文献速递头颈技术与安全CTUS

术前超声联合4DCT可提高放射科医生识别功能亢进甲状旁腺的置信度

Addition of Preoperative Ultrasound to 4DCT Increases Radiologist Confidence in Identifying Hyperfunctioning Parathyroid Glands.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-10-01

该回顾性研究纳入80例原发性甲状旁腺功能亢进患者,均行4DCT和超声检查后接受治愈性甲状旁腺切除术。每例分别由不同神经放射科医生单独用4DCT及4DCT联合超声阅片两次。联合超声使敏感度从88.3%升至91.5%但无统计学意义,定位准确率仍高,放射科医生置信度显著提高。

要点

  • 4DCT联合超声较单独4DCT提高放射科医生诊断置信度。
  • 联合超声敏感度88.3%升至91.5%但无统计学显著差异。
  • 联合超声在提高高置信度真阳性的同时也增加高置信度假阳性。

核心结论

  • 在本队列中,4DCT联合超声未显著提高定位准确率,但大幅提高放射科医生置信度。

研究设计与样本

  • 回顾性研究,纳入80例原发性甲状旁腺功能亢进患者,均行4DCT和超声检查后接受治愈性甲状旁腺切除术。
  • 每例由不同神经放射科医生分别单独用4DCT及4DCT联合超声阅片两次,记录病灶位置和5点Likert量表诊断置信度。
  • 以手术和病理结果为参考标准判定定位准确性。

关键影像表现/征象

  • 4DCT联合超声组放射科医生置信度高于单独4DCT组。
  • 联合技术增加高置信度真阳性,同时也增加高置信度假阳性。
  • 联合超声对下位腺体和大病灶获益最大。

诊断标准与关键数值

  • 94个异常腺体中,单独4DCT敏感度88.3%,4DCT联合超声敏感度91.5%,差异无统计学意义,两种方法准确率均保持高位。
  • 联合技术降低若干亚组中高置信度判读的阳性预测值。
  • 小病灶和甲状腺肿患者中,敏感度提高与阳性预测值降低的权衡最为明显。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: 4D CT (4DCT) is a key imaging technique for preoperative localization of parathyroid adenomas in primary hyperparathyroidism. Ultrasound (US) is frequently added with the assumption that it enhances diagnostic performance. This study aimed to determine whether incorporating US into a 4DCT-based evaluation improves diagnostic accuracy and to assess its impact on radiologists' diagnostic confidence.

MATERIALS AND METHODS: In this retrospective study, we reviewed 80 patients with primary hyperparathyroidism who underwent both 4DCT and US followed by curative parathyroidectomy. Each case was reviewed twice, once with 4DCT alone and once with 4DCT plus US, by different neuroradiologists who recorded lesion location and diagnostic confidence using a 5-point Likert scale. Localization accuracy was determined by comparing imaging findings with operative and pathology results. Diagnostic performance was assessed on per-patient and per-lesion bases, with subgroup analyses evaluating gland location, thyroid characteristics, streak artifact, lesion size, and presence of goiter. Paired statistical tests compared performance between modalities.

RESULTS: Among 94 abnormal glands, sensitivity increased modestly with the addition of US (88.3%-91.5%) without statistical significance, and accuracy remained high for both approaches. Radiologist confidence was higher in the combined 4DCT plus US group compared with the 4DCT-alone group. Although the combined technique increased high-confidence true-positives, it also increased high-confidence false-positives. This reduced the positive predictive value of high-confidence calls in several subgroups. The addition of US to 4DCT provided the greatest benefit for inferior glands and larger lesions, whereas the trade-off between improved sensitivity and reduced positive predictive value was most pronounced in technically challenging scenarios, including smaller lesions and patients with goiter.

CONCLUSIONS: In this cohort, adding US to 4DCT did not significantly improve localization accuracy but did substantially increase radiologist confidence.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Mohammadi S, Cunnane ME, Juliano AF, et al. Addition of Preoperative Ultrasound to 4DCT Increases Radiologist Confidence in Identifying Hyperfunctioning Parathyroid Glands. AJNR Am J Neuroradiol. 2026. PMID: 41881570. doi:10.3174/ajnr.A9306

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。