评估乳腺MRI图像质量:bMRI-QUAL评分系统
本研究开发了针对乳腺MRI标准协议的bMRI-QUAL质量评分系统,由两名独立读者对133例连续1.5-T检查进行4分制序列评分并加权计算0–10分全局评分,结果显示该系统可重复性好,约80%的检查图像质量良好至优秀,平均评估时间3分钟。
要点
- bMRI-QUAL采用0–10分全局评分,<6分视为图像质量不足,各序列按临床相关性加权。
- 两名读者平均全局评分为8.3±1.0,102/133例(76.7%)均获≥7分。
- 仅1例(0.8%)被两名读者均评为<6分,平均评估时间3分钟。
核心结论
- bMRI-QUAL是可重复的乳腺MRI质量评分系统,在该三级癌症中心约80%的病例图像质量良好至优秀。
研究设计与样本
- 开发bMRI-QUAL评分系统,由两名具有3年经验的独立读者评估133例连续1.5-T乳腺MRI检查,样本量计算以确保可重复性。
诊断标准与关键数值
- 每个序列按4分制评分:0=不可诊断;1=相关伪影但诊断价值保留;2=轻微伪影但诊断价值保留;3=图像质量优秀;加权公式为(T2加权×1)+(b=0扩散加权成像×0.5)+(表观扩散系数图×0.5)+(T1加权增强前×1)+(T1加权增强后×2)+(T1加权减影×3),总和除以2.4得到0–10分全局评分,<6分视为不足。
临床应用与阅片要点
- bMRI-QUAL提供相对快速且可重复的乳腺MRI图像质量评估,各序列按其对病灶检测/表征的临床相关性加权,可支持关于图像质量不足的决策并促进质量保证方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The performance of breast MRI (bMRI) depends on image quality, varying due to patient-related or technical/protocol factors. The resulting artifacts can heavily reduce sensitivity and specificity. We developed a bMRI quality scoring system (bMRI-QUAL) for the bMRI standard protocol.
MATERIALS AND METHODS: Two independent readers with 3 years of experience evaluated 133 consecutive 1.5-T examinations (sample size calculated to ensure reproducibility). Each sequence was rated on a 4-point scale: 0 = not diagnostic; 1 = relevant artifacts with conserved diagnostic value; 2 = slight artifacts with conserved diagnostic value; 3 = excellent image quality. Each score was weighted in the following formula: (T2-weighted * 1) + (diffusion weighted imaging with b = 0 * 0.5) + (apparent diffusion coefficient maps * 0.5) + (T1-weighted-precontrast * 1) + (T1-weighted-postcontrast * 2) + (T1-weighted-subtracted * 3). This sum was divided by 2.4, obtaining a 0-to-10 global score (GS), with < 6 considered insufficient.
RESULTS: The average GS between the two readers was 8.3 ± 1.0, with 102/133 examinations (76.7%) receiving a score ≥ 7 from both readers. Only one case (0.8%) was scored < 6 by both readers. The Bland-Altman analysis showed bias of -0.12, with limits of agreement ranging from -2.52 to +2.29. The difference in GS between the two readers (coverage probability) was 72/133 (54.1%) within ±1 and 123/133 (92.5%) within ±2. Coverage probability within ±1 point ranged from 94.0% to 99.2% across sequences. Average evaluation time/examination was 3 min.
CONCLUSIONS: bMRI-QUAL is a reproducible quality scoring system. Breast MRI image quality at a tertiary cancer center was good to excellent in approximately 80% of cases.
KEY POINTS: QuestionBreast MRI image quality varies widely and can compromise diagnostic accuracy. A standardized, clinically weighted scoring system is needed to guide repeat-scan decisions and facilitate quality assurance. FindingsIn 133 breast MRIs, the bMRI-QUAL 0-to-10 scoring system proved to be reproducible. Readers assigned a good-to-excellent mean score (8.3) with a 3-min evaluation time. Clinical relevancebMRI-QUAL provides a relatively fast and reproducible evaluation of breast MRI image quality, with each sequence weighted according to its clinical relevance for lesion detection/characterization. It can support decision-making regarding insufficient image quality and facilitate quality assurance protocols.
引用
- Marziali S, Corradini L, Depretto C, et al. Assessing breast MRI image quality: the bMRI-QUAL scoring system. Eur Radiol. 2026. PMID: 41824041. doi:10.1007/s00330-026-12439-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。