妊娠期糖尿病视网膜成像的系统综述
该系统综述纳入10项研究,比较妊娠期糖尿病(GDM)与非GDM孕妇的视网膜结构与血管差异。视网膜眼底摄影和横断面OCT提示GDM孕妇视网膜静脉参数增加、动静脉比降低;结构OCT显示RNFL厚度降低或相似,GCL、内丛状层和黃斑RNFL厚度组合降低;OCTA的浅层和深层毛细血管丛血管密度结果不一致。现有证据不一致,不足以明确GDM相关视网膜改变。
要点
- GDM孕妇视网膜静脉参数增加、动静脉比降低,眼底摄影和横断面OCT可观察。
- 结构OCT显示GDM孕妇RNFL厚度降低或相似,GCL、内丛状层和黃斑RNFL厚度组合降低。
- OCTA浅层和深层毛细血管丛血管密度在GDM中降低或与对照组无显著差异,证据不一致。
关键影像表现/征象
- 视网膜眼底摄影和横断面OCT显示GDM孕妇视网膜静脉参数增加、动静脉比降低,视网膜小动脉参数相似。
- 结构OCT显示GDM孕妇RNFL厚度降低或与对照相似,GCL厚度、内丛状层厚度和黃斑RNFL厚度组合降低。
- OCTA显示浅层和深层毛细血管丛血管密度在GDM中降低或与对照无显著差异,结果不一致。
- OCTA其余参数(脉络膜毛细血管血管密度、外层视网膜血管密度、全图像血管密度、中心凹无血管区面积、中心凹密度和脉络膜毛细血管血流面积)均无显著差异。
诊断标准与关键数值
- GDM诊断标准、视网膜评估方法和检查时孕周在各研究间存在显著异质性,未汇总诊断阈值或敏感度/特异度。
临床应用与阅片要点
- 阅片时可关注GDM孕妇视网膜静脉增宽和动静脉比降低,但需结合临床背景。
- OCT评估RNFL、GCL和内丛状层厚度变化可能有助于识别GDM相关视网膜结构改变,但证据不一致。
- OCTA浅层和深层毛细血管丛血管密度变化不恒定,解释时需谨慎。
局限性
- 各研究方法、视网膜参数、疾病严重程度、GDM诊断标准和检查孕周异质性大,未行荟萃分析。
- ROBINS-I V2评估显示6项研究偏倚风险为严重,4项为中等。
- 现有证据不一致,需大规模前瞻性研究确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To examine the differences in retinal structure and vasculature between women with gestational diabetes mellitus (GDM) and normoglycemic pregnant controls.
METHODS: This was a systematic review of the available literature on retinal assessment in pregnancies with GDM compared with non-GDM controls, conducted in PubMed, EMBASE via Ovid, The Cochrane Library and Scopus databases in November 2025, following an a-priori designed and prospectively registered protocol. Studies examining the retina using any non-interventional method of retinal assessment in women with GDM compared to non-GDM controls were identified. Potentially eligible studies included prospective and retrospective cohort, case-control and population-based studies, as well as randomized controlled trials. The Risk Of Bias In Non-randomized Studies of Interventions version 2 (ROBINS-I V2) tool was used to evaluate the risk of bias of the included studies. A meta-analysis was not performed due to considerable heterogeneity in the reported methods of retinal assessment, retinal parameters examined, disease severity, diagnostic criteria for GDM and gestational age at the time of retinal examination.
RESULTS: The electronic database search yielded 1326 results, of which 21 were eligible for full-text review and nine were included. Following citation screening for additional eligible studies, 10 studies were ultimately included in the systematic review. The methods of retinal assessment utilized in the included studies were cross-sectional and structural optical coherence tomography (OCT), optical coherence tomography angiography (OCTA) and retinal fundus photography. Each method examined various retinal structural and vascular parameters. Studies examining retinal vascular metrics using retinal fundus photography and cross-sectional OCT found similar retinal arteriolar parameters, increased retinal venular parameters and a reduced retinal arteriovenous ratio in women with GDM compared with normoglycemic controls. Studies utilizing structural OCT reported that the retinal nerve fiber layer (RNFL) thickness was decreased or similar in women with GDM vs non-GDM controls. Combinations of the ganglion cell layer (GCL) thickness, inner plexiform layer thickness and macular RNFL thickness were found to be lower in women with GDM. All studies reporting on other OCT parameters (acircularity index and retinal, macular and GCL thickness) found them to be similar between the two groups. The superficial and deep capillary plexus vessel densities, assessed using OCTA, were reported to be lower in women with GDM in some studies, whereas others found no significant difference between the two groups. For the remaining OCTA parameters (choriocapillaris vessel density, outer retinal vessel density, whole-image vessel density, foveal avascular zone area, foveal density and choriocapillaris flow area), no study identified significant differences between women with GDM and non-GDM controls. The ROBINS-I V2 tool found the risk of bias to be serious in six studies and moderate in four studies.
CONCLUSION: Existing studies provide inconsistent evidence to clearly establish retinal structural or functional changes in pregnancies complicated by GDM. Future large-scale prospective studies are required to confirm these findings and evaluate whether the retinal changes observed in GDM persist postpartum. Such evidence may clarify their potential role as biomarkers of cardiovascular insult severity and inform stratified surveillance. © 2026 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Kitmiridou D, Mitrogiannis I, Charakida M, et al. Retinal imaging in gestational diabetes mellitus: systematic review. Ultrasound Obstet Gynecol. 2026. PMID: 41956059. doi:10.1002/uog.70218