时间分辨MR血管成像左房达峰时间作为房颤消融术前左房压无创指标
回顾性纳入92例房颤消融术前患者,用时间分辨MR血管成像测量左房达峰时间(TTP),以导管测压为参考标准(高左房压≥15 mmHg)。高左房压组TTP显著延长(25.1±6.9 s vs. 16.9±5.7 s,P<0.001),TTP独立关联左房压(β=0.46,P<0.001),识别高左房压的AUC为0.834(95%CI 0.742-0.904)。
要点
- TTP>19.6 s识别高左房压的敏感度81.8%、特异度75.7%。
- 高左房压者TTP明显延长,提示左房充盈/排空延迟。
- TTP可作为房颤消融术前无创评估左房压的影像标志。
核心结论
- TR-MRA衍生的左房TTP与有创测量的左房压独立相关,可作为识别房颤消融术前高左房压的可靠无创影像标志。
研究设计与样本
- 采用对比增强时间-信号强度曲线测量左房TTP,以窦性心律下导管测压为参考标准,高左房压定义为≥15 mmHg。
- 采用单变量和多变量线性回归分析(左房压为因变量、超声参数为协变量),并以ROC曲线评估TTP诊断效能。
关键影像表现/征象
- 高左房压组左房TTP显著长于低左房压组(25.1±6.9 s vs. 16.9±5.7 s,P<0.001)。
诊断标准与关键数值
- TTP识别高左房压(≥15 mmHg)的AUC为0.834(95%CI 0.742-0.904)。
- 以TTP>19.6 s为截断值,识别左房压升高的敏感度为81.8%(18/22),特异度为75.7%(53/70)。
临床应用与阅片要点
- 对拟行房颤消融术的患者,可测量TR-MRA左房TTP作为无创左房压评估指标。
- TTP>19.6 s提示高左房压可能,报告时可提示临床关注左房压升高。
局限性
- 本研究为回顾性单中心设计,样本量92例,结论需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the performance of the left atrial time-to-peak (TTP) derived from time-resolved magnetic resonance angiography (TR-MRA) as a noninvasive indicator of left atrial pressure (LAP) in patients with atrial fibrillation (AF).
MATERIALS AND METHODS: This retrospective study included 92 patients who underwent cardiac TR-MRA and catheter-based LAP measurements prior to catheter ablation for AF between January 2021 and December 2022. TR-MRA-derived TTP was measured in the left atrium using contrast-enhanced time-signal intensity curves. Catheter-based LAP measured during sinus rhythm served as the reference standard, with high LAP defined as ≥15 mmHg. Univariable and multivariable linear regression analyses were performed, with LAP as the dependent variable and echocardiographic parameters as covariates. The diagnostic performance of TTP for high LAP was evaluated using receiver operating characteristic (ROC) curve analysis.
RESULTS: Among the 92 patients (mean age ± standard deviation, 60 ± 10 years; 70 male), 70 (76.0%) had low LAP, and 22 (23.9%) had high LAP. Mean TTP was significantly longer in patients with high LAP than in those with low LAP (25.1 ± 6.9 s vs. 16.9 ± 5.7 s, P < 0.001). In multivariable linear regression analysis, TTP remained independently associated with LAP (β = 0.46, P < 0.001). ROC analysis demonstrated good discriminative performance of TTP for identifying high LAP, with an area under the curve of 0.834 (95% confidence interval, 0.742-0.904). Using a TTP cutoff of >19.6 seconds, the sensitivity and specificity for identifying elevated LAP levels were 81.8% (18/22) and 75.7% (53/70), respectively.
CONCLUSION: TR-MRA-derived TTP showed a significant independent association with invasively measured LAP. It may serve as a reliable noninvasive imaging marker for identifying high LAP in patients with AF undergoing catheter ablation.
引用
- Shim J, Park S, Oh YW, et al. Left Atrial Time-to-Peak From Time-Resolved MR Angiography as a Noninvasive Indicator of Left Atrial Pressure Before Catheter Ablation of Atrial Fibrillation. Korean J Radiol. 2026. PMID: 42062226. doi:10.3348/kjr.2025.1622