动态胸片评估法洛四联症术后肺动脉反流的新技术
本研究为回顾性观察性研究,纳入58例法洛四联症术后患者和14名健康志愿者,评估动态胸片(DCR)像素值变化指标与相位对比心脏MRI测量的肺动脉反流分数(PRF)的相关性。结果显示最大像素值变化斜率(Max PV Slope)与PRF相关性最高(R=0.87),鉴别重度PR(>30%)的AUC达0.98,敏感度93%、特异度94%。
要点
- DCR的Max PV Slope与MRI测得的PRF高度相关,可用于无创评估法洛四联症术后肺动脉反流。
- Max PV Slope鉴别重度PR(>30%)的AUC为0.98, cutoff为4.13%,敏感度93%、特异度94%。
- 重度PR患者的Max PV、Max PV Slope更高,Min PV Slope更低。
关键影像表现/征象
- 重度PR患者Max PV均值26.2%±8.1,非重度PR为14.1%±4.2,志愿者为9.4%±3.0(P<.001)。
- 重度PR患者Max PV Slope均值6.6±2.2(每帧百分比变化),非重度PR为2.9±0.9,志愿者为1.8±0.6(P<.001)。
- 重度PR患者Min PV Slope均值-7.2±2.0(每帧百分比变化),非重度PR为-4.6±1.6,志愿者为-3.5±1.4(P<.001)。
诊断标准与关键数值
- Max PV Slope与PRF相关性最高(R=0.87,P<.001)。
- Max PV Slope鉴别重度PR(>30%)的AUC为0.98(95%CI:0.94,1.0),cutoff为4.13%,敏感度93%,特异度94%。
局限性
- 回顾性研究设计。
- 样本量较小(患者58例,志愿者14名)。
- 单中心研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Cardiac MRI plays a key role in the assessment of pulmonary regurgitation (PR) after surgical repair of tetralogy of Fallot (TOF). However, its use may be limited by low availability, claustrophobia, or incompatible pacemakers or defibrillators. Purpose To evaluate the utility of dynamic chest radiography (DCR) for estimating PR after surgical TOF repair. Materials and Methods In this retrospective observational study, patients with repaired TOF who underwent DCR and phase-contrast cardiac MRI within 1 week between February 2018 and June 2024, and age- and sex-matched healthy volunteers, were enrolled. Temporal changes in pixel values of pulmonary arteries on DCR images were analyzed using specialized software. The maximum pixel value change (Max PV), maximum slope of pixel value change (Max PV Slope), and minimum slope of pixel value change (Min PV Slope) during a single cardiac cycle were calculated. Correlation between these indexes and PR fraction (PRF) at phase-contrast MRI and the ability of each index to differentiate severe PR (>30%) from nonsevere PR (≤30%) were assessed. Pearson correlation and receiver operating characteristic analyses were performed. Results The final study sample included 58 patients with repaired TOF (mean age, 30.6 years ± 10.3 [SD]; 29 [50%] male patients) and 14 healthy volunteers (mean age, 31.1 years ± 5.5; eight [57%] male individuals). Compared with patients with nonsevere PR and volunteers, patients with severe PR had the highest mean Max PV (severe PR: 26.2% ± 8.1; nonsevere PR: 14.1% ± 4.2; volunteers: 9.4% ± 3.0; P < .001), highest mean Max PV Slope (percentage change per frame) (severe PR: 6.6 ± 2.2; nonsevere PR: 2.9 ± 0.9; volunteers: 1.8 ± 0.6; P < .001), and lowest mean Min PV Slope (percentage change per frame) (severe PR: -7.2 ± 2.0; nonsevere PR: -4.6 ± 1.6; volunteers: -3.5 ± 1.4; P < .001). For patients with repaired TOF, all indexes were correlated with PRF; of these indexes, Max PV Slope had the highest correlation (R = 0.87; P < .001) and area under the receiver operating characteristic curve (0.98 [95% CI: 0.94, 1.0]; cutoff, 4.13%), yielding a sensitivity of 93% and specificity of 94%. Conclusion Max PV Slope from DCR showed high diagnostic value for PR severity in patients with repaired TOF. © RSNA, 2026 Supplemental material is available for this article. See also the editorial by Gerstner Saucedo in this issue.
引用
- Yamasaki Y, Sagiyama K, Hida T, et al. Novel Dynamic Chest Radiography Technique for Assessing Pulmonary Regurgitation in Repaired Tetralogy of Fallot. Radiology. 2026. PMID: 42153827. doi:10.1148/radiol.252344
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。