中枢神经系统淋巴瘤血浆ctDNA阳性相关的MRI特征
本研究为回顾性单中心探索性研究,纳入25例中枢神经系统弥漫大B细胞淋巴瘤患者,共46次配对血浆ctDNA与增强脑MRI评估。结果显示,跨中线水肿与血浆ctDNA阳性几率显著降低相关(Firth惩罚OR 0.068,95%CI 0.00031-0.236),非增强肿瘤负荷≥34%与ctDNA阳性几率升高相关,但数据稀疏。结论需外部验证。
要点
- 跨中线水肿可能提示血浆ctDNA阳性几率较低,阅片时应关注水肿是否跨越中线。
- 非增强肿瘤负荷≥34%可能与ctDNA阳性几率升高相关,但证据有限。
- 血浆ctDNA阴性时需结合MRI特征解读,跨中线水肿可能部分解释假阴性。
关键影像表现/征象
- 跨中线水肿在31个可重复MRI特征中入选频率最高(55.8%)。
- 高非增强肿瘤负荷(≥34%)与ctDNA阳性几率升高相关,但数据稀疏。
- 占位效应与ctDNA阳性几率降低相关,但数据稀疏。
诊断标准与关键数值
- ctDNA阳性定义为变异等位基因频率≥0.5%。
- 跨中线水肿与血浆ctDNA阳性几率降低相关:Firth惩罚OR 0.068,患者水平聚类bootstrap 95%CI 0.00031-0.236,Pr[OR<1]=1.000。
- MRI特征保留标准:读者间kappa/加权kappa≥0.60或ICC≥0.75。
局限性
- 回顾性单中心设计,样本量小(25例患者,46次评估)。
- 探索性、假设生成性研究,结果需外部验证。
- 部分分析(如非增强肿瘤负荷和占位效应)存在数据稀疏模式。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Peripheral-blood circulating tumor DNA (ctDNA) detectability is inconsistent in central nervous system lymphoma (CNSL), so negative plasma findings are hard to interpret. This exploratory, hypothesis-generating study tested whether routinely available, reproducible multiparametric Magnetic resonance imaging (MRI) features are associated with plasma ctDNA positivity across repeated paired MRI-plasma assessments.
MATERIALS AND METHODS: In this retrospective single-center study, 25 patients with diffuse large B-cell lymphoma involving the CNS (primary or secondary) contributed 46 paired plasma ctDNA and contrast-enhanced brain MRI evaluations. MRI features were prospectively defined and independently annotated by two blinded radiologists; features were retained only with substantial inter-reader agreement (kappa/weighted kappa ≥0.60) or good ICC (≥0.75). Associations with ctDNA positivity (variant allele frequency ≥0.5%) were screened using logistic generalized estimating equations (GEEs) for within-patient correlation, prioritized by patient-level bootstrap stability selection with L1-penalized logistic regression, and summarized in adjusted multivariable models (age at CNS diagnosis and disease type).
RESULTS: Among 31 reproducible MRI-derived features, edema crossing the midline had the highest selection frequency (55.8%). In the primary adjusted multivariable model, edema crossing the midline was linked to markedly lower odds of plasma ctDNA positivity (Firth-penalized OR 0.068). To address within-patient correlation from repeated evaluations, uncertainty was estimated by patient-level cluster bootstrap (B = 1000; percentile method), giving a 95% confidence interval of 0.00031-0.236 with complete directional consistency across resamples (Pr[OR < 1] = 1.000; bootstrap failure rate 0.3%). Sensitivity analyses indicated that high non-contrast-enhancing tumor (nCET) burden (≥34%) was associated with higher ctDNA positivity odds, while mass effect was associated with lower odds, though both showed sparse-data patterns.
CONCLUSION: Reproducible MRI features, especially edema crossing the midline, were inversely associated with plasma ctDNA positivity across repeated evaluations. Patient-level cluster-bootstrap inference supported the robustness of the observed association. External validation in larger cohorts is needed before clinical implementation.
引用
- Li Y, Xiu B, Wang W, et al. MRI Features Associated with Plasma ctDNA Positivity in Central Nervous System Lymphoma. Acad Radiol. 2026. PMID: 42086450. doi:10.1016/j.acra.2026.04.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。