本文综述乳腺MRI伪影的成因、表现及应对策略,将伪影分为技术相关与患者相关两类,涵盖图像采集、重建、组织特性及运动、摆位、体型等因素,强调识别伪影来源并采取纠正措施对提高乳腺MRI评估可靠性的重要性。

要点

  • 伪影可降低图像质量与诊断信心,识别其来源是正确解读的前提。
  • 技术伪影涉及对比剂时机、视野、射频干扰、配准错误、Gibbs伪影、化学位移及磁敏感伪影。
  • 患者相关伪影常源于运动、摆位不佳及体型差异,需通过标准化流程与正确摆位减少。

核心结论

  • 识别乳腺MRI伪影、理解其起源并应用纠正策略,对提高乳腺MRI评估的可靠性至关重要。

研究设计与样本

  • 本文为综述,检索范围与纳入文献未在摘要中报告。

关键影像表现/征象

  • 技术伪影可表现为图像采集相关(对比剂时机不当、视野受限、射频干扰)、重建相关(配准错误、Gibbs振铃)或组织特性相关(化学位移、磁敏感)的失真。
  • 患者相关伪影常由运动、摆位欠佳或体型差异引起。

临床应用与阅片要点

  • 日常阅片需区分技术伪影与患者相关伪影,避免将伪影误判为病变或影响分期。
  • 维持高质量成像需遵循标准化协议、设备正确校准及患者正确摆位。
  • 合理选择序列并正确给予对比剂可提高图像一致性与诊断性能。

局限性

  • 本文为综述,未报告原始研究的样本量、中心数及具体诊断效能数值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

MRI of the breast has a key role in early detection of breast cancer and evaluation of the extent of disease. The most common indications for breast MRI include screening in women at high risk for breast cancer and staging of newly diagnosed breast cancer. Additional indications include assessment of response to neoadjuvant therapy, problem solving in equivocal cases, evaluation of carcinoma with an unknown primary tumor, and assessment of implant integrity. Image interpretation can be limited by artifacts-image distortions resulting from technical factors or patient-related issues that degrade image quality and reduce diagnostic confidence. Identifying artifacts, understanding their origins, and applying corrective strategies are critical to improving the reliability of breast MRI assessment. Artifacts can be broadly categorized as technical or patient related. Technical artifacts include those related to image acquisition (eg, inadequate contrast material timing, limited field of view, or radiofrequency interference), reconstruction (eg, misregistration or Gibbs ringing), or tissue characteristics (eg, chemical shift or magnetic susceptibility). Patient-related artifacts often arise from motion, suboptimal positioning, or variations in body habitus. Maintaining high-quality imaging requires adherence to standardized protocols, proper calibration of equipment, and appropriate positioning of the patient. Thoughtful selection of sequences and correct administration of contrast material further enhance image consistency and diagnostic performance. ©RSNA, 2026 Supplemental material is available for this article.

来源:Radiographics,查看原文。版权归原作者所有。

引用

  1. Quispe Villca F, Pesce KA, Choque Leniz G, et al. Artifacts at Breast MRI: Appearances and Solutions. Radiographics. 2026. PMID: 42126967. doi:10.1148/rg.250088

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。