胶原敏感双能CT作为肌腱病评估的定量工具:一项前瞻性诊断准确性研究
这项前瞻性研究纳入15例临床诊断为跟腱或髌腱肌腱病的患者,在基线和6个月时行双侧DECT和MRI检查,评估胶原敏感DECT定量评估负荷性肌腱病的效力并与MRI比较。DECT显示患腱胶原密度显著低于未患腱,ROC分析显示DECT(AUC=0.84)与MRI(AUC=0.80)诊断性能相当,DECT胶原密度与MRI信号强度呈强负相关(r=-0.83)。
要点
- 患腱DECT胶原密度显著低于未患腱(23.7±20.2 vs 60.2±29.6 HU,p<0.001)。
- DECT诊断性能与MRI相当(AUC 0.84 vs 0.80),且可定量胶原密度。
- DECT胶原密度与MRI信号强度呈强负相关(r=-0.83)。
核心结论
- 胶原敏感DECT为负荷性肌腱病的检测和评估提供可靠的定量方法,诊断能力与MRI相当,并可行胶原密度定量。
研究设计与样本
- 前瞻性诊断准确性研究,15例连续临床诊断为跟腱或髌腱肌腱病的患者,基线和6个月行双侧DECT和MRI,以ROC分析评估诊断准确性。
关键影像表现/征象
- DECT对应图上患腱胶原密度显著低于未患腱(23.7±20.2 vs 60.2±29.6 HU,p<0.001)。
- MRI显示病理区域信号强度增高。
- 随访时临床改善反映为两种影像模态的正常化趋势,但无统计学显著性。
诊断标准与关键数值
- DECT诊断肌腱病的AUC=0.84,MRI的AUC=0.80。
- DECT胶原密度与MRI信号强度呈强负相关(r=-0.83)。
局限性
- 随访时临床改善反映为两种影像模态的正常化趋势,但无统计学显著性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The purpose of this study was to evaluate the effectiveness of collagen-sensitive dual-energy computed tomography (DECT) as a quantitative imaging tool for the assessment and monitoring of load-induced tendinopathy in the Achilles and patellar tendons, comparing it to magnetic resonance imaging (MRI).
METHODS: In a prospective study, 15 consecutive patients clinically diagnosed with Achilles or patellar tendinopathy underwent bilateral DECT and MRI at baseline and 6 months. Quantitative measurements included collagen density assessed via DECT and signal intensity via MRI. Clinical symptoms were evaluated using numerical pain ratings and VISA-A/P scores. The diagnostic accuracy of both imaging modalities was assessed using ROC analysis, and correlations between DECT and MRI findings were investigated.
RESULTS: DECT revealed significantly lower collagen densities on corresponding maps in affected tendons (n = 18, 23.7 ± 20.2) compared to unaffected tendons (n = 12, 60.2 ± 29.6 HU, p < 0.001), whereas MRI demonstrated increased signal intensities in pathological regions. ROC analysis indicated comparable diagnostic performance for DECT (AUC = 0.84) and MRI (AUC = 0.80). A strong inverse correlation (r = -0.83) was observed between DECT-measured collagen densities and MRI signal intensities. Clinical improvements at follow-up were reflected by normalization trends in both imaging modalities, though not statistically significant.
CONCLUSIONS: Collagen-sensitive DECT provides a reliable quantitative approach for detecting and assessing tendon pathologies in load-induced tendinopathy, demonstrating diagnostic capabilities comparable to MRI while offering the possibility for collagen density quantification.
引用
- Diekhoff T, Kim S, Gwinner C, et al. Collagen-sensitive dual-energy-CT as a quantitative tool for tendinopathy assessment: a prospective diagnostic accuracy study. Skeletal Radiol. 2026. PMID: 41865099. doi:10.1007/s00256-026-05199-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。