简化乳腺MRI评估新辅助化疗后治疗反应
本回顾性单中心研究纳入478例乳腺癌患者,比较简化MRI与全方案MRI评估新辅助化疗后病理完全缓解的诊断性能。简化MRI在敏感度、阴性预测值、阳性预测值和总体准确率上与全方案MRI无差异,但特异度较低;阅片时间显著缩短。
要点
- 简化MRI评估新辅助化疗后pCR的敏感度与全方案MRI相当,但特异度较低。
- 简化MRI阅片时间中位数39-44秒,显著短于全方案MRI的42-64秒。
- 简化MRI方案包含轴位T2加权序列及增强前后早期T1加权序列。
局限性
- 回顾性单中心设计
- 简化MRI序列仅包含轴位T2加权及增强前后早期T1加权序列
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Abbreviated MRI offers faster interpretation and shorter acquisition times than full-protocol MRI. Purpose To assess the diagnostic performance of abbreviated breast MRI compared with full-protocol MRI in determining pathologic complete response (pCR) after neoadjuvant chemotherapy (NAC) in patients with breast cancer. Materials and Methods This retrospective, single-center study included patients with breast cancer who underwent full-protocol MRI before and after NAC from January 2016 to May 2020, followed by surgical resection. Three readers independently interpreted abbreviated MRI data, which included an axial T2-weighted sequence and precontrast and early postcontrast T1-weighted sequences. After a 4-week washout period, the readers interpreted the full-protocol MRI data. Response was classified as complete, partial, stable, or progressive disease. Interpretation times were recorded, and residual enhancement was measured (longest and shortest orthogonal lesion diameters). For statistical analysis, abbreviated MRI and full-protocol MRI were compared using two pCR definitions: the absence of invasive cancer and the absence of both invasive cancer and ductal carcinoma in situ. Statistical tests included generalized estimating equation models, Wilcoxon rank sum tests, and Pearson correlation. Results The study sample included 478 patients (mean age, 51 years ± 12 [SD]; all female). Full-protocol MRI yielded higher specificity than abbreviated MRI did (82.1% vs 85.4% using pCR definition 1; 85.4% vs 88.6% using pCR definition 2; P = .047 for both). There was no evidence of a difference in sensitivity, negative predictive value, positive predictive value, or overall accuracy between abbreviated MRI and full-protocol MRI across pCR definitions and reader (all P > .22). The median interpretation times for abbreviated MRI and full-protocol MRI were 39-44 seconds and 42-64 seconds, respectively (all P < .001). Conclusion Abbreviated MRI offered a time-efficient alternative for assessing the response to neoadjuvant chemotherapy, with similar diagnostic performance to full-protocol MRI in all metrics except specificity. © RSNA, 2026 Supplemental material is available for this article. See also the editorial by Slanetz and Yeh in this issue.
引用
- Lo Gullo R, Surovitsky M, Kim D, et al. Abbreviated MRI for the Evaluation of Treatment Response in Patients Undergoing Neoadjuvant Chemotherapy for Breast Cancer. Radiology. 2026. PMID: 41979460. doi:10.1148/radiol.252413
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。