外肛括约肌缺损角度30°截断值的验证
本研究回顾性纳入850例绝经前女性,采用经会阴四维超声断层成像评估外肛括约肌缺损角度,并与肛门失禁症状关联。平均缺损角度与失禁及困扰评分相关性最强,ROC曲线提示30°为定义显著缺损的最佳截断值。
要点
- 经会阴超声断层成像上外肛括约肌平均缺损角度与肛门失禁显著相关。
- 30°可作为外肛括约肌显著缺损的截断值,与腔内超声经验标准一致。
- 评估时建议测量多个层面的平均缺损角度而非单层最大值。
核心结论
- 在绝经前女性中,经会阴超声断层成像所示外肛括约肌缺损角度与肛门失禁各项指标显著相关,平均缺损角度是最佳预测指标,ROC分析支持30°作为显著缺损的截断值。
研究设计与样本
- 采用四维经会阴超声获取肛管容积数据,离线行断层超声成像评估外肛括约肌,评估者对临床资料盲法。
- 参考标准为St Mark's失禁评分和肛门失禁视觉模拟困扰评分,采用单变量回归和ROC曲线分析。
关键影像表现/征象
- 断层超声成像上外肛括约肌缺损表现为高回声环结构中断,111例(13%)患者共368个层面可见缺损。
- 缺损角度平均32°(范围2-155°),平均最大缺损角度67°(范围14-167°),每例评估6个层面共5100次评估。
诊断标准与关键数值
- ROC曲线分析提示30°为定义显著外肛括约肌缺损的最佳截断值,该标准原用于腔内超声。
- 平均缺损角度与肛门失禁、St Mark's评分及困扰评分相关性最强(均P<0.001)。
- 肛门失禁见于133例(16%),St Mark's评分中位数10(四分位距6-14),困扰评分均值6.6(范围0-10)。
临床应用与阅片要点
- 经会阴超声评估外肛括约肌时建议测量多个层面的平均缺损角度,而非仅取最大角度。
- 报告可参考30°截断值提示显著缺损,并结合St Mark's评分和困扰评分综合判断临床意义。
- 注意腔内超声的30°标准可外推至经会阴断层超声成像,但需在报告中注明所用检查方式。
局限性
- 回顾性单中心研究,仅纳入绝经前女性以减少混杂,结论不能直接推广至绝经后人群。
- 部分患者肛管容积数据缺失(64例)或因病排除(1例),可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Obstetric anal sphincter injury is a common complication of childbirth and the primary etiological factor for anal incontinence in young women. On endoanal ultrasound, a significant defect of the external anal sphincter (EAS) has arbitrarily been defined as a gap of greater than 30° in its hyperechogenic ring structure. This study was designed to validate a cut-off value for defining a significant EAS defect on tomographic exoanal imaging.
METHODS: This was a retrospective study involving women attending a tertiary urogynecological unit between January 2015 and December 2021. Analysis was limited to premenopausal women to reduce confounders. The assessment included obtaining the St Mark's incontinence score and visual analog scale (VAS) bother score of anal incontinence, and performance of four-dimensional transperineal exoanal ultrasound. Tomographic ultrasound imaging (TUI) was used to evaluate the EAS; offline analysis was performed at a later date, with the assessor blinded against all other clinical data. The primary measure to assess EAS defects was defect angle. Associations between this parameter and anal incontinence, VAS bother score and St Mark's score were estimated using univariable logistic or linear regression models. Receiver-operating-characteristics (ROC)-curve analysis was performed to determine the optimal cut-off value of the EAS defect angle for defining a significant defect.
RESULTS: A total of 915 premenopausal women were seen during the study period. Ultrasound volumes of the anal canal were missing in 64 women and one patient was excluded due to muscular dystrophy, leaving 850 women included in the analysis. The mean age was 42 (range, 18-56) years and the mean body mass index was 29 (range, 16-57) kg/m2 at assessment. Anal incontinence was reported by 133 (16%) women, with a median St Mark's score of 10 (interquartile range, 6-14) and a mean VAS bother score of 6.6 (range, 0-10). On TUI, six slices were scored per patient (total of 5100 assessments). EAS defects were seen in 111 (13%) patients and 368 slices, with an average defect angle of 32° (range, 2-155°) and a mean maximum defect angle of 67° (range, 14-167°). Average defect angle showed the strongest correlation with anal incontinence, St Mark's score and VAS bother score (all P < 0.001). ROC-curve analysis suggested a cut-off of 30° for the definition of a significant EAS defect.
CONCLUSION: In premenopausal women, EAS defects on TUI were associated significantly with all investigated measures of anal incontinence. Average defect angle was the best predictor of anal incontinence and enabled ROC-curve analysis. The 30° defect angle criterion empirically used for endoanal ultrasound seemed to be valid as a cut-off for the diagnosis of significant anal sphincter defect on exoanal imaging. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Dietz HP, Shek KL, Descallar J, et al. Can we define a cut-off for external anal sphincter defect angle? Ultrasound Obstet Gynecol. 2026. PMID: 41955738. doi:10.1002/uog.70216
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。