自动变形配准与三维边缘评估预测肺部热消融后局部复发
本研究为单机构回顾性研究,开发了肺特异性四阶段变形图像配准框架,用于量化108个消融肺肿瘤的三维消融边缘,并评估其与局部复发时间的关联。结果显示较大边缘与较长局部复发时间相关(亚分布风险比每毫米增加0.5,95%CI 0.4-0.6,P<.001),2mm边缘阈值下2年局部复发率为3%(95%CI 1-8),预测2年局部复发的AUC为0.86。
要点
- 四阶段肺优化变形配准框架平均目标配准误差为0.4mm±0.3,可实现自动三维消融边缘量化。
- 消融边缘每增加1mm,局部复发的亚分布风险比为0.5(95%CI 0.4-0.6,P<.001)。
- 以2mm为边缘阈值,2年局部复发率为3%(95%CI 1-8),预测2年局部复发的AUC为0.86。
核心结论
- 四步肺优化变形图像配准框架能够实现准确的自动三维肿瘤消融边缘量化,且边缘大小与局部复发时间相关。
研究设计与样本
- 经机构审查委员会批准的单机构回顾性研究,纳入69例患者(中位年龄59岁,IQR 50-69岁;38例女性)共108个消融肺肿瘤,采用术前和术后CT进行变形配准,使用自由形式B样条变换并以消融区为成本函数掩膜。
诊断标准与关键数值
- 平均目标配准误差为0.4mm±0.3,平均消融边缘为1.6mm±2.1;采用2mm边缘阈值时,2年局部复发率为3%(95%CI 1-8),预测2年局部复发的AUC为0.86;边缘每增加1mm的亚分布风险比为0.5(95%CI 0.4-0.6,P<.001)。
临床应用与阅片要点
- 该四阶段变形配准框架可用于自动量化三维消融边缘,边缘大小与局部复发时间相关,2mm阈值下2年局部复发率低,AUC为0.86。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To develop a lung-specific deformable image registration algorithm optimized for lung thermal ablation and evaluate whether three-dimensional (3D) margin assessment predicts time to local recurrence. Materials and Methods This institutional review board-approved, single-institution retrospective study evaluated patients who underwent lung thermal ablation with available pre- and postprocedural CT scans suitable for deformable registration. Images were preprocessed with segmentation of tumor, ablation zone, and lung. A four-stage deformable image registration framework was applied: (a) affine registration, (b) deformable image registration to the cropped lung, (c) lung mask-guided deformable image registration, and (d) local deformable image registration focused on the neighborhood adjacent to the ablation zone. Registrations were performed using free-form B-spline transformations with cost function masking of the ablation zone. Registration accuracy was assessed using target registration error (TRE). The 3D ablation margins were quantified using a distance-transform-based analysis of the spatial relationship between the tumor surface and ablation zone boundary. Associations between margin size and time to local recurrence were evaluated using competing-risks regression, and time-dependent receiver operating characteristic analysis was performed. Results A total of 69 patients (median age, 59 years [IQR, 50-69 years]; 38 female) with 108 ablated lung tumors were included. Mean TRE ± SD was 0.4 mm ± 0.3 and mean ablation margin was 1.6 mm ± 2.1. Larger margins were associated with longer time to local recurrence (subdistribution hazard ratio, 0.5 per millimeter increase [95% CI: 0.4, 0.6]; P < .001) and remained independently associated on multivariate analysis. Using a 2-mm margin threshold, the 2-year local recurrence rate was 3% (95% CI: 1, 8). The area under the receiver operating characteristic curve for predicting 2-year local recurrence was 0.86. Conclusion The four-step lung-optimized deformable image registration framework enabled accurate automated 3D tumor ablation margin quantification, and margin size was associated with time to local recurrence. Keywords: Ablation Techniques, Interventional-Oncology, Percutaneous, Thorax, Lung, Computer Applications-3D, Computational Studies, CT © RSNA, 2026.
引用
- Keshavamurthy KN, Salkin R, Shastri A, et al. Automated Deformable Registration and Three-dimensional Margin Assessment for Predicting Local Recurrence after Lung Thermal Ablation. Radiol Imaging Cancer. 2026. PMID: 41960995. doi:10.1148/rycan.250501
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。