文献速递乳腺乳腺X线

乳腺X线摄影报告中是否应披露人工智能结果:患者对一致与不一致判读反应的随机调查研究

Should AI results be disclosed in mammography reports? A randomised survey study of patient responses to concordant and discordant interpretations.
PubMed 文献 · Eur Radiol · 2026-03-15

在意大利米兰两家学术中心对600名接受乳腺X线摄影的女性进行横断面随机实验调查,随机分为四组假设性BI-RADS 1场景。披露不一致的人工智能假阳性结果显著降低对放射科医生的信任、增加焦虑、寻求第二意见和考虑法律行动,附加解释说明可显著减轻这些不良效应。

要点

  • 披露人工智能与放射科医生判读不一致的假阳性结果会降低患者信任并增加焦虑与法律顾虑。
  • 在报告中附加解释说明可显著减轻不一致结果引起的不良情绪和行为反应。
  • 各场景下患者对人工智能的认可度均保持在85%以上。

核心结论

  • 披露不一致的人工智能结果会降低信任并增加焦虑、寻求第二意见和法律顾虑,附加情境化解释说明可减轻这些不良情绪和行为反应,支持其作为人工智能整合乳腺X线摄影中的沟通策略。

研究设计与样本

  • 横断面随机实验调查,纳入2023年1月至2024年1月在意大利米兰两家学术中心接受乳腺X线摄影的600名女性(平均年龄55.4±6.8岁),随机分为放射科医生单独组、人工智能无标记组、人工智能标记组和人工智能标记加解释组四个假设性BI-RADS 1场景。

诊断标准与关键数值

  • 披露不一致的人工智能结果较放射科医生单独组降低对放射科医生的信任(73.0 vs 90.1,p < 0.001)。
  • 人工智能标记组较放射科医生单独组焦虑比例为58.0% vs 16.0%(OR = 15.4)。
  • 人工智能标记组较放射科医生单独组寻求第二意见比例为50.0% vs 8.7%(OR = 10.2)。
  • 人工智能标记组较放射科医生单独组考虑法律行动比例为60.7% vs 38.7%(OR = 2.49)。
  • 附加解释说明后焦虑比例为25.3%(OR = 0.26),人工智能标记加解释组较放射科医生单独组焦虑仅轻度增加(p = 0.04)且信任无显著降低(p = 0.42)。

临床应用与阅片要点

  • 作者认为,在乳腺X线摄影报告中提供关于人工智能局限性的清晰背景说明可减轻患者焦虑、增强对放射科医生的信任并减少不必要的随访和潜在医疗法律行动。
  • 作者认为,情境化披露人工智能结果可作为人工智能整合乳腺X线摄影中的沟通策略。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess how disclosing artificial intelligence (AI) results, particularly discordant findings, affects patient trust, anxiety, follow-up intentions, and attitudes toward AI in mammography. The study also assessed whether adding an explanatory note mitigates adverse reactions.

MATERIALS AND METHODS: A cross-sectional randomised experimental survey was conducted among 600 women (mean age 55.4 ± 6.8 years) undergoing mammography in two academic centres in Milan, Italy, between January 2023 and January 2024. Participants were randomised into four hypothetical BI-RADS 1 scenarios: Radiologist Only (control), AI No-Flag (AI concordant with radiologist), AI Flagged (AI discordant false-positive), and AI Flagged + Explanation (discordant AI with contextual information). Primary outcomes included trust (0-100 scale), worry, second-opinion intent, legal action intent, and AI approval. Analyses involved ANOVA, chi-square tests, and logistic regression with Bonferroni correction.

RESULTS: Disclosure of a discordant AI result significantly reduced trust in the radiologist (73.0 vs 90.1; p < 0.001), and increased anxiety (58.0% vs 16.0%; OR = 15.4), second-opinion intent (50.0% vs 8.7%; OR = 10.2), and legal action consideration (60.7% vs 38.7%; OR = 2.49). Adding explanatory context significantly mitigated these effects (e.g., anxiety: 25.3%; OR = 0.26). Compared to the Radiologist Only scenario, the AI Flagged + explanation scenario showed only a modest increase in anxiety (p = 0.04) and no significant trust reduction (p = 0.42). AI approval remained high (> 85%) across all groups.

CONCLUSION: Disclosing discordant AI results reduces trust and increases anxiety, second-opinion intent, and legal concerns. Contextualised disclosure of AI results mitigates adverse emotional and behavioural responses, supporting its use as a communication strategy in AI-integrated mammography.

KEY POINTS: Question Current guidelines lack clear recommendations on disclosing AI-generated mammography findings, creating uncertainty about patient trust, anxiety, and medicolegal implications of discordant results. Findings Disclosing discordant AI mammography findings reduced patient trust, increased anxiety, second-opinion seeking, and litigation intent; adding contextual explanations significantly mitigated these adverse effects. Clinical relevance Providing clear context about AI limitations in mammography reports mitigates patient anxiety, enhances trust in radiologists, and reduces unnecessary follow-up and potential medicolegal actions, supporting optimal patient communication during clinical implementation of AI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Pesapane F, Depretto C, Rotili A, et al. Should AI results be disclosed in mammography reports? A randomised survey study of patient responses to concordant and discordant interpretations. Eur Radiol. 2026. PMID: 41832929. doi:10.1007/s00330-026-12405-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。