
临床应用与阅片要点
- 阅片时可关注钙化病灶瘤周3–5像素区域,该区域影像组学特征有助于恶性风险分层。
- 5像素_XGBoost模型可作为超声医师的辅助诊断工具,尤其用于钙化病灶的良性/恶性鉴别。
- 模型输出需结合医师经验综合判断,避免单一依赖影像组学评分。
局限性
- 研究为单中心回顾性设计,内部测试集结果可能受选择偏倚影响。
- 外部测试集仅84例且来自公共数据集,样本量有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To evaluate whether intratumoral habitats and peritumoral regions on ultrasound (US) images enhance radiomics-based diagnosis of calcified breast lesions.
MATERIALS AND METHODS: Mammography-confirmed calcified breast lesions were retrospectively collected from a single center and divided into training and internal test sets. An external test set of 84 cases was obtained from two public datasets. Pathology was the reference for biopsied lesions, while benignity in non-biopsied cases required ≥24-month follow-up. Intratumoral clustering defined optimal habitat numbers. Lesion ROIs were expanded by 3, 5, and 7 pixels to capture peritumoral regions. Machine-learning models were developed and evaluated internally and externally using Receiver Operating Characteristic (ROC) analysis, and compared with four experienced sonographers.
RESULTS: A total of 510 lesions from 492 female were enrolled. Four intratumoral clusters were identified, resulting in eight region-specific radiomics models. In the internal test set, most models performed well except Habitat2_LR (Area under the Receiver Operating Characteristic Curve [AUC] = 0.819, p < 0.05 vs the lesion-only model). In the external test set, 3-pixel_LR (AUC = 0.780, p = 0.022) and 5-pixel_XGBoost (AUC = 0.763, p = 0.049) significantly outperformed the lesion-only model (AUC = 0.623). Calibration, decision-curve analysis, and reader comparisons supported the robustness and net benefit of the 5-pixel_XGBoost model, whose AUC was comparable to that of experienced sonographers (all p > 0.05).
CONCLUSION: Incorporating peritumoral regions improves US-based radiomics diagnosis of calcified breast lesions, with the 5-pixel_XGBoost model providing the best overall performance.
引用
- Wang X, Zhang N, Ma J, et al. Malignancy Prediction of Breast Lesion with Calcifications via Radiomics Analysis Based on Intratumoral and Peritumoral Regions of Ultrasound Images. Acad Radiol. 2026. PMID: 42156305. doi:10.1016/j.acra.2026.04.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。