基于EPR评估炎症小鼠脑内钆基对比剂滞留及钆转螯合

EPR-based Assessment of Gadolinium-based Contrast Agent Retention and Gadolinium Transchelation in Inflamed Murine Brain.
PubMed 文献 · Invest Radiol · 2026-11-01

本研究采用电子顺磁共振(EPR)和电子-核双共振(ENDOR)技术,在小鼠多发性硬化模型及离体海马切片培养中,区分线性钆对比剂给药后脑内完整复合物结合的钆与解离释放的钆。结果显示炎症促进钆滞留,释放的钆周围存在含磷分子及无机配体结合,提示常规MRI可能低估钆沉积的真实程度,尤其在神经炎症条件下。

要点

  • EPR可在完整小脑活检组织中检测微摩尔级钆并区分复合物结合钆与释放钆。
  • 线性钆对比剂给药后,炎症促进小脑钆滞留,释放的钆微环境含磷分子。
  • 常规MRI可能低估钆积累的真实程度,尤其在神经炎症条件下。

核心结论

  • EPR和ENDOR是检测完整脑组织中钆离子释放及表征滞留钆形态的敏感方法;炎症促进钆滞留,常规MRI可能低估钆积累的真实程度,尤其在神经炎症条件下。

研究设计与样本

  • 动物实验研究:在小鼠多发性硬化模型体内给予线性钆喷酸二甲葡胺和宏环钆布醇后取亚毫米脑样本行EPR和ENDOR实验,并在炎症条件下离体器官型海马切片培养中验证;辅以质谱和MRI校准实验对加钆匀浆小鼠脑组织进行检测。

关键影像表现/征象

  • EPR在完整小脑活检和切片中检测到微摩尔级钆水平,并能区分线性钆对比剂给药后复合物结合钆与释放钆。
  • ENDOR在释放钆的微环境中检测到含磷分子。
  • 质谱和MRI校准实验在匀浆小鼠脑组织中证实钆与无机配体结合。

局限性

  • 原文指出常规MRI可能低估钆积累的真实程度,尤其在神经炎症条件下。
  • 原文强调需要整合体内和离体分析以阐明长期钆滞留机制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: In view of the mounting evidence for markedly increased cerebellar Gd retention under neuroinflammatory conditions after repeated linear GBCA administration in vivo , we aimed to discriminate between Gd retained within the GBCA complex and forms dissociated from the complex within the CNS and to characterize the chemical environment of the released Gd³⁺. For this purpose, we used electron paramagnetic resonance (EPR) spectroscopy, which enables direct detection of Gd³⁺ release and evaluation of its molecular surroundings in intact cerebellar tissue from inflamed and noninflamed brain sections exposed to either linear or macrocyclic GBCAs.

MATERIALS AND METHODS: We performed EPR and electron-nuclear double resonance (ENDOR) experiments on sub-mm brain samples taken after administration of linear gadopentetate-dimeglumine and macrocyclic gadobutrol in vivo in a murine multiple sclerosis model and ex vivo in organotypic hippocampal slice cultures under inflammatory conditions. Complementary mass spectrometry (MS) and MRI calibration experiments on Gd-spiked homogenized mouse brain tissue were used to identify potential Gd bindings and assess the relaxation-active fraction of retained Gd.

RESULTS: EPR detected µM range Gd levels in intact cerebellar biopsies and slices and distinguished between complex-bound and released Gd following linear GBCA administration in vivo . In biopsies, we detected by ENDOR phosphorus-containing molecules in the microenvironment of released Gd. Binding to inorganic ligands was evidenced using MS and MRI calibration experiments in homogenized mouse brain tissue.

CONCLUSIONS: EPR and ENDOR proved to be sensitive methods for detecting Gd³⁺ release and characterizing retained Gd species within intact brain tissue. Our findings demonstrate inflammation-promoted Gd retention, underscore the importance of integrating in vivo and ex vivo analyses to unravel mechanisms of long-term Gd retention, and suggest that conventional MRI may underestimate the true extent of Gd accumulation, especially under neuroinflammatory conditions.