文献速递神经外周血管MR

组织学验证的离体颈动脉斑块内出血与脂质成分定量磁敏感成像特征

Histologically Validated Ex Vivo Characterization of Intraplaque Hemorrhage and Lipid Components Using Quantitative Susceptibility Mapping.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-10-15

研究对24例颈动脉内膜切除术后离体斑块行3T MRI及定量磁敏感成像(QSM),经组织学验证比较斑块内出血(IPH)与脂质成分。常规MRI上IPH与富脂坏死核心(LRNC)的对比噪声比无显著差异,而QSM上IPH的相对磁敏感值高于LRNC和泡沫细胞聚集,提示QSM可提供常规MRI不具备的磁敏感信息。

要点

  • 常规T1WI和FLASH上IPH与LRNC的CNR无显著差异,信号重叠可能源于LRNC内红细胞残留。
  • QSM上IPH的相对磁敏感值高于LRNC和泡沫细胞聚集(P < .01),有助于区分二者。
  • 组织学发现许多LRNC含红细胞来源残留物,可解释其与IPH的常规MRI信号重叠。

核心结论

  • 组织学验证表明许多LRNC含红细胞残留,可能造成其与IPH在常规MRI上信号重叠;QSM可捕捉斑块内红细胞来源的磁敏感效应,提供常规MRI没有的补充磁敏感信息。

研究设计与样本

  • 离体研究,纳入2017年10月至2021年8月颈动脉内膜切除术中整块切除的24例颈动脉斑块标本,行3T离体MRI(T1WI、T2WI、TOF等效FLASH及多回波FLASH相位数据重建的QSM),并以H&E和免疫组化染色组织学为参考标准。

关键影像表现/征象

  • 常规T1WI或FLASH上IPH与LRNC的CNR无显著差异。
  • T1WI和FLASH上泡沫细胞聚集的CNR低于IPH(P < .05)。
  • T2WI上IPH的CNR低于LRNC或泡沫细胞聚集(P < .05)。
  • QSM上IPH的相对磁敏感值高于LRNC或泡沫细胞聚集(P < .01)。

诊断标准与关键数值

  • 常规MRI测量组织学对应区域的信号强度,以周围琼脂糖凝胶为参照计算对比噪声比(CNR)。
  • QSM测量同一区域的绝对磁敏感值,以斑块组织与周围琼脂糖凝胶的差值定义为相对磁敏感值(rSV)用于统计分析。
  • 共分析79个匹配横断面切片,包括24个IPH、61个LRNC和13个泡沫细胞聚集。

临床应用与阅片要点

  • 阅片时需注意常规T1WI和FLASH上IPH与LRNC信号可重叠,组织学显示许多LRNC含红细胞残留。
  • QSM测量的相对磁敏感值在IPH高于LRNC和泡沫细胞聚集,可作为补充磁敏感信息用于区分斑块成分。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Accurate characterization of carotid plaque components is essential for stroke risk assessment. Intraplaque hemorrhage (IPH) is a well-established marker of plaque vulnerability, whereas lipid-rich necrotic cores (LRNCs) often show overlapping signal characteristics with IPH on conventional MRI. The purpose of this study was to compare quantitative susceptibility mapping (QSM) with conventional MRI in differentiating IPH and lipid components in carotid plaques using ex vivo histologic validation.

MATERIALS AND METHODS: Twenty-four carotid plaque specimens obtained by en bloc excision during carotid endarterectomy between October 2017 and August 2021 were examined. All specimens underwent ex vivo MRI at 3T, including T1WI, T2WI, and TOF-equivalent FLASH, as well as QSM reconstructed from multiecho FLASH phase data. After MRI, specimens were serially sectioned and stained using H&E and immunohistochemical techniques. ROIs corresponding to histologically confirmed IPH and lipid components were delineated on MRI by consensus of 2 radiologists. On conventional MRI, signal intensities were measured in corresponding histologic regions, and contrast-to-noise ratios (CNRs) were calculated relative to surrounding agarose gel. On QSM, absolute magnetic susceptibility values were measured in the same regions. The difference between plaque tissue and the surrounding agarose gel was defined as the relative susceptibility value (rSV), which was used for statistical analysis. CNRs and rSVs among plaque components were compared using the Kruskal-Wallis test, followed by the Steel-Dwass test for pair-wise comparisons.

RESULTS: Seventy-nine matched cross-sectional slices were analyzed, yielding 24 IPH, 61 LRNCs, and 13 foam-cell aggregates (FAs). No significant difference in CNR was observed between IPH and LRNC on T1WI or FLASH. Histopathologic analysis demonstrated that many LRNCs exhibited erythrocyte-derived remnants consistent with prior hemorrhagic events. FAs showed lower CNRs than IPH on T1WI and FLASH (P < .05). On T2WI, IPH showed lower CNRs than LRNCs or FAs (P < .05). On QSM, IPH demonstrated higher rSVs than LRNCs or FAs (P < .01).

CONCLUSIONS: Histologic validation demonstrates that many LRNCs contain erythrocyte remnants, which may contribute to their overlapping signal characteristics with IPH on conventional MRI. QSM captures erythrocyte-derived susceptibility effects within plaques and provides complementary susceptibility-based information not available from conventional MRI.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Ishiyama A, Ishimaru H, Okano S, et al. Histologically Validated Ex Vivo Characterization of Intraplaque Hemorrhage and Lipid Components Using Quantitative Susceptibility Mapping. AJNR Am J Neuroradiol. 2026. PMID: 41951423. doi:10.3174/ajnr.A9335

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。