文献速递神经外周血管MRDSA

非对比4D-MRA评估颈内动脉闭塞时Willis环侧支循环:与TOF-MRA、CE-MRA及DSA的比较

Evaluation of collateral circulation through the Circle of Willis in internal carotid artery occlusion using non-contrast 4D-MRA: a comparative analysis of 4D-PACK, 4D-S-PACK, TOF-MRA, CE-MRA, and DSA.
PubMed 文献 · Br J Radiol · 2026-01-01

前瞻性纳入19例患者共21处颈内动脉闭塞,以DSA为参考标准,比较4D-PACK联合4D-S-PACK、TOF-MRA和CE-MRA评估Willis环解剖及侧支通路模式的诊断准确性。联合4D-MRA对颈内动脉闭塞检出准确率100.0%,Willis环解剖准确率98.2%,侧支通路评估敏感度95.2%、特异度100.0%、准确率98.2%,优于TOF-MRA和CE-MRA。采用200、800和2000 ms三个时间点的4D-S-PACK可缩短扫描时间并保持准确的血流方向评估。

要点

  • 联合4D-PACK与4D-S-PACK评估颈内动脉闭塞侧支通路准确率98.2%,优于TOF-MRA的86.0%和CE-MRA的91.2%。
  • 联合4D-MRA检出颈内动脉闭塞准确率100.0%,Willis环解剖评估准确率98.2%。
  • 4D-S-PACK使用200、800、2000 ms三个时间点可在缩短扫描时间的同时准确判断血流方向。

核心结论

  • 联合非对比4D-PACK与4D-S-PACK可全面评估颈内动脉闭塞、Willis环形态及侧支循环,是替代DSA的有前景的无创方法。
  • 联合4D-MRA在侧支通路评估准确性上优于标准MRA技术(TOF-MRA和CE-MRA)。

研究设计与样本

  • 前瞻性研究,纳入19例颈内动脉闭塞患者共21处闭塞,在同一周内完成多对比MRA(3D TOF-MRA、CE-MRA、4D-PACK、4D-S-PACK)及DSA检查。
  • 以DSA为参考标准,独立评估各MRA技术对颈内动脉闭塞、Willis环解剖及侧支通路模式的诊断准确性。
  • 4D-MRA采集时间点包括100、200、500、800、1200、1600和2000 ms,并评估最佳4D-S-PACK协议及其判断Willis环血流方向的能力。

诊断标准与关键数值

  • 联合4D-MRA(4D-PACK加4D-S-PACK)检出颈内动脉闭塞的准确率为100.0%,评估Willis环解剖的准确率为98.2%。
  • 联合4D-MRA评估侧支通路的敏感度95.2%、特异度100.0%、准确率98.2%。
  • TOF-MRA评估侧支通路的敏感度85.7%、特异度86.1%、准确率86.0%。
  • CE-MRA评估侧支通路的敏感度100.0%、特异度86.1%、准确率91.2%。
  • 4D-S-PACK采用200、800和2000 ms三个时间点可缩短扫描时间并保持准确的血流方向评估。

临床应用与阅片要点

  • 对颈内动脉闭塞患者,联合4D-PACK与4D-S-PACK可无创评估Willis环侧支通路,减少对DSA的依赖。
  • 4D-S-PACK选择200、800和2000 ms三个时间点可在保证血流方向判断准确性的同时缩短扫描时间。

局限性

  • 样本量较小(19例患者、21处闭塞),为单中心前瞻性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to evaluate the accuracy of non-contrast 4D-magnetic resonance angiography (4D-MRA) techniques (4D-PACK and 4D-S-PACK) in assessing collateral circulation via the Circle of Willis (CoW) in patients with internal carotid artery occlusion (ICAO), using digital subtraction angiography (DSA) as the reference standard.

METHODS: In this prospective study, patients with ICAO underwent multi-contrast MRA (3D TOF-MRA, CE-MRA, 4D-PACK, and 4D-S-PACK) and DSA within 1 week. Using DSA as the reference, the diagnostic accuracy of each MRA technique was independently assessed for ICAO occlusion, CoW anatomy, and collateral pathway patterns. The 4D-MRA acquisitions included time points of 100, 200, 500, 800, 1200, 1600, and 2000 ms. Additionally, the optimal 4D-S-PACK protocol and its capacity to determine CoW flow direction were evaluated.

RESULTS: A total of 19 patients with 21 ICAOs were included. Combined 4D-MRA (4D-PACK plus 4D-S-PACK) demonstrated high diagnostic accuracy for detecting ICAO (100.0%) and CoW anatomy (98.2%). In assessing collateral pathways, combined 4D-MRA (sensitivity 95.2%, specificity 100.0%, accuracy 98.2%) outperformed TOF-MRA (sensitivity 85.7%, specificity 86.1%, accuracy 86.0%) and CE-MRA (sensitivity 100.0%, specificity 86.1%, accuracy 91.2%). Using 3 time points (200, 800, and 2000 ms), 4D-S-PACK significantly reduced scan time while maintaining accurate flow direction assessment.

CONCLUSIONS: Combined non-contrast 4D-PACK and 4D-S-PACK is a promising, non-invasive alternative for comprehensively evaluating ICAO, CoW morphology, and collateral circulation.

ADVANCES IN KNOWLEDGE: This study establishes that a combined non-contrast 4D-MRA protocol surpasses standard MRA techniques in collateral pathway accuracy, providing a viable, non-invasive alternative to DSA.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang J, Wang W, Chen Z, et al. Evaluation of collateral circulation through the Circle of Willis in internal carotid artery occlusion using non-contrast 4D-MRA: a comparative analysis of 4D-PACK, 4D-S-PACK, TOF-MRA, CE-MRA, and DSA. Br J Radiol. 2026. PMID: 41984791. doi:10.1093/bjr/tqag081

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。