指南与共识骨肌CTMRDRUS

哪些影像学检查方式、参数和诊断阈值最能定义髋关节不稳?来自范围综述和一项国际多学科德尔菲研究的共识声明

Which Imaging Modalities, Parameters, and Diagnostic Thresholds Best Define Hip Instability? Consensus Statements From a Scoping Review and an International Multidisciplinary Delphi Study.
指南 / 共识 · Clin Orthop Relat Res · 2026-03-19

该研究采用改良德尔菲技术,经两轮匿名投票(共识定义为同意率≥75%)形成27条关于髋关节不稳影像检查方式、参数和定量阈值的声明,其中81%(22/27)达成共识。共识认为X线(骨盆正位、假斜位、Dunn位)与MRI、CT是基础检查,LCEA<20°可诊断髋发育不良,20°–25°提示可能存在临床髋关节不稳,AWI<0.30、PWI<0.8、髋臼版本<5°或>30°为 endorsed 阈值;FEAR指数、新月征、前关节囊厚度和动态股骨头移位等未达成共识。

要点

  • X线(骨盆正位、假斜位、Dunn位)联合MRI和CT是评估髋关节不稳的基础影像检查。
  • LCEA<20°可诊断髋发育不良,LCEA 20°–25°提示可能存在临床髋关节不稳。
  • AWI<0.30、PWI<0.8、髋臼版本<5°或>30°为共识支持的定量阈值。

核心结论

  • 该国际德尔菲共识定义了评估髋关节不稳的核心影像学方法和阈值,在关键形态学参数和诊断阈值上达成一致,但较新的软组织和动态测量指标缺乏共识。

研究设计与样本

  • 采用改良德尔菲技术的共识研究,遵循ACCORD指南,经范围综述后形成27条声明,由多学科国际专家小组在结构化共识会议上经两轮匿名投票评估,共识定义为同意率≥75%。

诊断标准与关键数值

  • LCEA<20°被认为可诊断髋发育不良,而LCEA 20°–25°被认为提示可能存在临床髋关节不稳。
  • AWI<0.30、PWI<0.8、髋臼版本<5°或>30°为达成共识的定量阈值。
  • 81%(22/27)的声明达成共识。

临床应用与阅片要点

  • 对疑似临床髋关节不稳的患者,应使用标准X线作为一线影像检查,随后有针对性地使用CT和MRI评估三维骨形态和软组织稳定结构。
  • 影像表现应在分步骤的算法框架内解读,整合临床评估与多个互补的影像参数,而非依赖孤立的测量值。
  • 必须认识到,即使没有特征性影像学征象,髋关节不稳也可能存在。

局限性

  • 在较新的软组织和动态测量指标(如FEAR指数、新月征、前关节囊厚度和动态股骨头移位)上缺乏共识,凸显了未来研究的重要领域。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The diagnosis of hip instability remains challenging because of its multifactorial etiology and the variability of imaging practices across institutions. Hip instability refers to a clinical condition of insufficient osseous and/or soft tissue constraint with abnormal femoral head motion and symptoms, which may occur along a morphologic spectrum that overlaps with-but is not synonymous with-developmental dysplasia of the hip. Although numerous imaging modalities and imaging parameters have been proposed, there is limited consensus on which are most relevant, how they should be measured, and what diagnostic thresholds best correlate with instability. To address this gap, a Delphi consensus study with an international panel of experts to establish standardized clinical statements for the diagnostic criteria of hip instability was conducted.

QUESTIONS/PURPOSES: (1) What are the imaging modalities and protocols for investigating hip instability? (2) Which imaging parameters are most strongly associated with clinical hip instability? (3) What are the quantitative imaging thresholds for diagnosing hip instability?

METHODS: A consensus study using a modified Delphi technique was conducted in accordance with the Accurate Consensus Reporting Document (ACCORD) guideline. Following a scoping review, 27 statements addressing imaging modalities and protocols (question 1), imaging parameters associated with hip instability (question 2), and quantitative imaging thresholds (question 3) were developed. These statements were evaluated by a multidisciplinary international expert panel during a structured consensus meeting, with two rounds of anonymous voting and consensus defined a priori as ≥ 75% agreement. Consensus was achieved for 81% (22 of 27) of statements.

RESULTS: There was strong agreement that radiography (AP pelvis, false-profile, Dunn view) and MRI and CT constitute the foundational imaging modalities for the assessment of hip instability, whereas cartilage mapping techniques and dynamic ultrasound were considered adjunctive modalities with a more limited and evolving role. Radiographic measurements such as lateral center-edge angle (LCEA), anterior wall index (AWI), posterior wall index, and Tönnis angle reached consensus as key morphologic indicators. Several quantitative thresholds were endorsed. An LCEA of < 20° was considered diagnostic for hip dysplasia, a condition in which clinical hip instability is highly prevalent, whereas values between 20° and 25° were considered concerning for possible clinical hip instability. Additional thresholds included an AWI of < 0.30, PWI of < 0.8, and acetabular version < 5° or > 30°. In contrast, no consensus was reached for less-established imaging metrics such as the FEAR index, crescent sign, anterior capsule thickness, and dynamic femoral head translation.

CONCLUSION: This international Delphi consensus defined core imaging approaches and threshold values for the evaluation of hip instability. Although agreement was reached on key morphometric parameters and diagnostic thresholds, a lack of consensus exists around newer soft tissue and dynamic measures, highlighting important areas for future research.

CLINICAL RELEVANCE: In patients with suspected clinical hip instability, standard radiography should be used as the first-line imaging modality, followed by targeted use of CT and MRI to evaluate three-dimensional bony morphology and soft tissue stabilizers. Imaging findings should be interpreted within a stepwise, algorithmic framework that integrates clinical assessment with multiple complementary imaging parameters rather than relying on isolated measurements. Ultimately, accurate diagnosis of hip instability depends on the integration of findings from multiple modalities. Additionally, it must be recognized that hip instability may exist even in the absence of characteristic radiologic signs.

来源:Clin Orthop Relat Res,查看原文。版权归原作者所有。

引用

  1. Leopold VJ, Rakhra K, Spiker AM, et al. Which Imaging Modalities, Parameters, and Diagnostic Thresholds Best Define Hip Instability? Consensus Statements From a Scoping Review and an International Multidisciplinary Delphi Study. Clin Orthop Relat Res. 2026. PMID: 41926199. doi:10.1097/CORR.0000000000003905

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。