不同人工智能辅助压缩感知加速因子在内耳重T2加权成像中的对比研究
该前瞻性研究纳入40名健康志愿者,比较不同加速因子(2.7、3.87、4.68、5.52)的人工智能辅助压缩感知(ACS)与无加速参考组在内耳重T2加权三维快速自旋回波序列中的图像质量。结果显示ACS3.87组成像质量优于参考组及更高加速因子组,信噪比和对比噪声比最优,采集时间缩短至参考组的28.81%,推荐临床使用约3.5-4倍加速因子。
要点
- 推荐内耳重T2加权成像采用约3.5-4倍加速因子的ACS,可显著缩短采集时间并保持优良图像质量。
- ACS3.87组的SNR和CNR优于其他所有组,边缘锐度仅显著优于参考组。
- 加速因子过高(4.68、5.52)会降低图像质量,不宜盲目追求更快采集。
关键影像表现/征象
- ACS3.87组图像质量主观评分优于参考组及ACS4.68、ACS5.52组,与ACS2.7组无显著差异。
- ACS3.87组的SNR和CNR优于其他所有组。
- ACS3.87组边缘锐度仅显著优于参考组。
诊断标准与关键数值
- 图像质量采用四分法主观评估。
- ACS2.7、ACS3.87、ACS4.68、ACS5.52组采集时间分别缩短至参考组(354秒)的39.83%、28.81%、23.73%、20.62%。
临床应用与阅片要点
- 日常内耳重T2加权成像可优先选择加速因子约3.87的ACS,以平衡图像质量与采集时间。
- 避免使用4.68及以上加速因子,以免图像质量下降影响细微结构评估。
局限性
- 研究仅纳入健康志愿者,未在患者群体中验证。
- 样本量较小(40例),单中心前瞻性设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: Artificial intelligence (AI)-assisted compressed sensing (ACS) is a cutting-edge magnetic resonance imaging (MRI) acceleration technique based on deep learning. High-quality imaging of the inner ear suffers from lengthy acquisition time due to intricate and fine structure. The study aimed to compare the image quality of heavily T2-weighted inner ear imaging among ACS groups with different accelerated factors (AFs).
MATERIALS AND METHODS: A total of 40 healthy volunteers were prospectively included. Using a heavily T2-weighted three-dimensional fast spin-echo sequence, images were acquired in a reference group (without acceleration) and four ACS groups, with AFs of 2.7, 3.87, 4.68, and 5.52, respectively. Image quality was qualitatively assessed using a four-point scale. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge sharpness were compared across groups.
RESULTS: Compared with the reference group (acquisition time: 354 secs), the acquisition times for the ACS2.7, ACS3.87, ACS4.68, and ACS5.52 groups were shortened to 39.83%, 28.81%, 23.73%, and 20.62%, respectively. The ACS3.87 group demonstrated superior imaging quality compared with the reference group and the ACS4.68 and ACS5.52 groups, but showed no significant difference from the ACS2.7 groups. The ACS3.87 group outperformed all other groups with respect to SNR and CNR. Regarding edge sharpness, it was only significantly better than that of the reference group.
CONCLUSION: The ACS3.87 group improved imaging quality while substantially reduced acquisition time compared with other ACS groups. An AF of approximately 3.5- to 4-fold is recommended for clinical application in heavily T2-weighted inner ear imaging.
引用
- Wang W, Yang S, Ning K, et al. Comparative study of different artificial intelligence (AI)-assisted compressed sensing factors in inner ear heavily T2-weighted imaging. Clin Radiol. 2026. PMID: 41955645. doi:10.1016/j.crad.2026.107311
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。