该系统综述与Meta分析纳入11项研究,评估金属伪影减少序列(MARS)MRI对髋、膝、肩关节置换术后疑似假体周围关节感染(PJI)的诊断准确性,汇总敏感度0.88(95%CI 0.72-0.95)、特异度0.95(95%CI 0.80-0.99)、AUC 0.94;软组织改变亚组诊断表现最佳(敏感度0.82、特异度0.91),骨改变准确性较低。

要点

  • MARS-MRI诊断PJI汇总敏感度0.88、特异度0.95、AUC 0.94。
  • 软组织改变亚组诊断表现最佳(敏感度0.82、特异度0.91)。
  • 滑膜炎和积液次之,骨改变诊断准确性较低。

核心结论

  • MARS-MRI对假体周围关节感染具有高诊断准确性(敏感度0.88、特异度0.95、AUC 0.94),尤其以软组织改变表现最佳;有助于抗菌药物管理、减少不必要干预;需进一步开展大型多中心前瞻性研究以强化证据并验证临床效用。

研究设计与样本

  • 系统综述与Meta分析,遵循PRISMA-DTA和PRISMA 2020指南,纳入11项诊断准确性研究;检索PubMed、Embase、Scopus和Web of Science(2005年起,无语种限制);纳入≥18岁髋、膝或肩关节置换术后疑似感染或无菌性松动行MRI者;参考标准为MSIS或ICM标准、或术中微生物学与组织学。

诊断标准与关键数值

  • MARS-MRI诊断PJI的汇总敏感度0.88(95%CI 0.72-0.95)、特异度0.95(95%CI 0.80-0.99)、AUC 0.94;软组织改变亚组敏感度0.82、特异度0.91,诊断表现最佳;滑膜炎和积液次之;骨改变准确性较低。

临床应用与阅片要点

  • MARS-MRI对诊断PJI具有高诊断准确性,阅片时可关注软组织改变(诊断表现最佳),滑膜炎和积液次之,骨改变准确性较低;该检查有助于抗菌药物管理、减少不必要干预。

局限性

  • 需进一步开展大型多中心前瞻性研究以强化证据并验证临床效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Periprosthetic joint infection (PJI) remains one of the most serious. Advances in metal-artefact-reduction sequences (MARS) now allow for improved diagnostic quality imaging in the periprosthetic region. Early studies suggest the diagnostic efficacy of MARS, including subfeatures, yet no formal synthesis of available data exists.

METHODS: A systematic review and meta-analysis were conducted following PRISMA-DTA and PRISMA 2020 guidelines. Eligible studies include diagnostic accuracy studies reporting MARS-MRI compared with established reference standards, such as Musculoskeletal Infection Society (MSIS) or International Consensus Meeting (ICM) criteria, or intraoperative microbiology and histology. Adults (≥18 years) with hip, knee, or shoulder arthroplasty undergoing MRI for suspected infection or aseptic loosening were included. Comprehensive searches were conducted in PubMed, Embase, Scopus, and Web of Science, from 2005 onwards, without language restriction.

RESULTS: A total of 11 studies were included in this meta-analysis evaluating MARS-MRI for diagnosing periprosthetic joint infection (PJI). Pooled performance demonstrated high diagnostic accuracy with sensitivity 0.88 (95% CI 0.72-0.95), specificity 0.95 (95% CI 0.80-0.99), and AUC 0.94. Subgroup analysis showed soft tissue changes had the best diagnostic performance (sensitivity 0.82, specificity 0.91), followed by synovitis and effusion, whilst bone changes were less accurate. Overall, MARS-MRI demonstrates excellent utility in diagnosing PJI.

CONCLUSION: MARS-MRI demonstrates high diagnostic accuracy for periprosthetic joint infection (sensitivity 0.88, specificity 0.95, AUC 0.94), particularly with soft tissue changes. It aids antimicrobial stewardship by reducing unnecessary interventions. Further large, multi-centre prospective studies are needed to strengthen evidence and validate clinical utility.