TAVR术前CTA评估中内部与第三方供应商测量值的可靠性比较
心脏CTA的13项指标中10项一致性优良(ICC 0.91-0.98),髂股动脉的12项指标中10项一致性中等至良好(ICC 0.70-0.85)。结论认为内部CTA测量在TAVR规划中可靠性高,尤其心脏参数,血管入路测量差异无临床意义且未改变患者管理。
要点
- 心脏CTA测量在明确解剖标志处一致性高(ICC 0.91-0.98),可优先用于TAVR规划。
- 髂股动脉测量因血管解剖复杂、钙化及操作者选点差异一致性较低(ICC 0.70-0.85)。
- 内部数据处理可作为外部分析的安全有效替代,有助于提升工作流程效率。
局限性
- 单中心回顾性设计,样本量56例,可能存在选择偏倚。
- 未报告外部供应商的具体测量方法及操作者间变异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: Computed tomography angiography (CTA) is essential for preprocedural assessment in transcatheter aortic valve replacement (TAVR), particularly as TAVR becomes the preferred treatment for high-risk patients with severe aortic stenosis. This study compares CTA measurements generated internally with those from an external third-party vendor, focussing on consistency and reliability.
MATERIALS AND METHODS: We retrospectively analysed 56 patients who underwent standardised pre-TAVR cardiac CTA and CTA of the chest, abdomen, and pelvis. Twenty-five key parameters were measured including cardiac and iliofemoral arterial dimensions. Agreement between internal and external data was assessed using intraclass correlation coefficients (ICCs).
RESULTS: Among 13 cardiac CTA metrics, 10 metrics demonstrated excellent or good-to-excellent agreement (ICCs 0.91-0.98). Of the 12 iliofemoral metrics, 10 metrics demonstrated moderate-to-good agreement (ICCs 0.70-0.85).
CONCLUSION: Cardiac measurements, often obtained at well-defined anatomical landmarks, demonstrated stronger agreement than iliofemoral measurements, which are more prone to variability due to complex vascular anatomy, calcifications, and operator-dependent site selection. Internally generated CTA measurements for TAVR planning show high reliability, especially for cardiac parameters. Although vascular access measurements showed lower agreement, differences were not clinically significant and did not alter patient management. These findings support the use of internal data processing as a safe and effective alternative to external analysis, with potential benefits in workflow efficiency and patient care.
引用
- Claus L, Zhang X, Ocasio L, et al. Comparative reliability of internal and vendor-derived computed tomography angiography (CTA) measurements in pretranscatheter aortic valve replacement (TAVR) assessment. Clin Radiol. 2026. PMID: 42106213. doi:10.1016/j.crad.2026.107312
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。