柔性线圈联合PROPELLER序列在侧卧位腰椎MRI中的图像质量评估:与常规仰卧位MRI比较
本研究纳入35例需侧卧位腰椎MRI且仰卧位时NRS疼痛评分≥5的患者,比较仰卧位FSE、侧卧位FSE及侧卧位PROPELLER序列的图像质量。结果显示侧卧位腰椎MRI使用柔性线圈临床可行,图像质量可接受;PROPELLER序列可提高侧卧位轴位T2WI的脑脊液SNR。
要点
- 侧卧位腰椎MRI使用柔性线圈临床可行,图像质量可接受。
- 轴位T2WI上PROPELLER序列脑脊液SNR高于侧卧位FSE。
- 主观图像质量在仰卧FSE、侧卧FSE及侧卧PROPELLER间无统计学差异。
局限性
- 单中心研究,样本量35例。
- 研究时间窗较短(2025年2月1日至3月11日)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate image quality of decubitus lumbar spine MRI using a flexible coil with or without Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) sequence compared to that of the conventional supine lumbar spine MRI.
MATERIALS AND METHODS: This study was conducted on patients who underwent decubitus lumbar spine MRI applying a flexible coil at a single center between February 1 and March 11, 2025, and had a Numeric Rating Scale (NRS) pain score ≥ 5, while examining supine MRI. Signal-to-noise ratio (SNR) in T2-weighted fast-spin-echo (FSE) sequence for supine, decubitus, and PROPELLER sequence at decubitus position were measured and compared using the Wilcoxon signed-rank test. Two radiologists independently evaluated the subjective image quality of each spine MRI.
RESULTS: A total of 35 patients (mean age, 66 ± 13 years) were included in our study. On T2-weighted sagittal images, cerebrospinal fluid (CSF) SNR was highest in the supineFSE (589.3, 95% CI: 482.1-695.1) and significantly lower in both decubitusFSE (431.2, 95% CI: 365.9-479.9) and decubitusPROPELLER (417.8, 95% CI: 389.2-439.1) (p < 0.001). On T2-weighted axial images, SNRCSF values of supineFSE (284.6, 95% CI: 256.4-331.0) and decubitusPROPELLER (245.0, 95% CI: 215.7-336.1) were both statistically higher than that of decubitusFSE (176.1, 95% CI: 135.9-209.2) (p < 0.001). In qualitative analysis, there was no statistical difference across supineFSE, decubitusFSE, and decubitusPROPELLER.
CONCLUSION: Image quality of decubitus lumbar spine MRI using a flexible coil was clinically feasible with acceptable image quality. PROPELLER sequence improved SNRCSF on axial images in decubitus position.
引用
- Kang SM, Do Y, Chee CG, et al. Image quality evaluation of decubitus lumbar spine MRI using a flexible coil and PROPELLER sequence: comparison with conventional supine MRI. Skeletal Radiol. 2026. PMID: 41973207. doi:10.1007/s00256-026-05215-1