文献速递乳腺MR

基于嵌套交叉验证的三层MRI影像组学模型术前预测乳腺癌腋窝淋巴结转移

Preoperative Prediction of Axillary Lymph Node Metastasis in Breast Cancer Using a Three-tier MRI Radiomics Model with Nested Cross-validation.
PubMed 文献 · Acad Radiol · 2026-03-05

回顾性纳入2018年7月至2024年8月494例经病理确诊乳腺癌并于术前行动态对比增强(DCE)和T2FS-STIR序列MRI的患者,构建临床、定性MRI和影像组学特征的三层递进模型。模型3的AUC(0.769,95%CI:0.724-0.808)显著高于模型1(0.676,95%CI:0.626-0.722;ΔAUC=+0.093,p<0.001)和模型2(0.735,95%CI:0.686-0.776;ΔAUC=+0.034,p=0.002),Bonferroni校正(α=0.017)后仍显著。

要点

  • 模型3纳入临床、定性MRI和DCE/T2FS影像组学特征,术前预测腋窝淋巴结转移AUC为0.769。
  • SHAP分析显示T2FS来源影像组学(平均|SHAP|=0.811)和DCE来源影像组学(平均|SHAP|=0.492)为最重要预测因子。
  • 低风险组阴性预测值71.5%(95%CI:63.2%-78.8%),高风险组阳性预测值80.2%(95%CI:73.9%-85.4%)。

核心结论

  • 三层MRI影像组学模型显著提高术前腋窝淋巴结转移预测性能,嵌套交叉验证方法为潜在临床实施提供可信的性能估计。

研究设计与样本

  • 回顾性研究,纳入494例经病理确诊乳腺癌并于2018年7月至2024年8月术前行DCE和T2FS-STIR序列MRI的患者。

诊断标准与关键数值

  • 模型3的AUC为0.769(95%CI:0.724-0.808),显著高于模型1的0.676(95%CI:0.626-0.722;ΔAUC=+0.093,p<0.001)和模型2的0.735(95%CI:0.686-0.776;ΔAUC=+0.034,p=0.002),Bonferroni校正(α=0.017)后仍显著。

临床应用与阅片要点

  • 模型3可用于术前预测乳腺癌腋窝淋巴结转移,低风险组阴性预测值71.5%(95%CI:63.2%-78.8%)和高风险组阳性预测值80.2%(95%CI:73.9%-85.4%)可辅助风险分层。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop and validate a three-tier model incorporating clinical, qualitative magnetic resonance imaging (MRI), and radiomics features for preoperative prediction of axillary lymph node (ALN) metastasis in breast cancer, using nested cross-validation to ensure unbiased performance estimates.

MATERIALS AND METHODS: This retrospective study included 494 patients with pathologically confirmed breast cancer who underwent preoperative MRI (dynamic contrast-enhanced [DCE] and T2FS-STIR sequences) between July 2018 and August 2024. Three progressive models were developed as follows: Model 1 (clinical variables: age, tumor size, estrogen receptor, progesterone receptor, and human epidermal growth factor receptor 2), Model 2 (Model 1 + qualitative MRI features: peritumoral edema, time-intensity curve pattern, multifocality, field strength), and Model 3 (Model 2 + radiomics scores from DCE and T2FS sequences). Radiomics features were extracted using PyRadiomics and selected through variance-correlation-univariate-LASSO filtering. True nested five-fold cross-validation repeated three times ensured that feature selection and model training were performed independently within each training fold. Model performance was compared using Delong test with Bonferroni correction. SHAP analysis provided model interpretability.

RESULTS: Model 3 achieved significantly higher AUC (0.769, 95% CI: 0.724-0.808) compared to Model 1 (0.676, 95% CI: 0.626-0.722; ΔAUC = +0.093, p<0.001) and Model 2 (0.735, 95% CI: 0.686-0.776; ΔAUC = +0.034, p = 0.002). All comparisons remained significant after Bonferroni correction (α = 0.017). Feature selection demonstrated moderate stability, with 26.8 ± 4.0 (range: 16-32) DCE and 30.8 ± 4.3 (range: 25-38) T2FS features selected per fold. SHAP analysis revealed T2FS-derived radiomics (mean |SHAP| = 0.811) and DCE-derived radiomics (mean |SHAP| = 0.492) as the most important predictors. Bootstrap validation confirmed model stability (optimism = +0.001). The model showed good calibration (Brier score = 0.201). Decision curve analysis demonstrated clinical utility across threshold probabilities 0.20-0.60. Risk stratification achieved negative predictive value of 71.5% (95% CI: 63.2%-78.8%) for low-risk and positive predictive value of 80.2% (95% CI: 73.9%-85.4%) for high-risk groups.

CONCLUSION: The three-tier MRI radiomics model significantly improves preoperative ALN metastasis prediction. The nested cross-validation approach ensures credible performance estimates for potential clinical implementation.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Li H, Huang W, Liang J, et al. Preoperative Prediction of Axillary Lymph Node Metastasis in Breast Cancer Using a Three-tier MRI Radiomics Model with Nested Cross-validation. Acad Radiol. 2026. PMID: 41786550. doi:10.1016/j.acra.2026.02.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。