冠状动脉周围脂肪与心外膜脂肪衰减比值在冠脉CTA中检测心肌血流储备受损
本研究回顾性纳入74例同时接受冠脉CTA和13N-氨水PET的患者,探讨将冠脉周围脂肪衰减(PCAT)归一化至心外膜脂肪衰减(EAT)能否减少CT采集参数影响并提高对心肌血流储备(MFR)受损的诊断效能。
要点
- PCAT/EAT比值较未校正PCAT更少受管电压和心电门控影响,诊断MFR受损效能更高。
- PCAT/EAT比值每降低0.05,MFR<2的比值比为1.82(95%CI 1.16-3.01)。
诊断标准与关键数值
- 以PET衍生MFR<2为MFR受损参考标准。
- PCAT/EAT比值每降低0.05,MFR<2的OR为1.82(95%CI 1.16-3.01)。
临床应用与阅片要点
- 在异质性CCTA协议下,建议采用PCAT/EAT比值替代未校正PCAT评估MFR受损,以减少管电压等采集参数影响。
局限性
- 回顾性研究,样本量较小(74例),PCAT/EAT比值<1与预后的关联为假设生成性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To investigate whether normalizing pericoronary adipose tissue (PCAT) attenuation to epicardial fat attenuation (EAT) reduces susceptibility to CT acquisition settings, particularly tube potential, and improves diagnostic performance for impaired myocardial flow reserve (MFR) and its prognostic value compared with PCAT attenuation in real-world heterogeneous coronary CT angiography (CCTA) protocols. Materials and Methods This retrospective study included patients who underwent CCTA and nitrogen 13 ammonia PET from September 2019 to December 2024. CCTA was performed on three CT systems with varying tube potentials (70-120 kV). PCAT attenuation was semiautomatically measured around the proximal right coronary artery, and EAT attenuation was automatically assessed. A PET-derived MFR of less than 2 was used as the reference standard for impaired MFR. Factors related to PCAT metrics, diagnostic odds ratios (ORs) for impaired MFR using multivariable logistic regression, and exploratory time-to-event analysis of major adverse cardiac events were evaluated. Results The analysis included 74 patients (median age, 72 years [IQR, 60-79 years]; 41 male). PCAT attenuation was affected by the tube potential (P < .001) and electrocardiography gating (P = .01). In contrast, the PCAT/EAT ratio was associated with impaired MFR (P = .01) and coronary stenosis (P = .009). It helped predict an MFR less than 2 (OR per 0.05-decrease, 1.82 [95% CI: 1.16, 3.01]) and showed higher diagnostic performance than did uncorrected PCAT (area under the receiver operating characteristic curve, 0.71 vs 0.56; P = .006). A PCAT/EAT ratio less than 1 showed a hypothesis-generating association with lower event-free survival in patients without severe stenosis (log-rank P = .045). Conclusion The PCAT/EAT ratio reduced scan-related variability and outperformed PCAT attenuation in diagnosing impaired MFR. Keywords: CT Angiography, Coronary Artery Disease, Epicardial Adipose Tissue, Inflammation, Atherosclerosis, Image Processing, Computer-Assisted Supplemental material is available for this article. © RSNA, 2026 See also commentary by Murphy in this issue.
引用
- Fukuyama M, Nishii T, Okura Y, et al. Pericoronary-to-Epicardial Fat Attenuation Ratio for Detecting Impaired Myocardial Flow Reserve at Coronary CT Angiography. Radiol Cardiothorac Imaging. 2026. PMID: 42165745. doi:10.1148/ryct.250404
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。