文献速递腹部CT

深度学习重建用于结肠癌40-keV虚拟单能CT:图像质量与边缘锐度评估

Deep learning reconstruction for 40-keV virtual monoenergetic CT of colon cancer: evaluation of image quality and edge sharpness.
PubMed 文献 · Abdom Radiol (NY) · 2026-04-06

回顾性纳入60例结肠腺癌患者,双能CT低碘方案(1.0 mL/kg)门静脉期重建40 keV图像,比较ASIR-V 50%、DLIR-M与DLIR-H。DLIR-H在所有解剖目标上噪声最低、CNR最高,主客观图像质量及区域淋巴结显示评分最优,ERD在各算法间稳定,仅ERS略低于ASIR-V 50%。

要点

  • 40-keV VMI联合DLIR-H可显著降低噪声并提高结肠癌肿瘤CNR,利于低碘方案图像展示。
  • DLIR-H对区域淋巴结显示主观评分最高,有助于淋巴结的观察与报告。
  • DLIR-H存在轻度边缘平滑效应(ERS略降),但ERD稳定,解剖边缘整体保持良好。

诊断标准与关键数值

  • DLIR-H在所有解剖目标上图像噪声最低、CNR最高,与DLIR-M及ASIR-V 50%比较均P<0.001。
  • 结肠肿瘤CNR:DLIR-H为5.4±2.2,较ASIR-V 50%的3.0±1.1高80%(P<0.001)。
  • ERS中位数ASIR-V 50%为108.3 HU/mm,高于DLIR-H的101.5 HU/mm(P<0.001)。
  • ERD在各算法间保持稳定,中位数均为2.5 mm(两两比较P>0.05)。
  • 主观评分:DLIR-H整体图像质量与区域淋巴结显示中位数分别为5.0和4.5,ASIR-V 50%均为3.0(均P<0.001)。

局限性

  • 为回顾性研究,样本量60例,结论需前瞻性诊断准确性试验验证。
  • 原文指出DLIR-H存在轻度客观边缘平滑效应(ERS略低于ASIR-V 50%)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Virtual monoenergetic imaging (VMI) at 40 keV improves iodine attenuation in colon cancer CT but is constrained by severe image noise. Deep learning image reconstruction (DLIR) may address this limitation, but its effect on anatomical edge preservation across multiple targets requires investigation.

PURPOSE: To evaluate the impact of DLIR on objective and subjective image quality of 40-keV VMIs in colon adenocarcinoma, with emphasis on the trade-off between noise reduction and edge definition.

METHODS: In this completed retrospective study (patient enrollment window: May 2024 to February 2025), 60 patients (mean age, 62.8 years ± 15.1; 34 men) with confirmed colon adenocarcinoma underwent dual-energy CT using a low-iodine protocol (1.0 mL/kg). Portal venous phase data were reconstructed at 40 keV using adaptive statistical iterative reconstruction-V (ASIR-V) 50%, medium-strength DLIR (DLIR-M), and high-strength DLIR (DLIR-H). Objective metrics, including contrast-to-noise ratio (CNR), edge rise distance (ERD), and edge rise slope (ERS), were measured. Two radiologists independently scored five qualitative categories, including regional lymph node visualization, using a 5-point Likert scale.

RESULTS: DLIR-H yielded the lowest image noise and highest CNR across all anatomical targets compared with DLIR-M and ASIR-V 50% (all P < 0.001). For colon tumors, the CNR of DLIR-H (5.4 ± 2.2) was 80% higher than that of ASIR-V 50% (3.0 ± 1.1, P < 0.001). Although ASIR-V 50% maintained a higher ERS than DLIR-H (median, 108.3 vs. 101.5 HU/mm; P < 0.001), the ERD remained highly stable across all algorithms (median, 2.5 mm; pairwise P > 0.05). Subjectively, DLIR-H received the highest scores for overall image quality and regional lymph node visualization (median, 5.0 and 4.5, respectively, vs. 3.0 for both in ASIR-V 50%; all P < 0.001).

CONCLUSION: In 40-keV virtual monoenergetic CT of colon cancer, DLIR-H significantly improves objective and subjective image quality for tumors, vessels, and lymph nodes. While a minor objective edge-smoothing effect exists, DLIR-H provides an optimal balance between robust noise suppression and anatomical clarity. Although these findings suggest the potential to facilitate low-iodine spectral protocols, future diagnostic accuracy trials are required to confirm their true clinical impact.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Bao Y, Long J, Wang Z, et al. Deep learning reconstruction for 40-keV virtual monoenergetic CT of colon cancer: evaluation of image quality and edge sharpness. Abdom Radiol (NY). 2026. PMID: 41940980. doi:10.1007/s00261-026-05494-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。