文献速递头颈神经MR

腮腺内面神经分割:神经成像序列上手动分割的可重复性研究

Intraparotid Facial Nerve Segmentation: A Reproducibility Study of Manual Segmentation on Neurographic Sequences.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-10-29

本研究对7例单侧良性腮腺肿瘤患者的神经成像MRI数据,采用双回波稳态(DESS)和钆增强T1可变翻转角TSE(VFA-TSE)两种序列,由2名头颈影像学教师和2名影像学学员独立手动分割肿瘤侧与健康侧腮腺内面神经。结果显示神经干分割可重复性高,外周支仍然困难;VFA-TSE序列分割误差低于DESS序列但未达统计学显著;不同经验水平放射科医生间无显著差异。

要点

  • 腮腺内面神经干手动分割可重复性高,但外周支一致性低且更常出现未分割。
  • VFA-TSE序列神经干分割误差低于DESS序列,但校正多重比较后未达统计学显著。
  • 肿瘤邻近神经节段分割误差增大且观察者间变异性更高。

核心结论

  • 腮腺内面神经手动分割对神经干可重复,对外周支仍具挑战性;VFA-TSE可能较DESS在神经干勾画上有优势,而放射科医生经验水平似乎不限制分割可靠性。

研究设计与样本

  • 对7例单侧良性腮腺肿瘤患者的神经成像MR数据集进行可重复性研究,使用DESS和钆增强T1可变翻转角TSE(VFA-TSE)两种序列,由2名头颈影像学教师和2名影像学学员独立在3D Slicer中分割肿瘤侧与健康侧腮腺内面神经,因缺乏测量金标准,以平均配对误差、面神经分支观察者间分割一致性和沿神经走行的可靠性剖面量化分割可靠性,采用Wilcoxon符号秩检验并经Holm-Bonferroni校正比较序列、腺体状态和医生经验。

诊断标准与关键数值

  • 神经干平均配对误差1.58 mm(95%CI 1.38-2.04)。
  • 下干平均配对误差3.20 mm(95%CI 2.94-4.50)。
  • 上干平均配对误差3.58 mm(95%CI 2.29-5.99)。
  • VFA-TSE序列神经干平均配对误差1.26 mm(95%CI 0.84-2.10)vs DESS序列1.85 mm(95%CI 1.55-2.37),VFA-TSE较DESS降低,但校正多重比较后未达统计学显著。

局限性

  • 因缺乏测量标准,分割可靠性通过平均配对误差、观察者间分割一致性和可靠性剖面间接量化。
  • 进一步研究应优化神经成像序列并探索自动分割技术,以提高腮腺肿瘤术前规划的一致性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Preoperative delineation of the intraparotid facial nerve using advanced MR neurography may aid surgical planning of parotid tumors, reducing complications. However, the reliability of manual segmentation for depicting the nerve pathway has not been extensively investigated. This study aimed to assess the reproducibility of manual segmentation of the intraparotid facial nerve on neurographic MRI sequences.

MATERIALS AND METHODS: Neurographic MR data sets from 7 patients with unilateral benign parotid tumors were analyzed using 2 imaging sequences: double-echo steady-state (DESS) and T1 variable flip angle TSE (VFA-TSE) with gadolinium. Two faculty head and neck radiologists and 2 radiology trainees independently segmented the intraparotid facial nerve in both tumorous and healthy glands using 3D Slicer. Given the absence of a measurement standard, segmentation reliability was quantified through mean pair-wise error, interobserver segmentation agreement for anatomic nerve branches, and reliability profiles along the nerve course. Comparisons by imaging sequence, gland status, and radiologist experience were performed using Wilcoxon signed-rank tests with Holm-Bonferroni correction.

RESULTS: The mean pair-wise error was 1.58 [95% CI: 1.38-2.04] mm for the trunk, 3.20 [95% CI: 2.94-4.50] mm for the inferior division, and 3.58 [95% CI: 2.29-5.99] mm for the superior division. The VFA-TSE sequence showed lower pair-wise segmentation errors than the DESS sequence, particularly for the trunk (1.26 [95% CI: 0.84-2.10] mm vs 1.85 [95% CI: 1.55-2.37] mm), although no comparisons reached statistical significance after correction for multiple testing. Nerve segments near tumors exhibited increased segmentation errors and greater interobserver variability. No significant differences were observed between radiologists of differing experience. The trunk showed high interobserver agreement, whereas peripheral branches displayed lower consistency, more frequent nonsegmentation, and increased subdivision instances.

CONCLUSIONS: Manual segmentation of the intraparotid facial nerve is reproducible for the trunk but remains challenging for peripheral branches. VFA-TSE may offer an advantage over DESS for trunk delineation, whereas radiologist experience level does not appear to limit segmentation reliability. Standardized segmentation protocols can mitigate the impact of prior experience, but imaging sequence choice may influence segmentation reproducibility. Further research should refine the neurographic sequence and explore automated segmentation techniques to improve consistency in presurgical planning of parotid tumors.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Medrano-Martorell S, Pariente JC, Rodríguez Álvarez Y, et al. Intraparotid Facial Nerve Segmentation: A Reproducibility Study of Manual Segmentation on Neurographic Sequences. AJNR Am J Neuroradiol. 2026. PMID: 41974508. doi:10.3174/ajnr.A9348

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。