文献速递乳腺技术与安全US

超声弹性成像影像组学:BI-RADS 4类乳腺肿块良恶性鉴别的新方法

Ultrasound Elastography Radiomics: A Novel Approach for Benign-Malignant Differentiation of BI-RADS Category 4 Breast Masses.
PubMed 文献 · Acad Radiol · 2026-03-30

本研究纳入720例BI-RADS 4类乳腺病变患者(训练集504例/内部验证集216例)及102例外部队列,基于超声和弹性成像提取影像组学特征构建联合模型。联合模型内部验证AUC达0.926,优于超声影像组学模型(AUC=0.726)、弹性成像影像组学模型(AUC=0.853)及BI-RADS分类(AUC=0.869),外部验证结果相似。联合模型在低级别恶性亚组(4A、4B)中表现出高诊断特异度,有助于减少不必要的空心针穿刺活检。

要点

  • 联合超声与弹性成像影像组学模型可无创鉴别BI-RADS 4类乳腺肿块良恶性。
  • 联合模型内部验证AUC为0.926,优于单一影像组学模型及BI-RADS分类。
  • 联合模型在BI-RADS 4A、4B低级别恶性亚组中诊断特异度高,有望减少活检。

核心结论

  • 联合超声与弹性成像影像组学模型对BI-RADS 4类乳腺肿块良恶性鉴别诊断性能优于单一影像组学模型及BI-RADS分类,外部验证结果相似。
  • 联合模型校准良好且具有临床价值,在低级别恶性亚组(4A、4B)中诊断特异度高,可减少不必要的空心针穿刺活检。

研究设计与样本

  • 研究为诊断模型开发与验证研究,共纳入720例BI-RADS 4类乳腺病变患者(训练集504例,内部验证集216例)及102例外部队列。
  • 从Pyradiomics提取的623个影像组学特征中,经Z-score标准化、组内相关系数分析(>0.9)及最大相关最小冗余滤波后保留9个稳定特征。
  • 构建三个逻辑回归模型(超声影像组学、弹性成像影像组学及联合模型),采用10折交叉验证进行开发与验证。

诊断标准与关键数值

  • 内部验证队列中,联合模型AUC=0.926,优于超声影像组学模型(AUC=0.726,Z=5.643,P<0.01)、弹性成像影像组学模型(AUC=0.853,Z=3.021,P=0.003)及BI-RADS分类(AUC=0.869,Z=2.051,P=0.040)。
  • 联合模型在低级别恶性亚组(BI-RADS 4A、4B)中表现出高诊断特异度。

临床应用与阅片要点

  • 对于BI-RADS 4类乳腺肿块,可结合超声与弹性成像影像组学联合模型辅助良恶性鉴别,尤其在4A、4B亚组中高特异度有助于减少不必要的空心针穿刺活检。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop a non-invasive, accurate diagnostic model by integrating ultrasound radiomics with Ultrasound Elastography (UE) for BI-RADS category 4 breast masses, addressing limitations of current diagnostic methods.

METHODS: A total of 720 patients with BI-RADS category 4 breast lesions (504 for training/216 for internal validation) and 102 external validation patients were enrolled. From the 623 radiomic features extracted by Pyradiomics, 9 stable features were retained after Z-score standardization, intraclass correlation coefficient analysis (>0.9), and max-relevance and min-redundancy filtering. Three Logistic Regression models (ultrasound radiomics, UE radiomics, and the combined model) were developed and validated using 10-fold cross-validation.

RESULTS: In the internal validation cohort, the combined model (AUC = 0.926) achieved superior diagnostic performance compared to the ultrasound radiomics model (AUC = 0.726, Z = 5.643, P < 0.01), UE radiomics model (AUC = 0.853, Z = 3.021, P = 0.003), and the BI-RADS category (AUC = 0.869, Z = 2.051, P = 0.040). Similar results were observed in the external validation cohort. The combined model demonstrated favorable calibration performance and clinical value, as evidenced by calibration curves and decision curve analysis. The combined radiomic model exhibited high diagnostic specificity in the low-grade malignant cohort (4A, 4B).

CONCLUSION: For BI-RADS category 4 breast masses, the combined radiomic model enables accurate and non-invasive differentiation of benign and malignant lesions, reduces unnecessary core needle biopsies, and provides a valuable tool for personalized clinical decision-making and breast cancer management.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Yang F, Liu CW, Zhang D, et al. Ultrasound Elastography Radiomics: A Novel Approach for Benign-Malignant Differentiation of BI-RADS Category 4 Breast Masses. Acad Radiol. 2026. PMID: 41916803. doi:10.1016/j.acra.2026.03.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。