基于平扫双能CT电子密度图检测扁桃体周围脓肿的可行性

Feasibility of electron density map derived from unenhanced dual-energy CT for detecting peritonsillar abscess.
PubMed 文献 · Neuroradiology · 2026-03-27

本研究回顾性纳入89例临床疑似扁桃体周围脓肿患者,评估平扫双能CT生成的电子密度图(ED map)检测脓肿的可行性。以脓液引流为最终诊断,ED map和40-keV虚拟单能图的诊断准确率显著高于常规120-kVp图像。ED map的诊断信心和脓肿病灶对比噪声比均显著高于常规图像。

要点

  • ED map诊断准确率75.3%,显著高于常规120-kVp图像的65.2%。
  • ED map诊断信心评分(3.49±0.83)和CNR(3.42±3.19)均显著高于常规图像。
  • 平扫双能CT有望无需增强即可检测扁桃体周围脓肿。

关键影像表现/征象

  • ED map和40-keV VMI的诊断准确率分别为75.3%和73.0%,均显著高于常规120-kVp图像的65.2%(p=.035和.039)。
  • ED map的诊断信心评分(3.49±0.83)显著高于常规120-kVp图像(2.96±0.93,p<.001)。
  • 确诊脓肿病例中,ED map的脓肿病灶CNR(3.42±3.19)显著高于常规120-kVp图像(0.96±0.78,p<.001)。

诊断标准与关键数值

  • 采用4分诊断信心评分:4=极可能,3=可能,2=不太可能,1=极不可能;评分3和4视为脓肿阳性。
  • ED map诊断准确率75.3%,40-keV VMI为73.0%,常规120-kVp图像为65.2%。

临床应用与阅片要点

  • 平扫双能CT的ED map可作为疑似扁桃体周围脓肿的检测工具,减少对增强CT的依赖。
  • 阅片时关注ED map上脓肿病灶的对比噪声比,其显著优于常规平扫图像。

局限性

  • 回顾性单中心研究,样本量89例。
  • 最终诊断基于脓液引流,可能未覆盖所有疑似病例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the feasibility of ED map derived from unenhanced DECT for detecting peritonsillar abscess.

METHODS: This retrospective study included patients with clinically suspected peritonsillar abscess who underwent DECT. Two independent radiologists evaluated the presence of peritonsillar abscess on unenhanced conventional 120-kVp images (CTconv), 70- and 40-keV virtual monochromatic images (VMIs), ED map, and contrast-enhanced CT (CECT), using a 4-point diagnostic confidence, scored as follows: 4, highly likely; 3, likely; 2, unlikely; and 1, highly unlikely. Scores of 3 and 4 were considered positive for abscess. The final diagnosis of peritonsillar abscess was based on pus drainage. The sensitivity, specificity, and diagnostic accuracy were calculated for each image, and diagnostic accuracies were compared among image types by McNemar test. In confirmed abscess cases, the contrast-to-noise ratio (CNR) of abscess lesions was calculated. The diagnostic confidence score and CNR were then compared between unenhanced CTconv and DECT images using the Wilcoxon signed-rank test and paired t-test, respectively.

RESULTS: Totally, 89 patients (mean age, 39.3 ± 19.4 years) were evaluated. The accuracy of ED maps (75.3%) and 40-keV VMI (73.0%) was significantly higher than that of CTconv (65.2%; p = .035 and .039, respectively). Both diagnostic confidence score and CNR were significantly higher on ED maps than CTconv (diagnostic confidence score: 3.49 ± 0.83 vs. 2.96 ± 0.93; CNR: 3.42 ± 3.19 vs. 0.96 ± 0.78; both p < .001).

CONCLUSION: Unenhanced DECT, especially ED map, may enable efficient detection of peritonsillar abscess without contrast agents.

SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at https://doi.org/10.1007/s00234-026-03987-w.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Nagano H, Takumi K, Nagano E, et al. Feasibility of electron density map derived from unenhanced dual-energy CT for detecting peritonsillar abscess. Neuroradiology. 2026. PMID: 41973105. doi:10.1007/s00234-026-03987-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。