文献速递神经外周血管MR

颅内动脉瘤计算流体力学低壁面剪切应力与高分辨MR血管壁成像管壁强化的相关性

Correlation between computational fluid dynamics-derived low wall shear stress and vessel wall enhancement on high-resolution MR vessel wall imaging in intracranial aneurysms.
PubMed 文献 · Eur Radiol · 2026-04-04

回顾性分析49例49个未破裂颅内动脉瘤,比较CFD导出的低壁面剪切应力区域与高分辨MR血管壁成像强化灶的空间对应关系。强化灶与最近低壁面剪切应力位置的中位距离为0.55 mm(四分位距0.33-1.39 mm),以1.42 mm为参考阈值时49个动脉瘤中37个(75.5%)在此范围内。低壁面剪切应力位置与VWI炎性强化对应,支持低剪切应力与动脉瘤壁炎症相关的概念。

要点

  • VWI强化灶与CFD低壁面剪切应力位置中位距离0.55 mm,以1.42 mm为阈值时75.5%动脉瘤空间接近。
  • 低壁面剪切应力与VWI强化的空间接近性与动脉瘤大小(Spearman rho=0.243,p=0.093)及位置(p=0.667)无显著关联。
  • CFD导出的壁面剪切应力图可能作为无创预测动脉瘤壁炎症和评估不稳定性的方法。

核心结论

  • CFD低壁面剪切应力位置与VWI炎性强化对应,支持低剪切应力与动脉瘤壁炎症相关;CFD血流动力学分析可能作为无创预测血管壁炎症和评估动脉瘤不稳定性的方法。

研究设计与样本

  • 回顾性分析49例患者共49个未破裂颅内动脉瘤,均行对比增强高分辨VWI和血管造影成像;由认证神经放射科医师确定VWI最大瘤壁强化中心,重建患者特异性动脉瘤管腔用于CFD映射壁面剪切应力并提取低壁面剪切应力位置;以1.42 mm(采集体素对角线长度)为参考阈值划分接近与疏远,采用Spearman相关和Kruskal-Wallis检验评估距离与动脉瘤大小/位置的关系。

关键影像表现/征象

  • VWI强化灶与最近低壁面剪切应力位置的中位距离为0.55 mm(四分位距0.33-1.39 mm)。
  • 以1.42 mm为参考阈值,49个动脉瘤中37个(75.5%)表现为接近。
  • 壁面剪切应力-VWI接近性与动脉瘤大小无显著关联(Spearman rho=0.243,p=0.093)。
  • 壁面剪切应力-VWI接近性与动脉瘤位置无显著关联(p=0.667)。

诊断标准与关键数值

  • 以1.42 mm(采集体素对角线长度)为参考阈值,将VWI强化灶与最近低壁面剪切应力位置的三维欧氏距离分为接近与疏远。
  • 空间对应性量化为VWI强化灶与最近低壁面剪切应力位置之间的三维欧氏距离。

临床应用与阅片要点

  • 阅片时可关注VWI上动脉瘤壁强化灶与CFD低壁面剪切应力区域的空间对应关系,两者中位距离在亚毫米级。
  • 原文结论认为CFD壁面剪切应力图可能作为无创预测动脉瘤壁炎症和不稳定性的方法,并可能减少常规动脉瘤监测和治疗决策中对对比增强MRI的需求。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine whether regions of low wall shear stress (WSS) derived from computational fluid dynamics (CFD) spatially correspond to vessel wall imaging (VWI) enhancement in unruptured intracranial aneurysms.

MATERIALS AND METHODS: We retrospectively analyzed 49 patients with 49 unruptured intracranial aneurysms who underwent contrast-enhanced high-resolution VWI and angiographic imaging. A board-certified neuroradiologist identified the epicenter of maximal aneurysm wall enhancement on VWI. Patient-specific aneurysm lumens were reconstructed for CFD to map WSS on the aneurysm surface, and low-WSS locations were extracted on the sac. Spatial correspondence was quantified as the three-dimensional Euclidean distance between the VWI-enhancing focus and the nearest low-WSS location. A reference threshold of 1.42 mm (diagonal length of the acquisition voxel) was used to categorize close versus loose proximity. Associations between distance and aneurysm size/location were evaluated using Spearman correlation and the Kruskal-Wallis test.

RESULTS: The median distance between the VWI-enhancing focus and the low-WSS location was 0.55 mm (interquartile range: 0.33-1.39 mm). Using the 1.42-mm reference threshold, 37 of 49 aneurysms (75.5%) demonstrated proximity within this range. No significant associations were found between WSS-VWI proximity and aneurysm size (Spearman's rho = 0.243, p = 0.093) or location (p = 0.667).

CONCLUSIONS: Low-WSS locations on CFD correspond to inflammatory enhancement on VWI, supporting the concept that low shear stress is associated with aneurysm wall inflammation. CFD-based hemodynamic analysis may serve as a noninvasive method for predicting vessel wall inflammation and assessing aneurysm instability.

KEY POINTS: Question Detecting vessel wall inflammation in intracranial aneurysms requires specialized contrast MRI. Can CFD identify inflammatory regions noninvasively through low WSS mapping? Findings Low WSS regions from CFD closely corresponded to inflammatory enhancement on high-resolution MR VWI, showing submillimeter spatial agreement. Clinical relevance CFD-derived WSS mapping provides a noninvasive method to predict aneurysm wall inflammation and instability, potentially enabling earlier risk stratification and reducing the need for contrast-enhanced MRI in routine aneurysm surveillance and treatment decision-making.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Jung WS, Yang H, Choi JW, et al. Correlation between computational fluid dynamics-derived low wall shear stress and vessel wall enhancement on high-resolution MR vessel wall imaging in intracranial aneurysms. Eur Radiol. 2026. PMID: 41935243. doi:10.1007/s00330-026-12504-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。