全身麻醉联合升压药支持对胎儿脊髓脊膜膨出修复术中子宫胎盘灌注的影响
这项前瞻性单中心研究纳入33例孕中期行胎儿脊髓脊膜膨出修复术的孕妇,评估全身麻醉联合升压药支持对子宫血流动力学的影响。结果显示麻醉后5分钟子宫动脉搏动指数和血流量与术前基线相当,但手术结束时子宫动脉阻力升高、血流量下降,且持续至术后第6天未恢复;胎儿脐动脉多普勒改变在术后即刻恢复。
要点
- 全麻联合升压药支持可短期维持子宫灌注,但手术操作本身导致子宫动脉阻力升高、血流量下降,术后6天未恢复。
- 术中及术后需关注子宫动脉多普勒变化,胎儿脐动脉指标术后即刻恢复,提示胎儿循环影响短暂。
- 开放与腔镜修复两种术式对子宫动脉及胎儿多普勒参数无显著差异。
关键影像表现/征象
- 术前子宫动脉搏动指数中位数0.77(IQR 0.64-0.95),阻力指数中位数0.52(IQR 0.45-0.59),血流量中位数307.5(IQR 209.8-542.2)mL/min。
- 麻醉后5分钟子宫动脉搏动指数中位数0.87(IQR 0.68-1.04),血流量中位数310.7(IQR 199.0-421.4)mL/min,与基线相比均无显著差异(P>0.05)。
- 麻醉后5分钟脐动脉搏动指数高于基线(P=0.008),同时胎心率下降。
- 手术结束时子宫动脉搏动指数中位数1.46(IQR 1.04-2.21)、阻力指数中位数0.76(IQR 0.62-0.91)均较基线升高(均P<0.001),血流量中位数182.1(IQR 79.8-351.5)mL/min较基线降低(P=0.031)。
- 子宫动脉搏动指数和阻力指数升高持续至术后第1天和第6天,而脐动脉指标基本恢复至术前基线水平;开放与腔镜修复两种术式间子宫动脉及胎儿多普勒参数无显著差异。
局限性
- 单中心研究,样本量33例,开放与腔镜修复例数不均衡(23例 vs 10例)。
- 研究未设未手术对照组,无法区分麻醉与手术操作对子宫血流的独立影响。
- 术后随访仅至第6天,未评估更长期的血流恢复情况。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the combined effect of maternal general anesthesia and vasopressor support on uterine hemodynamics during the second trimester in pregnancies undergoing fetal spina bifida repair and to determine whether fetal spina bifida repair alters uteroplacental perfusion.
METHODS: This was a prospective single-center study conducted at the Fetal Medicine Unit of University Hospitals Leuven, Leuven, Belgium between August 2021 and April 2025. All participants underwent fetal spina bifida repair under general anesthesia with vasopressor support, titrated to maintain a mean arterial pressure ≥ 90% of the preoperative baseline value. Uterine artery (UtA) and umbilical artery Doppler measurements were obtained at six timepoints: (1) the day before surgery to establish preoperative baseline values; (2) immediately after epidural catheter placement, initiation of general anesthesia and intubation (at the initiation of noradrenaline); (3) 5 min after initiation of general anesthesia with vasopressor support; (4) at the end of surgery, after maternal skin closure and before extubation; (5) on postoperative day 1; and (6) on postoperative day 6. The primary outcome was the change in UtA pulsatility index (PI) 5 min after initiation of general anesthesia compared with the preoperative baseline value. Secondary outcomes included UtA blood flow estimated from time-averaged maximum velocity and vessel diameter and fetal umbilical artery Doppler parameters. Statistical analysis included paired t-tests, Wilcoxon signed-rank tests and mixed-effects models.
RESULTS: A total of 33 women undergoing fetal spina bifida repair were included, of whom 23 underwent open repair and 10 underwent fetoscopic repair. At the preoperative baseline, median UtA-PI was 0.77 (interquartile range (IQR), 0.64-0.95), median UtA resistance index (RI) was 0.52 (IQR, 0.45-0.59) and median UtA blood flow was 307.5 (IQR, 209.8-542.2) mL/min. At 5 min after the initiation of general anesthesia with vasopressor support, UtA-PI (median, 0.87 (IQR, 0.68-1.04)) and UtA blood flow (median, 310.7 (IQR, 199.0-421.4) mL/min) were comparable to baseline values (both P > 0.05). At this timepoint, umbilical artery PI was higher than the baseline value (P = 0.008) while fetal heart rate decreased. At the end of surgery, UtA-PI (median, 1.46 (IQR, 1.04-2.21)) and UtA-RI (median, 0.76 (IQR, 0.62-0.91)) were elevated compared with baseline values (both P < 0.001) and UtA blood flow was reduced (median, 182.1 (IQR, 79.8-351.5) mL/min; P = 0.031). Elevation of UtA-PI and UtA-RI persisted on postoperative days 1 and 6, but umbilical artery indices generally normalized back to preoperative baseline levels. There were no significant differences in UtA or fetal Doppler parameters between surgical techniques.
CONCLUSIONS: General anesthesia with vasopressor support preserved uterine perfusion and blood flow without increasing vascular resistance. During fetal spina bifida repair, UtA resistance increased and UtA blood flow decreased. These parameters did not normalize back to preoperative baseline values within 6 days after surgery. In contrast, perioperative fetal Doppler changes resolved immediately postoperatively © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Vergote S, Van der Veeken L, Van den Eede E, et al. Impact of general anesthesia with vasopressor support on uteroplacental perfusion during fetal spina bifida repair. Ultrasound Obstet Gynecol. 2026. PMID: 42113685. doi:10.1002/uog.70237
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。