文献速递泌尿生殖MRUS

前列腺病灶尺寸多平面与轴位测量的一致性及其对PI-RADS v2.1分类和病理对照的影响

Multiplanar versus axial measurement of prostate lesion size: agreement and impact on PI-RADS v2.1 categorization and histopathologic correlation.
PubMed 文献 · Abdom Radiol (NY) · 2026-04-01

单中心回顾性研究纳入261个PI-RADS 4或5的前列腺病灶,比较最大轴位直径(MAD)与最大冠状位或矢状位直径(MCSD)测量。Bland-Altman分析显示两种测量偏差小、一致性高(平均差0.28 mm;95%一致性界限-2.62至3.19 mm),ICC=0.93;PI-RADS分类一致性几乎完美(κ=0.931)。仅1.74%病灶使用MCSD后从PI-RADS 4重分类为5,且所有重分类病灶病理均为临床显著前列腺癌。

要点

  • 轴位与冠状/矢状位测量前列腺病灶大小一致性极好,PI-RADS分类几乎完美一致。
  • 仅少数(1.74%)病灶因MCSD测量从PI-RADS 4重分类为5,均病理证实临床显著癌。
  • 对头尾方向拉长的病灶,建议加测矢状或冠状位最大径以完整评估肿瘤范围。

局限性

  • 单中心回顾性设计,可能存在选择偏倚。
  • 仅纳入PI-RADS 4或5病灶,结论不适用于低评分病灶。
  • 重分类病灶数量少,统计效能有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate whether measurement of prostate lesion size on sagittal or coronal imaging planes influences PI-RADS v2.1 categorization and histopathologic correlation compared with axial measurement.

METHODS: In this single-center retrospective study, 261 prostate lesions categorized as PI-RADS 4 or 5 underwent subsequent targeted MRI/TRUS fusion biopsy or prostatectomy. Lesion size was measured as maximal axial diameter (MAD) and maximal coronal or sagittal diameter (MCSD). Lesions were subsequently categorized according to PI-RADS v2.1 using these measurements. The agreement between MAD and MCSD was assessed using a Bland-Altman analysis. Measurement reliability and interobserver agreement were evaluated using intraclass correlation coefficients (ICC). Kappa statistics were used to assess agreement in PI-RADS categorization for clinically significant prostate cancer.

RESULT: Bland-Altman analysis demonstrated minimal bias and strong agreement between MAD and MCSD measurements for the whole prostate (mean difference 0.28 mm; 95% limits of agreement - 2.62 to 3.19 mm), with similar results in both the peripheral and transition zones. Intraclass correlation analysis showed excellent reliability between measurements (ICC = 0.93). Agreement in PI-RADS categorization between MAD and MCSD was almost perfect (κ = 0.931). Reclassification from PI-RADS 4 to 5 occurred in 1.74% of lesions when using MCSD, and all reclassified lesions demonstrated clinically significant prostate cancer on histopathology.

CONCLUSION: MAD and MCSD measurements of prostate lesion size demonstrate excellent agreement and highly concordant PI-RADS categorization. Although reclassification is uncommon, evaluation of the sagittal or coronal planes may provide additional value for selected lesions with craniocaudal elongation, where the maximal tumor extent may not be fully represented on axial images.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Chulroek T, Ariyasaksakul R. Multiplanar versus axial measurement of prostate lesion size: agreement and impact on PI-RADS v2.1 categorization and histopathologic correlation. Abdom Radiol (NY). 2026. PMID: 41922779. doi:10.1007/s00261-026-05484-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。