文献速递妇产影像泌尿生殖MR

MRS检测富马酸峰诊断子宫平滑肌瘤FH缺陷的前瞻性研究

Accuracy of Magnetic Resonance Spectroscopy-Detected Fumarate Peak for Diagnosing Fumarate Hydratase Deficiency in Uterine Leiomyomas: A Prospective Study.
PubMed 文献 · Korean J Radiol · 2026-04-01

该前瞻性研究评估了磁共振波谱(MRS)检测富马酸峰在鉴别富马酸水合酶缺陷型(FH-d)子宫平滑肌瘤与FH保留型平滑肌瘤中的诊断性能。研究纳入360例超声检出平滑肌瘤(直径≥3 cm,年龄20-40岁)的连续参与者,以免疫组化2-SC为参考标准。MRS阳性富马酸峰诊断FH-d平滑肌瘤的敏感度为94.6%、特异度为99.7%、准确率为99.2%,显著优于其他MRI特征(P ≤ 0.002)。

要点

  • MRS检测富马酸峰可作为诊断FH-d子宫平滑肌瘤的影像生物标志物。
  • 最佳MRS参数为回波时间140 ms、平均次数256。
  • MRS诊断性能显著优于常规MRI特征(P ≤ 0.002)。

关键影像表现/征象

  • MRS可评估胆碱峰和富马酸峰,分类为阳性、阴性或技术失败(TF)。
  • T1WI、T2WI和扩散加权图像按高信号或低信号解读。
  • 获取强化率和表观扩散系数。

诊断标准与关键数值

  • MRS最佳参数:回波时间(TE)= 140 ms,平均次数256。
  • 排除6例技术失败后,阳性富马酸峰诊断FH-dUL的敏感度94.6%(35/37)、特异度99.7%(316/317)、准确率99.2%(351/354)。
  • MRS诊断性能显著优于其他MRI特征(P ≤ 0.002)。

临床应用与阅片要点

  • 对超声检出直径≥3 cm的子宫平滑肌瘤、年龄20-40岁患者,可考虑MRS检测富马酸峰辅助诊断FH-dUL。
  • 注意技术失败(TF)病例需单独分析,不纳入主要诊断准确性计算。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic performance of magnetic resonance spectroscopy (MRS) in discriminating fumarate hydratase-deficient (FH-d) uterine leiomyomas (ULs) from FH-preserved ULs.

MATERIALS AND METHODS: This study consisted of three stages, with independent cohorts recruited for each stage: 1) sample-size estimation was retrospectively performed on UL specimens (diameter ≥3 cm; age, 20-40 years) from our database with immunohistochemistry (IHC) for 2-succinocysteine (2-SC) as the reference, without genetic testing, 2) MRS sequence optimization in confirmed FH germline mutation participants with ultrasound-detected ULs (diameter ≥3 cm), without IHC analysis, and 3) prospective diagnostic test accuracy was evaluated in consecutive participants with ultrasound-detected ULs (diameter ≥3 cm; age, 20-40 years), using IHC for 2-SC for determining the FH status and subsequent genetic testing in those with positive 2-SC results to identify whether FH mutations were germline or somatic in origin. The choline and fumarate peaks in MRS were classified as positive, negative, or technical failure (TF). TFs were analyzed separately and excluded from the primary diagnostic accuracy calculations. T1-, T2-, and diffusion-weighted images were interpreted as hyperintense or hypointense. The enhancement rate and apparent diffusion coefficient were also acquired. Diagnostic performance was compared between MRS and various magnetic resonance imaging (MRI) features.

RESULTS: The optimal MRS parameters for the fumarate peak were echo time (TE) = 140 ms and an average of 256. Among the 360 prospective participants, 37 were confirmed to have FH-dULs. MRS showed positive fumarate peaks in 35 of 37 FH-dULs. After excluding six TFs, the positive fumarate peak on MRS showed 94.6% (35/37) sensitivity, 99.7% (316/317) specificity, and 99.2% (351/354) accuracy, all of which were significantly superior to those of other MRI features (P ≤ 0.002).

CONCLUSION: A positive fumarate peak on MRS may be a useful imaging biomarker for diagnosing FH-dULs.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Liu G, Yu W, Pan S, et al. Accuracy of Magnetic Resonance Spectroscopy-Detected Fumarate Peak for Diagnosing Fumarate Hydratase Deficiency in Uterine Leiomyomas: A Prospective Study. Korean J Radiol. 2026. PMID: 41974528. doi:10.3348/kjr.2025.1516

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。