文献速递心血管外周血管技术与安全US

靶向微泡空化对糖尿病ApoE-/-小鼠主动脉粥样硬化斑块无治疗作用

Targeted microbubble cavitation has no therapeutic effect on atherosclerotic plaques of the aorta in diabetic ApoE-/- mice.
PubMed 文献 · Ultrasound Med Biol · 2026-03-22

在链脲佐菌素诱导的糖尿病ApoE-/-小鼠模型中,应用靶向ICAM-1和CD90的微泡联合1 MHz、100 kPa、1 kHz脉冲重复频率(10%占空比)的经胸超声进行空化治疗,4周后组织学分析显示斑块大小和斑块内炎症无显著变化,但治疗后3天内循环炎性经典单核细胞百分比显著暂时性增加。

要点

  • 靶向微泡空化未显著改变糖尿病小鼠主动脉根部粥样硬化斑块大小或斑块内炎症。
  • 治疗后3天内循环炎性经典单核细胞百分比显著增加,但为暂时性。
  • 斑块内CD45+白细胞和Ly6G+中性粒细胞呈阳性趋势但未达显著。

关键影像表现/征象

  • 靶向微泡空化未显著影响粥样硬化斑块大小。
  • 靶向微泡空化未显著影响斑块内炎症。
  • 斑块内CD45+白细胞和Ly6G+中性粒细胞呈阳性趋势但未达统计学显著。

诊断标准与关键数值

  • 靶向微泡为针对细胞间黏附分子-1(ICAM-1)和CD90的微泡。
  • 超声参数:1 MHz脉冲经胸超声,100 kPa峰值负声压,1 kHz脉冲重复频率,10%占空比,持续1分钟。

临床应用与阅片要点

  • 在糖尿病模型中,靶向微泡空化未显示斑块消退或抗炎效果,与non-DM模型结果不同。
  • 治疗后循环促炎单核细胞暂时性增加提示需关注空化的全身炎症效应。

局限性

  • 研究为动物模型(糖尿病ApoE-/-小鼠),结果不能直接外推至人类。
  • 仅评估主动脉根部斑块,未代表全主动脉粥样硬化负荷。
  • 观察期仅4周,长期效应未知。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIMS: Diabetes mellitus (DM) increases plaque instability via inflammation. Ultrasound-activated microbubble cavitation has previously reduced intra-plaque neovascularisation in non-DM models. Here we studied how ultrasound-activated microbubbles targeted against intercellular adhesion molecule-1 and CD90 affect atherosclerotic plaques in a DM model.

METHODS: DM was induced in C57BL/6 ApoE-/- mice via streptozotocin injection. Sixteen weeks later, either 5 × 107 targeted microbubbles or the vehicle was applied, followed by 1 min of 1 MHz pulsed thoracic ultrasound with 100 kPa peak negative acoustic pressure and a 1 kHz pulse repetition frequency (10% duty cycle). Aortic root plaque characteristics were examined via (immuno)histochemical analyses 4 wk post-treatment. Circulating monocyte subsets were assessed with flow cytometry in blood samples obtained within 3 d pre- and post-treatment, and 4 wk post-treatment.

RESULTS: Targeted microbubble cavitation did not significantly affect atherosclerotic plaque size or intra-plaque inflammation, despite a positive trend in intra-plaque CD45+ leukocytes and Ly6G+ neutrophils. Ultrasound-activated microbubble cavitation significantly increased the percentage of inflammatory classical monocytes within 3 d post-treatment.

CONCLUSIONS: Targeted microbubble cavitation induced a significant but temporary increase in circulating pro-inflammatory monocytes under mild exposure conditions in diabetic ApoE-/- mice without atherosclerotic plaque alterations.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Korn A, Simsek S, Fiet MD, et al. Targeted microbubble cavitation has no therapeutic effect on atherosclerotic plaques of the aorta in diabetic ApoE-/- mice. Ultrasound Med Biol. 2026. PMID: 42186180. doi:10.1016/j.ultrasmedbio.2026.02.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。