文献速递妇产影像US

基于超声影像组学与机器学习的子宫肌瘤与腺肌瘤鉴别模型

Model Based on Ultrasound Radiomics and Machine Learning for Differentiating Uterine Fibroids and Adenomyomas.
PubMed 文献 · J Ultrasound Med · 2026-04-10

该研究回顾性纳入3家机构659例术后病理确诊的子宫肌瘤(422例)或腺肌瘤(237例)患者,基于超声影像组学特征构建SVM模型,并联合临床特征构建组合模型。组合模型在训练集和外部队列中AUC分别为0.923和0.894,优于临床模型和影像组学模型,可作为无创鉴别工具辅助术前规划与生育力保护决策。

要点

  • 超声影像组学SVM模型在外部测试集AUC为0.823,组合模型提升至0.894。
  • 组合模型校准曲线一致性良好,决策曲线显示最高整体临床获益。
  • 该无创工具可辅助子宫肌瘤与腺肌瘤的术前鉴别及生育力保护策略。

核心结论

  • 基于SVM的超声影像组学模型可有效鉴别子宫肌瘤与腺肌瘤,组合模型是可靠的无创鉴别工具。

研究设计与样本

  • 训练集来自机构1和机构2,外部测试集来自机构3。
  • 从超声图像提取影像组学特征,基于不同机器学习分类器开发模型,并联合影像组学特征与临床特征构建组合模型及列线图。
  • 采用AUC、校准曲线和决策曲线评估模型性能。

诊断标准与关键数值

  • 临床模型训练集AUC为0.767(95% CI: 0.7259-0.8082),测试集AUC为0.747(95% CI: 0.6003-0.8933)。
  • 基于SVM的影像组学模型训练集AUC为0.899(95% CI: 0.8721-0.9256),外部测试集AUC为0.823(95% CI: 0.7297-0.9159)。
  • 组合模型训练集AUC为0.923(95% CI: 0.9015-0.9451),外部测试集AUC为0.894(95% CI: 0.8285-0.9596)。

临床应用与阅片要点

  • 组合模型在训练集和外部测试集均显示优于临床模型和影像组学模型的鉴别效能。
  • 校准曲线提示组合模型预测概率与实际结果一致性良好,决策曲线显示其整体临床获益最高。
  • 该工具可辅助临床医生在术前区分子宫肌瘤与腺肌瘤,为术前规划和生育力保护策略提供参考。

局限性

  • 本研究为回顾性设计,可能存在选择偏倚。
  • 外部测试集仅来自单一机构,样本量有限,泛化能力需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the value of radiomics based on ultrasound in differentiating uterine fibroids (UFs) and uterine adenomyomas (AMs) and construct a noninvasive tool for this differentiation.

METHODS: The clinical data and ultrasound images of 659 patients diagnosed with UFs or AMs postoperatively were retrospectively analyzed at 3 institutions from January 2020 to December 2024. The cohort comprised patients with 422 UFs and 237 uterine AMs, divided into training (Institution 1 and Institution 2) and external test cohort (Institution 3). Radiomics features extracted from ultrasound images were used to develop models based on different machine learning classifiers. A combined model was developed combining radiomics features with clinical characteristics and a nomogram was depicted. The performance of the models was assessed by area under the receiver operating characteristic curve (AUC), calibration curve, and decision curve.

RESULTS: The clinical model demonstrated moderate performance with AUCs of 0.767 (95% CI: 0.7259-0.8082) in the training cohort and 0.747 (95% CI: 0.6003-0.8933) in the test cohort. The radiomics model based on the support vector machine (SVM) showed the best performance in discriminating UFs and AMs, with AUCs of 0.899 (95% CI: 0.8721-0.9256) in the training cohort and 0.823 (95% CI: 0.7297-0.9159) in the external test cohort, respectively. The combined model presented better efficacy compared with the clinical model and the radiomics model, with AUCs of 0.923 (95% CI: 0.9015-0.9451) and 0.894 (95% CI: 0.8285-0.9596) in the training and external test cohorts, respectively. The calibration curves suggested good consistency and decision curves showed the highest overall clinical benefit for the combined model.

CONCLUSIONS: Ultrasound radiomics model based on SVM is feasible to differentiate UFs and AMs, and the combined model is a reliable and effective noninvasive tool for differentiation between UFs and AMs, which can assist clinicians in preoperative planning and fertility preservation strategies.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Wu Q, Deng Y, Chen L, et al. Model Based on Ultrasound Radiomics and Machine Learning for Differentiating Uterine Fibroids and Adenomyomas. J Ultrasound Med. 2026. PMID: 41960942. doi:10.1002/jum.70253

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。