文献速递儿科影像技术与安全CT

儿科CT「频繁检查者」的累积剂量:队列结果与风险回顾

Cumulative dose in pediatric CT "frequent flyers": cohort results and risk review.
PubMed 文献 · Pediatr Radiol · 2026-03-31

该研究基于2013至2023年单中心剂量监测数据,统计10,199例0至19岁接受CT检查的患儿,其中97例(0.95%)累积有效剂量达到50 mSv阈值,20例(0.20%)达到100 mSv阈值;最高累积剂量见于严重及灾难性疾病、超重青少年、重复多期高剂量采集及CT引导介入操作。作者认为多数患儿仅接受1至2次CT,但高累积剂量组需密切关注。

要点

  • 本队列中97例(0.95%)患儿累积有效剂量达到50 mSv,20例(0.20%)达到100 mSv。
  • 最高累积有效剂量见于严重及灾难性疾病、超重青少年、重复多期高剂量采集及CT引导介入操作。
  • 多数患儿(89%)仅接受1至2次CT检查。

核心结论

  • 仅0.95%和0.20%的儿科患者因重复CT累积有效剂量超过50 mSv和100 mSv,但该群体常在整个童年期及之后继续累积剂量,值得密切关注。

研究设计与样本

  • 回顾性队列研究,基于本院剂量监测软件记录2013至2023年10,199例0至19岁接受CT检查的患者,统计累积有效剂量≥50 mSv和≥100 mSv者并分析最高剂量离群者的临床指征、累积吸收剂量分布及结局。

诊断标准与关键数值

  • 累积有效剂量阈值:≥50 mSv组97例(0.95%),达阈值时年龄16.0±3.0岁(中位数16.9岁);≥100 mSv组20例(0.20%),达阈值时年龄16.2±1.8岁(中位数16.5岁)。

临床应用与阅片要点

  • 本研究中心的做法是通过剂量监测软件记录所有CT患者的累积有效剂量,并对≥50 mSv和≥100 mSv者进行登记分析。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Published surveys have documented increasing cumulative radiation doses from the increased use of CT over recent decades, but pediatric data on this are sparse.

OBJECTIVE: To determine what percentage of pediatric patients receive a high cumulative effective dose (CED) from repeated CT scans in our practice, and to examine the reasons for this.

MATERIALS AND METHODS: Our dose monitoring software maintains a record of CED in all patients undergoing CT. Those who received a CED ≥50 mSv and ≥100 mSv were tabulated for further analysis. The highest dose outliers were flagged for analysis of clinical rationales of CT use, calculation of cumulative absorbed dose profiles, and outcomes.

RESULTS: From 2013-2023, we performed CT in 10,199 patients aged 0-19 years, of whom 75% had one, 14% had two, 5% had three, 3% had four, and 3% had five or more CTs. Of our cohort, 97 (0.95%) reached the CED dose threshold of 50 mSv at age 16.0±3.0 (16.9) years [mean±SD (median)], and 20 (0.20%) also reached the 100 mSv threshold at age 16.2±1.8 (16.5) years. The highest CED values occurred in patients with serious and catastrophic conditions, in overweight adolescents, and because of repeated high-dose multiphasic acquisitions and CT-guided interventions.

CONCLUSION: Most of our patients (89%) had only 1-2 CT scans. Although only 0.95% and 0.20% of our pediatric patients experienced CEDs more than 50 mSv and 100 mSv (respectively) from repeated CT scans, these groups deserve close attention, as they often continue to accumulate doses throughout childhood and beyond.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Westra SJ, Ferretti AE, Marschall TA, et al. Cumulative dose in pediatric CT "frequent flyers": cohort results and risk review. Pediatr Radiol. 2026. PMID: 41915041. doi:10.1007/s00247-026-06598-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。