文献速递腹部技术与安全MR

基于可解释MRI多参数影像组学术前预测结直肠癌CMS4亚型

Interpretable MRI-based Multiparametric Radiomics for Preoperative Prediction of CMS4 Colorectal Cancer.
PubMed 文献 · Radiology · 2026-01-01

这项多中心回顾性研究纳入253例结直肠癌患者,利用术前腹部/盆腔/直肠MRI(T2WI和增强T1WI)提取影像组学特征构建机器学习模型MRC4s,预测CMS4亚型。合并序列MRC4s在内外部测试集AUC分别为0.85和0.84,优于深度学习模型,并与复发转移风险及TGF-β、上皮间质转化通路相关。

要点

  • 联合增强T1WI与T2WI的MRC4s可无创预测CMS4,内外部AUC达0.85和0.84。
  • MRC4s高风险分层与复发转移风险升高相关(HR 5.96,P < .001)。
  • MRC4s优于ResNet50、VGG16、DenseNet201等深度学习模型(AUC 0.70–0.75)。

关键影像表现/征象

  • 模型基于T2WI和增强T1WI提取的影像组学特征构建,合并序列模型表现最佳。
  • 转录组分析显示合并MRC4s与TGF-β及上皮间质转化通路相关。

诊断标准与关键数值

  • 合并MRC4s预测CMS4的内部测试集AUC为0.85(95% CI: 0.63, 1.00)。
  • 合并MRC4s预测CMS4的外部测试集AUC为0.84(95% CI: 0.73, 0.95)。
  • 深度学习对照模型AUC范围为0.70–0.75,均低于MRC4s(P < .01)。
  • MRC4s风险分层与复发转移的HR为5.96(P < .001)。

临床应用与阅片要点

  • 术前MRI可无创评估CMS4状态,辅助风险分层,减少对免疫组化分型的依赖。
  • 建模需联合增强T1WI与T2WI特征,单一序列可能低估性能。
  • 判读时需结合临床分期和随访,模型输出不能替代病理分型。

局限性

  • 回顾性设计,样本量有限(253例),外部队列规模未报告。
  • CMS分型以免疫组化为参考标准,不同中心抗体和判读可能存在差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Consensus molecular subtypes (CMSs) are associated with prognostic and clinical outcomes in colorectal cancer (CRC); however, effective noninvasive methods for CMS4 identification are limited. Purpose To evaluate whether a radiomics-based machine learning approach can predict CMS4 status in CRC and to explore its biologic relevance and interpretability of radiomics features. Materials and Methods This multicenter, retrospective study included patients with CRC who underwent abdominal, pelvic, or rectal MRI (January 2015 to April 2020). Patients were followed until recurrence or metastasis or up to 60 months, whichever occurred first. A subgroup of patients was randomly divided into a training and an internal test set, whereas another subgroup constituted the external test set. Pathologic tissue and MRI data were collected, including T2-weighted imaging (T2WI) and contrast-enhanced (CE) T1-weighted imaging (T1WI). CMS classification was determined using immunohistochemistry. A machine learning model was developed to generate an MRI radiomics CMS4 score (MRC4s) for predicting CMS4 status. Deep learning models (ResNet50, VGG16, and DenseNet201) were also implemented as comparators. Performance was evaluated using receiver operating characteristic curve analysis. Bulk and single-cell RNA sequencing data from patients with CRC was used to investigate the association between MRC4s and biologic pathways. Results This study included 253 patients (median age, 63 years; IQR, 55-69 years; 163 men). The merged MRC4s, combining CE T1WI and T2WI features, achieved areas under the receiver operating characteristic curve (AUCs) of 0.85 (95% CI: 0.63, 1.00) in the internal and 0.84 (95% CI: 0.73, 0.95) in the external test sets, outperforming state-of-the-art deep learning models (AUC range, 0.70-0.75; all P < .01). Merged MRC4s stratified the risk of recurrent metastasis (hazard ratio, 5.96; P < .001). Transcriptomic analyses revealed the merged MRC4s were associated with transforming growth factor-β and epithelial-mesenchymal transition pathways. Conclusion A machine learning radiomics model based on preoperative multiparametric MRI predicted CMS4 of CRC from other subtypes with strong performance and biologic interpretability supported by transcriptomic analyses. © The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Arita and Kim in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Liu Z, Gu W, Liu L, et al. Interpretable MRI-based Multiparametric Radiomics for Preoperative Prediction of CMS4 Colorectal Cancer. Radiology. 2026. PMID: 42153825. doi:10.1148/radiol.251719

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。