文献速递头颈神经MR

基于MRI的自动分割与多参数定量评估甲状腺眼病眶软组织受累

MRI-based automated segmentation and multiparametric quantification for assessing orbital soft tissue involvement in thyroid eye disease.
PubMed 文献 · Eur Radiol · 2026-05-06

本研究开发了深度学习框架TED-Net,用于自动分割眶软组织并提取定量影像生物标志物。多中心回顾性研究纳入330例TED患者开发模型,113例外部队列验证。TED-Net分割所有眶结构的Dice系数均>0.80,容积测量序列间一致性ICC=0.843。形态学与功能参数在轻度与中重度TED间差异显著(均p<0.05),联合容积-功能模型诊断眼眶受累的AUC=0.982,优于单纯容积模型(AUC=0.908)。

要点

  • TED-Net可自动分割眼外肌、泪腺、眶脂肪和眼球,Dice系数均>0.80。
  • 容积与功能参数联合模型评估TED眼眶受累的AUC达0.982。
  • 容积测量在不同序列间一致性高(ICC=0.843)。

局限性

  • 回顾性研究设计。
  • 原文未明确列出其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a deep learning-based multimodal framework for automated segmentation of orbital soft tissues and identify quantitative imaging biomarkers for precise grading of thyroid eye disease (TED).

MATERIALS AND METHODS: This retrospective multicenter study enrolled 330 TED patients from a primary center for model development and 113 patients from two external centers for validation. From the primary cohort, 182 mild and 138 moderate-to-severe TED were subsequently selected for further analysis. All subjects underwent 3 T MRI with water-fat separation and fat-suppressed (FS) T2 mapping sequences. TED-Net, a deep learning model integrating ConvNeXt and Transformer architectures, was developed to segment orbital structures including the extraocular muscles, lacrimal gland, orbital fat, and eyeball. The model automatically extracted both morphological parameters (volume and volume ratio) and functional parameters (water fraction, fat fraction, and FS T2 relaxation time), enabling quantitative comparison between mild and moderate-to-severe TED. Diagnostic performance for evaluating orbital involvement was assessed using receiver operating characteristic analysis and decision curve analysis.

RESULTS: TED-Net achieved Dice similarity coefficients > 0.80 across all orbital structures. Volumetric measurements showed high consistency among different sequences (intraclass correlation coefficient = 0.843). Significant differences in morphological and functional parameters were observed between mild and moderate-to-severe TED (all p < 0.05). The combined volumetric-functional model demonstrated superior diagnostic accuracy (area under the curve [AUC] = 0.982) over the volumetric model (AUC = 0.908).

CONCLUSIONS: TED-Net enables accurate automated segmentation and multiparametric quantification of orbital soft tissues, providing reliable imaging biomarkers for objective assessment of TED severity.

KEY POINTS: Question MRI-based quantitative metrics are essential for assessing orbital involvement in TED, but effective tools for rapid and accurate parameter extraction are currently lacking. Findings TED-Net achieved precise orbital segmentation and multiparametric quantification; the integration of volumetric and functional parameters yielded an AUC of 0.982 for evaluating orbital involvement. Clinical relevance The proposed TED-Net provides a reliable approach for quantifying orbital soft tissue involvement, and its clinical implementation enables more accurate assessment of TED severity.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhai L, Zeng Y, Chen Y, et al. MRI-based automated segmentation and multiparametric quantification for assessing orbital soft tissue involvement in thyroid eye disease. Eur Radiol. 2026. PMID: 42089968. doi:10.1007/s00330-026-12599-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。