基于深度学习降噪的低剂量CT联合CT脂肪分数分析软件自动定量肝脂肪变
回顾性分析125例活体肝移植供体候选者,以MRI质子密度脂肪分数(MRI-PDFF)为参考标准,评估CT脂肪分数(CDFF)软件在模拟50%、25%、10%辐射剂量下的准确性,并分析深度学习降噪重建(DLDR)对低剂量CT中CDFF准确性的影响。全剂量CDFF与MRI-PDFF中度相关(r=0.728),诊断肝脂肪变AUC为0.82;低剂量下相关性降低,DLDR可改善CDFF准确性。
要点
- 全剂量CDFF与MRI-PDFF中度相关(r=0.728),诊断肝脂肪变AUC为0.82。
- 辐射剂量降低时CDFF相关性下降(r=0.684-0.725),10%剂量下诊断性能下降。
- DLDR可提升低剂量CDFF准确性(r=0.725-0.736),改善与MRI-PDFF的一致性。
核心结论
- CDFF准确性随辐射剂量降低而下降,但DLDR可提升准确性,尤其在低剂量下改善与MRI-PDFF的一致性。
研究设计与样本
- 回顾性分析2016年7月至2017年12月125例活体肝移植供体候选者,均行非增强CT和MRI检查。
诊断标准与关键数值
- 以MRI-PDFF≥5%为肝脂肪变诊断标准;全剂量CDFF与MRI-PDFF相关系数r=0.728(P<.001),诊断肝脂肪变ROC AUC为0.82。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the accuracy of CT-derived fat fraction (CDFF) software for quantifying hepatic steatosis at various radiation doses, using MRI-derived proton density fat fraction (MRI-PDFF) as the reference standard, and examines the impact of deep learning (DL)-based noise reduction on CDFF accuracy in low-dose CT (LDCT) scans.
METHODS: We conducted a retrospective analysis of 125 living liver donor candidates who underwent non-contrast CT and MRI between July 2016 and December 2017. CDFF was measured on full-dose and simulated LDCT scans at 50%, 25%, and 10% radiation doses. DL-based denoising reconstruction (DLDR) was applied to LDCT scans for CDFF recalculation. The accuracy of CDFF was compared with MRI-PDFF using Pearson correlation coefficients and receiver operating characteristic (ROC) curve analysis, focusing on the effects of radiation dose and DLDR.
RESULTS: Of the 125 participants (mean age 38 ± 10 years; 77 males), 29 (23%) had hepatic steatosis (MRI-PDFF ≥5%). Full-dose CDFF showed moderate correlation with MRI-PDFF (r = 0.728; P < .001). Correlation decreased with lower doses (r = 0.684-0.725) but improved with DLDR (r = 0.725-0.736). ROC AUC for diagnosing hepatic steatosis was 0.82 for full-dose CDFF, with similar performance across other doses except 10%.
CONCLUSIONS: CDFF accuracy declines at lower radiation doses, but DLDR enhances accuracy, improving alignment with MRI-PDFF, especially at reduced doses.
ADVANCES IN KNOWLEDGE: DLDR significantly enhances the accuracy of CDFF accuracy at lower radiation doses, enabling high diagnostic performance for hepatic steatosis while potentially reducing patient radiation exposure.